Reports until 10:12, Friday 31 January 2014
H1 ISC
alexan.staley@LIGO.ORG - posted 10:12, Friday 31 January 2014 (9708)
EX PDH Open Loop TF

(Alexa, Daniel, Keita)

After changing the RF frequency to 24.389319 MHz and adjusting the delay line phase to 257 steps, we took open loop transfer functions of the PDH loop.

PLL Board Settings:

PDH Board Settings (Nominal):

 

EX_PDH_OpenLoopTF_phase/mag_Nom.txt corresponds to the data collected with the above nominal settings.

EX_PDH_OpenLoopTF_phase/mah_Boost2On.txt corresponds to the data collected wiith the above settings with the addition of Boost 2 ON

EX_PDH_OpenLoopTF_phase/mag_6dBFast.txt corresponds to the data collected with the same as the nominal settings with the addition of 6dB gain in the fast path

Non-image files attached to this report