Displaying report 1-1 of 1.
Reports until 11:59, Thursday 23 January 2014
H1 ISC (ISC)
corey.gray@LIGO.ORG - posted 11:59, Thursday 23 January 2014 (9491)
EY TMS Cable Notes

With the recent cabling work at EY, wanted to record notes of where we're at and inventory. 

Problem Cable

Performed elec short tests on in-vac cables, and found an issue with one:  D1000223 S1104078's pin #1 & #23 (may be able to use a D1000225 in its place)

Screws On Cable Feedthru Connectors Confirmed To Be "Screwed In" All The Way

It has been brought up that a possible source of grounding are the sets of screws on the connector which attaches to a Chamber feedthru.  Through handling sometimes these screws can unscrew, and even a little bit will have them protrude out and short to the Chamber.  I went ahead and applied a torque to all of these connectors for TMS cables.  (attaching a photo of these screws on our 25-pin connetors....with head on shot and profile)

Missing Screws For Attaching To Feedthru

In the table below there is a note of cables which are missing screws which attach cables to the in-vac side of the feed-thru.

Cables Screwed Together & Unfortunate Cable Bracket Attachement

Since we've tested all these cables, I went ahead and screwed all cables together (noting we'll have to unscrew the bad D1000223 at some point).  In our Cable Layout drawing (D1200111), the D1000921 cables for the Picomotor & Beam Diverter are said to be OK with connectors "with or w/o metal ears".  If you do not have metal ears, you sort of make life hard for you in that if you have to look at a cable you can't simply unscrew it from the cable bracket.  You remove access to the Cable set screw, so you have to remove both cables and then disconnect cables---which is a pain.

ICS & Inventory Of Cables

I have made an Assembly Load for the TMS EY Cables (ASSY-D1200111).

In-Air Cable
 
Chamber
feed-thru
Seismically-Responsible Cables Cable Bracket In-Vac Cable Cable Bracket
on TMS
In-Vac Component
: Not sure of name : E6-7C1 D1000225 s/n S1104782
*no feedthru screws?
CB-5 , 1st Floor D1000234 s/n96-911 no CB OSEMS:  Face1, Face2, Face3, Left
: Not sure of name : E6-7C2 D1000225 s/n S1104778
*no feedthru screws?
CB-5 , 2nd Floor D1000234 s/n96-901 no CB OSEMS:  Right, Side, ---, ---
: Not sure of name : F2-2C1 D1000924 s/n S1104106
*no feedthru screws?
CB2 , 1st Floor (was 3rd Floor of BSC6 CB) D1000568 s/nS1104468 CB-primary, 1st floor Green QPD (D1000231 s/n C2Q001 aka S1400085)
: Not sure of name : F2-1C2 D1000924 s/n S1104469 CB2 , 2nd Floor (was 2nd Floor of BSC6 CB) D1000568 s/nS1104109 CB-primary, 2nd floor Red QPD (D1000231 s/n C4Q001 aka D1400087)
: Not sure of name : F2-1C1 D1000223 s/n S1104077
*no feedthru screws?
CB1 , 1st Floor (was 1st Floor of BSC6 CB) D1000921 s/nS1104116 CB-entry, 2nd floor Picomotors (D1000238 s/n1104586)
: Not sure of name : F2-2C2

D1000223 s/n S1104078--possible short w/ pin 1 & 23

CB1 , 2nd Floor (was 4th Floor of BSC6 CB) D1000921 s/nS1104114 CB-entry, 1st floor Beam Diverter (D1000237 s/nS1104289)
Images attached to this report