(Alexa, Daniel, Keita)
After changing the RF frequency to 24.389319 MHz and adjusting the delay line phase to 257 steps, we took open loop transfer functions of the PDH loop.
PLL Board Settings:
PDH Board Settings (Nominal):
EX_PDH_OpenLoopTF_phase/mag_Nom.txt corresponds to the data collected with the above nominal settings.
EX_PDH_OpenLoopTF_phase/mah_Boost2On.txt corresponds to the data collected wiith the above settings with the addition of Boost 2 ON
EX_PDH_OpenLoopTF_phase/mag_6dBFast.txt corresponds to the data collected with the same as the nominal settings with the addition of 6dB gain in the fast path