Sheila, Elenna, Jenne
Morning locking notes
At this time we held in down to allow relay tube work, and used the time to measure the oplev damping and try switching to using M3 wit for lower stage damping instead.
I measured the oplev damping OLGs, pitch and yaw. The reference traces use the oplev as the sensor for the damping, and the live traces use the M3 wit as the sensor but a different matrix value that Sheila calculated based on this alog.
We then switched to M2 damping using M3 wits as the sensor, and compared the BS spectra with no lower stage damping, oplev damping, and wit damping, comparison here. We see good suppression of the modes and less sensor noise injection on the M3 wits.
Here is a screenshot of the "OLDAMP" settings we want to use on M2. I want to clarify that even though we are now using the M3 wits as the sensor, the damping is still running through the oplev damping bank on M2.
At this point, we decided to break further and allow Filiberto to update the resistors on the M1 QOSEMs, so our lockloss transient from saturation is reduced.
***
After Fil and Oli finished the sat amp changes, we began locking again. We locked PRMI with M3 wit damping engaged before the triggering occurred so there was no lockloss. Once locked, the guardian disengages the lower stage damping.
Sheila measured the BS motion using oplev and M3 wit without the L2P decoupling engaged but the wit damping off. She checked the MICH and PRCL OLGs and we saw that they were fine. MICH UGF is 8.5 Hz, PRCL is 60 Hz.
I engaged the L2P decoupling, and we saw that low frequency pitch motion was reduced. However, there was still a large 0.45 Hz peak. With the M3 wit damping reengaged, the peak is reduced. See plot
Recipe for successful PRMI: M3 wit damping engaged, L2P decoupling engaged. Once we can reengage MICH ASC, we can turn off the M3 wit damping. I have SDFed the filters for BBSS M2 L2P decoupling 1 2
There is a lot of alignment drift in BS yaw while we sit locked. I had to touch up the aligment by hand.
We stayed in PRMI for 25 minutes.
***
We struggled to lock DRMI, and eventually chose to relock PRMI and fix the alignment. After this, DRMI locked quickly. We lost lock at the 3 f transition, so Sheila went to check we were aligned to REFLAIR 3f diodes. Then, I rephased the diodes while locked in PRMI by injecting a PRCL line and maximizing the height in 27 I, and a MICH line to maximize the height in 135 Q. PRCL, MICH, SDF
With DRMI locked, we saw that the PRCL OLG looked strange, so I also checked the REFLAIR 1f phasing. I made a minimal change to reflair 9 to improve PRCL in I and a 50 deg change in 45 to reduce SRCL in 45 Q. PRCL, SRCL, SDF
Sheila's guardian changes, to improve some problems we faced when locking.
***
Jenne and I attempted to check the PRCL/SRCL decoupling in the LSC matrix, and measured a value by injecting a PRCL line into reflair 9 and 45. However, the resulting OLGs looked even worse. Both PRCL and MICH look very strange, possibly indicating cross coupling. Unfortunately I don't have images of the PRCL transfer function but here is the MICH tf.
Seems like the phasing is wrong, but the loops became more unstable when we reverted the phasing changes I made earlier.
[Gabriele, Jenne]
Gabriele pointed out that the funny MICH OLG almost looks like a strange situation with the BBSS crossover. We tried changing the H1:SUS-BS_M3_DRIVEALIGN_L2L_GAIN from nominal 1, to 0.5 and also 2. This changed the high frequency part of the MICH OLG, but never made it 'better'.
I tried measuring the BBSS M2/M3 crossover, using a template I found in Elenna's directory that looks like it's from alog 91713. Her references from no-arm MICH-only are the green squares. The nominal (gains of 1 everywhere) measurement with DRMI locked (arms off resonance) is red circles. I don't think it makes sense to me why the crossover is so very different right now. I tried changing H1:SUS-BS_M3_DRIVEALIGN_L2L_GAIN as well as H1:SUS-BS_M2_DRIVEALIGN_L2L_GAIN, but never could get the crossover to look like anything sensible.
So, on the one hand, we still don't know why the DRMI OLGs are so weird, but on the other hand we can stay locked with DRMI for ~infinity minutes, as long as we touch up the alignment every 20 minutes or so.
I'm leaving the IFO requested to DOWN, so that when the DRMI finally drifts too much, it won't try to relock until a person is here to watch it.