(Alexa, Daniel, Sheila)
PLL Beatnote:
-
Beatnote height of -11.6dBm (or -24dBm before the preamplifier which has a gain of 12dB)
-
BBPD reads 5.2mW
-
Input 1 pol: NEG, Common Compensation: ON, Generic Filter: ON, Fast Option: ON, Fast Gain: -8dB, rest OFF ---- under this configuration we found the lock was unstable with the input 1 gain at 6dB
-
Turning Boost 1: ON, the lock was then unstable with the input 1 gain at 4dB
-
We decided the best stable configuration was with the input 1 gain set to 0dB (gives a factor of 2 gain margin)
PLL Open Loop Transfer Function:
-
Input 1 pol: NEG, Common Compensation: ON, Generic Filter: ON, Fast Option: ON, Fast Gain: -8dB, Input 1 Gain: 0db, rest OFF
-
EX_PLL_OpenLoopTFmag_BoostOff EX_PLL_OpenLoopTFphase_BoostOff (collected with SR785)
-
EX_PLL_OpenLoopTF_High_BoostOff/AAAA2.TXT (collected with RF spectrum analyzer for high freq)
-
UGF at 22kHz, phase margin of 50 deg
-
Input 1 pol: NEG, Common Compensation: ON, Generic Filter: ON, Fast Option: ON, Fast Gain: -8dB, Input 1 Gain: 0db, Boost 1: ON rest OFF
-
EX_PLL_OpenLoopTFphase_BoostOn (collected with SR785, need to recollect mag data)
-
EX_PLL_OpenLoopTF_High_BoostOn/AAAA3.TXT (collected with RF spectrum analyzer for high freq)
-
UGF at 26kHz, phase margin of 20 deg
PLL Noise Spectrum -- via IMON of PFD (S1000758)
-
PFD test report indicates the board has a noise of ~500nV/SqrtHz from IMON
-
Input 1 pol: NEG, Common Compensation: ON, Generic Filter: ON, Fast Option: ON, Fast Gain: -8dB, Input 1 Gain: 0db, rest OFF
-
EX_PLL_Noise_PFD_BoostOff (collected with SR785)
-
EX_PLL_Noise_PFD_High_BoostOff/AAAA4.TXT (collected with RF spectrum analyzer for high freq)
-
Input 1 pol: NEG, Common Compensation: ON, Generic Filter: ON, Fast Option: ON, Fast Gain: -8dB, Input 1 Gain: 0db, Boost 1: ON, rest OFF
-
EX_PLL_Noise_PFD_BoostOn (collected with SR785)
PLL Servo Board Transfer Function:
-
Input 1 pol: NEG, Common Compensation: ON, Generic Filter: ON, Fast Option: ON, Fast Gain: -8dB, Input 1 Gain: 0db, rest OFF
-
EX_PLL_ServoBoard_TFmag_BoostOff, EX_PLL_ServoBoard_TFphase_BoostOff (collected with SR785)
-
Input 1 pol: NEG, Common Compensation: ON, Generic Filter: ON, Fast Option: ON, Fast Gain: -8dB, Input 1 Gain: 0db, Boost 1: ON, rest OFF
-
EX_PLL_ServoBoard_TFmag_BoostOn, EX_PLL_ServoBoard_TFphase_BoostOn (collected with SR785)
-
Note: DC gain of -30dB nominal
Shot Noise of PLL BBPD:
-
Measured noise from laser to be -95dB at 100Hz BW
-
Noise of RF spectrum was -100dBm at 10Hz BW