[Keita, Louis, Caroline, Elenna]
We are much closer to getting the 3f transition. We have confirmed we can swap PRCL from 1f to 3f while maintaining the same gain (no need for a factor as in 89567).
We have also confirmed what the 27I matrix value for SRCL needs to be to subtract PRCL from the error signal (2.7). We still need to test the 135I input matrix value by putting it into a blank matrix row, but we think it should be roughly -4.
We still have yet to to figure out what the MICH matrix value needs to be, but we think if we follow the same procedure as we did for SRCL, we can get there.
Regarding the DRMI ASC, we have not been successful in putting together a good MICH ASC signal. Unlike PRMI, the AS B RF45 signal is not going to work, but it looks like neither does the AS A RF45 signal. We might need to do a full sensing matrix and then use both sensors to construct a sensible signal. We could also check the AS 36 signals in case they are better.
I checked the air 3f phases and changed them slightly while running a PRM line to maximize PRM in I for both 27 and 135. Attached are screenshots of my measurements and SDF. I first started checking the phases while the SRCL mode hop offset was on, but then I turned it off. With the offset off, the phasing still looks fine.
We have also noticed the SRCL gain seems low by a factor of 2 (with nominal -33 gain from guardian). This is based on the idea that we want SRCL to have a UGF closer to 30 Hz. We don't think this is causing much of a problem right now, but it's something worth checking out and maybe guardianizing.
The MICH OLG still looks very strange, so there must be some cross coupling somewhere, but it's hard to tell what because the air 1f phases look ok, or at least Keita says "it's not wrong".
Unfortunately the day ended a little roughly, because suddenly we went from having very stable long DRMI locks to short locks that ring up quickly. Nothing on our end changed, so we don't understand what happened.
Procedure:
Additional locking notes from the morning:
I refined the BS and PRM alignment and got a good long lock. When 18MHz buildup of H1:LSC-POPAIR_B_RF18_I_ERR_DQ ~90 to 100 it was OK, it was a bit rough when this was ~80.
OTOH I'm observing something like mode-hopping behavior when 18MHz buildup is ~100. See attached video.
MICH gain was too high.
I noticed that something in LSC was (close to?) oscillation at maybe 13 or 14Hz and it was visible in MICH, PRCL and SRCL (when the IFO was not "mode hopping"). See reference traces in the attached.
I reduced MICH gain by a factor of 3 (H1:LSC-MICH1_GAIN=1) and the oscillation went away (current traces), and so did the "mode hopping"-like behavior. I'm going home now, but we must measure OLTF of LSC loops, paying attention to the coupling between DOFs.
It's not clear if MICH_GAIN=1 is good for acquisition so no change in the guardian yet. I'll leave it locked, and later will bring the guardian to DOWN from home.