Displaying report 1-1 of 1.
Reports until 11:03, Wednesday 16 September 2026
H1 SPI
jennifer.wright@LIGO.ORG - posted 11:03, Wednesday 16 September 2026 (91934)
Ground broken between chamber and rack for QPD

Jennie W, Fil C, Marc P,

 

To hopefully fix the intermittent noise on the SPI optical lever QPDs (see alog #91813), Marc and I pulled the ground pin (13) at the input to TIA chassis variant 2 in SUS-R3 rack and variant 1 in SUS-R2 rack, respectively. When the RCG upgrade is over I will run some dark noise measurements to check this noise is gone.

Displaying report 1-1 of 1.