Reports until 14:34, Monday 27 January 2014
H1 SUS
mark.barton@LIGO.ORG - posted 14:34, Monday 27 January 2014 - last comment - 10:47, Friday 07 February 2014(9575)
ETMy OL values

Betsy swapped all the BOSEMs and AOSEMs on ETMy and left them retracted for open light measurements. The resulting values with gains and offsets are:

prettyOSEMgains('H1','ETMY')

M0F1 30218 0.993 -15109
M0F2 29922 1.003 -14961
M0F3 29480 1.018 -14740
M0LF 31134 0.964 -15567
M0RT 30792 0.974 -15396
M0SD 31110 0.964 -15555
R0F1 31059 0.966 -15529
R0F2 30058 0.998 -15029
R0F3 29953 1.002 -14977
R0LF 30794 0.974 -15397
R0RT 31050 0.966 -15525
R0SD 30282 0.991 -15141
L1UL 29222 1.027 -14611
L1LL 30117 0.996 -15059
L1UR 25735 1.166 -12868
L1LR 22721 1.320 -11361
L2UL 21334 1.406 -10667
L2LL 24582 1.220 -12291
L2UR 21223 1.414 -10612
L2LR 20325 1.476 -10163

I entered the gains, checked that all the outputs were right (should be 15000*0.023333=350) and redid the safe.snap.

 

prettyOSEMgains('H1','ETMY')
 
data =
 
   1.0e+04 *
 
    3.0218
    2.9922
    2.9480
    3.1134
    3.0792
    3.1111
    3.1059
    3.0058
    2.9953
    3.0793
    3.1050
    3.0282
    2.9221
    3.0117
    2.5735
    2.2721
    2.1334
    2.4582
    2.1223
    2.0325
 
 
ans =
 
M0F1 30218 0.993 -15109
M0F2 29922 1.003 -14961
M0F3 29480 1.018 -14740
M0LF 31134 0.964 -15567
M0RT 30792 0.974 -15396
M0SD 31110 0.964 -15555
R0F1 31059 0.966 -15529
R0F2 30058 0.998 -15029
R0F3 29953 1.002 -14977
R0LF 30794 0.974 -15397
R0RT 31050 0.966 -15525
R0SD 30282 0.991 -15141
L1UL 29222 1.027 -14611
L1LL 30117 0.996 -15059
L1UR 25735 1.166 -12868
L1LR 22721 1.320 -11361
L2UL 21334 1.406 -10667
L2LL 24582 1.220 -12291
L2UR 21223 1.414 -10612
L2LR 20325 1.476 -10163
prettyOSEMgains('H1','ETMY')
 
data =
 
   1.0e+04 *
 
    3.0218
    2.9922
    2.9480
    3.1134
    3.0792
    3.1111
    3.1059
    3.0058
    2.9953
    3.0793
    3.1050
    3.0282
    2.9221
    3.0117
    2.5735
    2.2721
    2.1334
    2.4582
    2.1223
    2.0325
 
 
ans =
 
M0F1 30218 0.993 -15109
M0F2 29922 1.003 -14961
M0F3 29480 1.018 -14740
M0LF 31134 0.964 -15567
M0RT 30792 0.974 -15396
M0SD 31110 0.964 -15555
R0F1 31059 0.966 -15529
R0F2 30058 0.998 -15029
R0F3 29953 1.002 -14977
R0LF 30794 0.974 -15397
R0RT 31050 0.966 -15525
R0SD 30282 0.991 -15141
L1UL 29222 1.027 -14611
L1LL 30117 0.996 -15059
L1UR 25735 1.166 -12868
L1LR 22721 1.320 -11361
L2UL 21334 1.406 -10667
L2LL 24582 1.220 -12291
L2UR 21223 1.414 -10612
L2LR 20325 1.476 -10163
Comments related to this report
travis.sadecki@LIGO.ORG - 10:47, Friday 07 February 2014 (9910)

Corresponding serial numbers as follows:


M0F1 094
M0F2 588
M0F3 266
M0LF 058
M0RT 041
M0SD 095
R0F1 050
R0F2 186
R0F3 422
R0LF 180
R0RT 056
R0SD 083
L1UL 477
L1LL 493
L1UR 485
L1LR 022
L2UL 473
L2LL 428
L2UR 332
L2LR 321