Summary

We measured JAC's LSC in-loop error signal (JAC-L_SERVO_IN1) across the 2–62 W power sweep, calibrated each dataset from its own 30 Hz line, and built a residual length-noise budget (in-loop residual, sensor floor, shot floor). IMC locking reduces the equivalent laser-frequency noise by ~1.9× over 7.5–76.7 Hz (peak ~2.6× near 12 Hz); above ~30 Hz the residual is sensing-floor-limited. This budget is the input to the excess intensity- and frequency-noise coupling estimates.


Measurement


Analysis


Result


Next

Figure: free-run length noise with the sensor noise

Figure: residual noise budget — in-loop residual, sensor floor, shot floor, and their quadrature sum

Figure: equivalent laser-frequency noise, IMC on vs off,

Images attached to this report
Displaying report 1-1 of 1.