Updated the LHO PSL code to syrnchronzie with LLO
I updated the the LHO PSL code (FSS, ISS, PMC) to syrnchronzie with the LLO status, using all the common parts already in svn. This was slightly tricky, since there were some local changes at LHO that were never committed because the LLO files had changed. This also brings the PSL ODC code to the same status as LLO. Some more ODC threshold setup work will be required over the weekend to make sure the channel is green when it should be.

Files checked into svn: version 6832:
h1pslfss.mdl
h1psliss.mdl
h1pslpmc.mdl

I also re-implemented the local LHO changes to the common files, namely:
- $Id$ and $HeadURL$ tags for svn version keeping 
- Defining science channels by adding * in the DAQ block for the following channels:
   pslfss: FAST_MON_OUT, MIXER_OUT
   psliss: AOM_DRIVER_MON_OUT, PDA_OUT, PDB_OUT
   pslpmc: HV_MON_OUT, MIXER_OUT

Files checked into svn: version 6833:
pslfss.mdl
psliss.mdl
pslpmc.mdl

I guess LLO should syc those files to have the PSL run of the same library at both sites.


There is one more thing: psldbb.mdl I did not touch it today. LLO is up to date. LHO has some local mods (presumably from the MATLAB2012 move), BUT:
Both versions are so messed up with wiring that I do not dare touch it.