Reports until 17:09, Friday 10 January 2014
H1 SUS (CDS, IOO, ISC, SUS)
jeffrey.kissel@LIGO.ORG - posted 17:09, Friday 10 January 2014 (9213)
ECR E1300578 -- HTTS Screens Complete, Ready for Install at LLO
J. Kissel

After a few more tweaks of the individual HSSS screen, and creating the grouped RM and OM ALL screens, all HTTS modifications are complete and ready for deployment. Detailed instructions on how to install are listed below. Once LLO installs these changes (slated for next maintenance period), we can finally close out ECR E1300578. All necessary changes are committed to the userapps repo in various locations, again detailed below.

Installation Instructions
-------------------------
Capture alignment settings
(1) Make sure you either have alignment settings captured in a safe.snap, or at least handy for later.

SVN:
(2) svn update the sus corner of the userapps repository. (If you haven't accidentally updated already JAMIE, then) You should see a plethora of new files in the folders mentioned in LHO aLOG 9195. I've made further updates since that log, so be sure to update right when you're ready to install. Update the cds/h1/medm/ corner as well, so you get a feel for how the MEDM marco files need to be called from a sitemap.

Simulink:
(3) Create a new model ${ifo}sushtts.mdl (which you can probably copy from h1sushtts.mdl, to minimize labor). You'll need to 
- change the cdsParameter block to reflect the new ${ifo}, 
- change all of the IPC channel names,
(4) Create a new model ${ifo}susauxasc0.mdl (which again, you can copy from h1susaux.mdl, to minimize labor). You'll only to
- change the cdsParameter block to reflect the new ${ifo}
(5) Copy over changes (or simply overwrite) the ${ifo}susim.mdl model. You'll need to
- change the cdsParameter block to reflect the new ${ifo}, 
- change all of the IPC channel names,
(6) Compile all new/updated models.

Screen preparation:
(7) Set up your sitemap to call up either the individual HSSS screen,
${userapps}/sus/common/medm/hsss/SUS_CUST_HSSS_OVERVIEW.adl
or either of the groupings of HSSS,
${userapps}/sus/common/medm/hsss/
SUS_CUST_OM_OVERVIEW_ALL.adl
SUS_CUST_RM_OVERVIEW_ALL.adl
/opt/rtcds/userapps/release/sus/common/medm/haux/
SUS_CUST_HAUX_OVERVIEW_all.adl
(Note, eventually we'll move the HAUX overview into the hsss folder, and rename it properly capitalized)

Installation:
(8) Ask your sysadmin to prepare for the new installs by
- Removing h1asctt from 
- Adding h1sushtts and h1susauxasc0 to
all EDCU, master, IPC, .ini, etc files.
(9) Make-install and start the models.
(10) Restart the DAQ
--------------------

Once LLO has successfully installed everything and confirmed all necessary functionality, we can get rid of the 
${userapps}/sus/common/medm/haux, and 
${userapps}/sus/common/medm/htts 
folders, and get of any leftover HTTS stuff in the ASC folder, like the screens in 
${userapps}/asc/common/medm/asctt