After various ETMX transfer functions and offset tests, it looks like ETMX isn't rubbing anymore!
I did these tests this morning and wasn't able to get any rubbing. For everthing I did, L1 LL (and everyone else) moved as expected and no one got stuck anywhere. The offset tests that I did involved putting offsets in the L1 COILOUTF banks, M0 TEST banks, and R0 TEST banks and making sure L1 osems were all responding how we expected them to.
We noticed that L1 UL has been a little more jaggedly compared to the other L1 osems since we went to air, but the osem spectra looked good (comparing to its brethren) and putting a drive in M0 to move L1 around shows that UL is moving and behaving normally. We think it's probably just related to its current flag vs osem position as we put air in the chamber.
Transfer Functions
Settings:
- HEALTH_CHECK
- OPTICALIGN OFFSETS ON
- DAMP OFF
- ISI in ISI_DAMPED_HEPI_OFFLINE
M0
Data:
/ligo/svncommon/SusSVN/sus/trunk/QUAD/H1/ETMX/SAGM0/Data/2026-09-15_1540_H1SUSETMX_M0_WhiteNoise_{L,P,Y}_0p02to50Hz.xml
/ligo/svncommon/SusSVN/sus/trunk/QUAD/H1/ETMX/SAGM0/Data/2026-09-15_1540_H1SUSETMX_M0_WhiteNoise_{T,V,R}_0p03to50Hz.xml
r13152
Results:
/ligo/svncommon/SusSVN/sus/trunk/QUAD/H1/ETMX/SAGM0/Results/SAGM0/Results/2026-09-15_1540_H1SUSETMX_M0_ALL_TFs.pdf
r13153
R0
Data:
/ligo/svncommon/SusSVN/sus/trunk/QUAD/H1/ETMX/SAGR0/Data/2026-09-15_1615_H1SUSETMX_R0_WhiteNoise_{L,T,V,R,P,Y}_0p03to50Hz.xml
r13148
Results:
/ligo/svncommon/SusSVN/sus/trunk/QUAD/H1/ETMX/SAGR0/Results/2026-09-15_1615_H1SUSETMX_R0_ALL_TFs.pdf
r13150
Spectra:
L1
Data:
/ligo/svncommon/SusSVN/sus/trunk/QUAD/H1/ETMX/SAGL1/Data/2026-09-15_H1SUSETMX_L1_OSEMINF_spectra_invac_vs_inair.xml
r13149
Here's some comparisons of this in air ETMX measurement against the last good set of ETMX measurements that we had. They match well:
These can be found in /ligo/svncommon/SusSVN/sus/trunk/QUAD/Common/Data/
allquads_2026-09-15_ETMX_inair_RubbingCheck_ALL_TFs.pdf
allquads_2026-09-15_ETMX_inair_RubbingCheck_ALLM0_TFs.pdf
allquads_2026-09-15_ETMX_inair_RubbingCheck_ALLR0_TFs.pdf
allquads_2026-09-15_ETMX_inair_RubbingCheck_ALL_ZOOMED_TFs.pdf
allquads_2026-09-15_ETMX_inair_RubbingCheck_ALLM0_ZOOMED_TFs.pdf
allquads_2026-09-15_ETMX_inair_RubbingCheck_ALLR0_ZOOMED_TFs.pdf
r13154