I tried the PZT dither today: - The green arm transmitted signal is now available in the ASC system (ADC card 3, channel 24-27 [25-28], are connected to output 1-4 form the the ALS PD concentrator 3) - I used the demodulated green arm transmitted signal for all the loops I tried today. - Dithering PZT2 provided a nice error signal for TMS pointing. - Dithering PZT1 gave an error signal that I couldn't zero out - not sure why yet. (TMS position offset?) - Dithering ITM at 1.7 Hz provided a good loop for aligning ITMY. - The loop did a good job aligning the cavity, but mode-hopping was still hampering the effort. Still to do: - Try higher frequency ITM dither (lower stage drive?) - Investigate PZT1 dither error signal offset - Try Green QPD pointing offset? - Do yaw loops.