Displaying report 1-1 of 1.
Reports until 12:15, Friday 25 September 2026
H1 SEI
jim.warner@LIGO.ORG - posted 12:15, Friday 25 September 2026 - last comment - 12:50, Friday 25 September 2026(92068)
CRS engaged on HAM3 now that the weather is cooperating

Because it's gotten quite windy outside, I've put the HAM3 CRS in-loop for RY. I don't expect this to cause any issues, but if the IMC starts showing a ~40 second oscillation, the CRS is a likely culprit. Doing a " caput H1:ISI-HAM3_BLND_RY_NEXT_CHAN 4 " in a terminal should revert HAM3 to nominal if there are any issues. Also since this is not a state set by any of the nominal guardians, any environment transion from SEI_ENV will also revert this.

Comments related to this report
jim.warner@LIGO.ORG - 12:50, Friday 25 September 2026 (92069)

Because people off site might be curious about what environmental reason made me want to turn the CRS on.

Images attached to this comment
Displaying report 1-1 of 1.