(Alexa, Sheila)
We wanted to compare our senstitivty to angular motion between HIFOX and Y. I used Seigman (Lasers, Chap 19) equation for the beam displacement from the optical axis as a function of mirror displacements. In my calculation, I used the following values
-
L = cavity length = 3994.472 (alog 9402)
-
IMTX_ROC = 1939.52m ETMX_ROC = 2241.54m
-
TTMY_ROC = 2307m ETMY_ROC = 2313m (from LIGO-T1300158)
-
Assumed all mirror motion was .1urad.
I found the ratio of HIFO X to HIFOY for...
-
motion of ETM resulting in displacement on ETM = 2.86
-
motion of ETM resulting in displacement on ITM = 2.29
-
motion of ITM resulting in displacement on ETM =1.97
-
motion of ITM resulting in displacement on ITM = 2.46