Displaying report 1-1 of 1.
Reports until 08:44, Thursday 30 January 2014
H1 PSL (PSL)
patrick.thomas@LIGO.ORG - posted 08:44, Thursday 30 January 2014 (9648)
PSL check
Output power is 29.3 W (should be around 30 W)
FRONTEND WATCH is green
HPO WATCH is red
SysStat is good

PMC has been locked 1 day, 16 hr (should be days/weeks)
Reflected power is 10.9% of transmitted power (should be <= 10%)

FSS has been locked for 10 min (should be days/weeks)
Resonant threshold is .5V (should be .9V)

ISS diffracted power is around 8.8% (should be 10%)
Last saturation event was 16 min ago (should be days/weeks)
Displaying report 1-1 of 1.