Displaying report 1-1 of 1.
Reports until 15:27, Friday 10 January 2014
H1 ISC
alexan.staley@LIGO.ORG - posted 15:27, Friday 10 January 2014 (9209)
HAM 1 beam diverter/PLC changes

While in HAM 1, we verified that the beam diverters were functional. Indeed they were; however, Corner Pop beam diverter (BDIV_B) was flipped in regards to open/close, so I have updated the PLC to reflect the proper positioning.