PR2 M3 pitch drivealign work - not perfect, but probably good enough
Kiwamu, Stefan,

We did the PRM M3 pitch L2P decoupling tonight. We followed that same strategy as for the PR2 (alog 9584):
 - We paid the  most attention to the highest peaks in the L2P transfer function.
 - We fitted L2P and P2P independently to get good initial values for a fit of the ratio.
 - We had a harder time with the L2P (compared to the PR2) - in particular I couldn't get the phase at 1Hz right.
 - The result is only 

Plot 1:  transfer functions:
 - blue:   measured L2P TF
 - green:  measured P2P TF
 - red:    L2P/P2P (from measured data)
 - black:  fit (note that we paid more attention to the frequencies between 0.5Hz and 1Hz, because they matter most (see L2P)
 - Purple: fitted filter times measured P2P.

Plot 2: decoupling at 0.75Hz about a factor of 6 better.
Plot 3: decoupling at 0.95Hz about a factor of 4 better.