PSL Status Report - Weekly FAMIS

PSL Status Report - Weekly FAMIS 64006

Laser Status:
    NPRO output power is 1.86W
    AMP1 output power is 70.67W
    AMP2 output power is 139.5W
    NPRO watchdog is GREEN
    AMP1 watchdog is GREEN
    AMP2 watchdog is GREEN
    PDWD watchdog is GREEN

PMC:
    It has been locked 14 days, 3 hr 2 minutes
    Reflected power = 28.44W
    Transmitted power = 104.6W
    PowerSum = 133.0W

FSS:
    It has been locked for 0 days 0 hr and 18 min
    TPD[V] = 0.4517V

ISS:
    The diffracted power is around 4.4%
    Last saturation event was 0 days 4 hours and 22 minutes ago


Possible Issues:
    PMC reflected power is high