Reports until 18:16, Thursday 30 January 2014
H1 CDS
david.barker@LIGO.ORG - posted 18:16, Thursday 30 January 2014 - last comment - 23:51, Thursday 30 January 2014(9684)
ALS top named part added to ASC model, channels not named correctly by RCG
Daniel noticed that following his inclusion of an ALS top_named part in the h1asc model this morning, the channels were being incorrectly named at H1:ASC-ALS_ instead of the expected H1:ALS-. Jim, Cyrus and myself spent some time diagnosing the problem and found that the problem is raised if the second part comes before the main part (ASC) in alphabetical order. In other words ALS was not correctly identified as a top_named part but ATT was. It appears the problem may be in the post_built python script where the "top_names" block property is parsed. We did some diagnostics with the h1asc model, so there may be some strange MEDM screens lying around. We never did a "make install" so the INI file was not changed since this morning.
The investigation continues.
Comments related to this report
sheila.dwyer@LIGO.ORG - 23:51, Thursday 30 January 2014 (9697)

I did two make installs this morning, apologies if this caused probems.