Displaying report 1-1 of 1.
Reports until 16:30, Friday 09 October 2026
H1 General
oli.patane@LIGO.ORG - posted 16:30, Friday 09 October 2026 (92268)
Ops DAY Shift End

TITLE: 10/09 Day Shift: 1430-2330 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Earthquake
INCOMING OPERATOR: Ibrahim
SHIFT SUMMARY: 

We are back to trying to relock after the big earthquake earlier today.

Locking notes:
Morning Initial Alignment
- Had to help XARM because it kept catching on wrong mode, but probably would've caught on its own eventually

Relocking
- Kept losing DRMI, mostly due to mode hopping - this was because the green arm references hadn't been sdf'd. After resetting the refs to what they were yesterday we were good
- Huge 7.6 earthquake come through and kept us down for multiple hours. It was in the BIG RED BUTTON zone, so I pressed the Big Red Button™.

LOG:                                                                                                                                                                                                                                                                                                                                 

Start Time System Name Location Lazer_Haz Task Time End
15:12 FAC Chris MX, MY n FAMIS tasks 16:00
16:11 ISC Sheila LVEA YES Setting up measurement 16:23
17:15 EE Marc CER YES Checking signal for Richard 17:22
22:24 TCS Sophie CHETALab y(local) Aligning laser ongoing
23:15 ISC Keita, Alex LVEA Y Changing OMC measurement settings 23:23
Displaying report 1-1 of 1.