locking today

Elenna, Sheila, Louis, Ryan Crouch, Tony

Summary- The IFO seems stable with ANALOG_CARM, and several ASC loops have been engaged.

 

Images attached to this report
Non-image files attached to this report
Comments related to this report
elenna.capote@LIGO.ORG - 09:45, Thursday 15 October 2026 (92314)

I think this got missed in the details, Louis and I tried to engage the common comp boost, which is a 40 Hz/4 kHz. We think it caused a lockloss, so we commented it out of the guardian for now.