Reports until 10:14, Friday 17 January 2014
H1 ISC
daniel.sigg@LIGO.ORG - posted 10:14, Friday 17 January 2014 (9357)
EX ALS REFL servo board

Due to the higher than expected cavity pole we are using the first boost stage (pole at 100 Hz and zero at 1 kHz) as part of the compensation. The second boost stage is too high in frequency. This morning we modified the second boost stage to be identical to the first one with a pole at 100 Hz and a zero at 1 kHz. This is serial number S1102630. In detail:

The removed parts are in a bag taped to the inside of the chassis.