TL,DR: We measure SRC gouy phase with no ring heaters, no ifo heating, no SR3 heating to be 18.5 +-0.4 deg. With SR3 at 4 W we measured 22.1 +-0.6 deg.
Louis and I measured the SRC gouy phase using the inertial gouy phase measurement technique previously performed by Stefan. Here is a list of reference alogs: 66211, 52639, 52658 52504
Before O4, with no ring heaters, IFO heating, etc, Stefan measured the SRC single pass gouy phase to be 19.5 +- 0.4 deg.
Measurement procedure:
Data analysis procedure:
Measurement systematics concerns:
Because of the low finesse of the SRC, distinctly identifying the 01 mode with peak finding next to the 00 mode can introduce bias. Sheila and I think that the best way to manage this bias is to fit the 00 peak and subtract it from the data, then peak find the 01. This is WIP.
In the meantime, I followed Stefan's method, where I leveraged the different response of each AS_C segment to HOMs, and found that seg1 is the most sensitive to the 00 mode and seg2 is the most sensitive to the 01 mode. I used seg1 to find the 00 mode, and those locations are used for the cubic spline fit. Then, I used the seg2 to find the 01 modes, and calculated the distance between these two modes for the gouy phase. I averaged the distance for all the fringes found in each measurement.
Results:
For cold IFO, no ring heaters, SR3 heater or other heating, the SRC single pass gouy phase is about 18.5 deg. This is one less degree of gouy phase than reported by Stefan in O4.
For cold IFO with SR3 heater set to 4 W (heated for 3 hours before measurement), the SRC single pass gouy phase is about 22.1-22.5 deg.
Plots are attached to this alog showing the fringes and the measured phase.
Some hypotheses:
These results indicate gouy phase has been reduced in the SRC. This could possibly be explained by the new beamsplitter having a different lens than the previous beamsplitter. The reduction in gouy phase could also explain why we are having such a significant mode hopping problem in DRMI 92046.
It appears that the SR3 heater can be used to increase the SRC gouy phase at least back to the O4 level, which may help our locking procedure.
I write that these are hypotheses because several other people are working on related studies that can help us understand if we are correct. Namely, we are using finesse to study if the new BS parameters can explain the loss in gouy phase, we are using what we know about the SR3 heater to see if the increase in gouy phase makes sense (and what heater setting we would need to correct the loss in phase), and we are also looking at data from an inertial PRC gouy phase measurement to see if we measure the same loss in gouy phase in the PRC. Keep an eye out for more information!
In the attached plot, the gray horizotnal lines show SRC gouy phase measurements with no ITM ring heaters on.
The vertical line is at the SR2- SR3 distance needed to explain the gouy phase of the cold measurement above. This is just a way to account for whatever unknown factors are setting the gouy phase, we are suspecting that the BS lensing may be different now than in O4 causing the decrease in the cold gouy phase, so this isn't actually the correct distance.
I adjusted the diopters per Watt value (4.7uD/W or 4.5uD/W is in 88413) to match the 4W SR3 heater measurement here. If we want to reproduce the cold gouy phase from O4, we would want to add 1W of SR3 heater. Elenna did turn that on this afternoon, in hope that this will help us avoid some mode hopping.