Another PtoP measurement on the M2 stage of PRM was launched at around 1:15 AM. It is running on opsws8 (which is Kissel's favorite workstation).
The diag file is in the official place:
/ligo/svncommon/SusSVN/sus/trunk/HSTS/H1/PRM/Common/Data/2014-01-25-H1SUSPRM_M2_PtoP_SweptSince_0p2to5Hz.xml
PRM:
We had to restart the measurement around 2pm because of a template bug.
But we put the Y2Y measurement in the automatic queue, so it should start as soon as the P2P measurements finishes.
BS:
- the BS P2P finished, the Y2Y is now in progress
PR2: the anti-dewhitening on the PR2 is different from the PRM, so the templates have to be adapted smartly. We haven't done any PR2 measurements yet.
ETM and ITM:
We started L2 Y2Y measurements for those two suspensions. THey are in diaggui's and need to be safed in the morning.