richard.mccarthy@LIGO.ORG - posted 12:24, Friday 17 June 2011 (938)
ISI Test Stand
Testers had DAC problems yesterday and were unable to get outputs.  As noted by the SUS team a lot of time was spent looking into this as thought SUS and ISI were related.  They were not.  The AI chassis on the ISI test stand had a blown -15V regulator thus not powering the boards and signals could not pass through.  We fixed the Inductor in question and I was able to see outputs once again.