Reports until 21:11, Sunday 02 February 2014
H1 ISC
stefan.ballmer@LIGO.ORG - posted 21:11, Sunday 02 February 2014 - last comment - 21:15, Sunday 09 February 2014(9741)
PRMI locking
The MC2 roll mode notch (FM6 in ISCINF) was left off overnight, resulting in a rung up 28Hz peak in MC_L, which was producing a huge signal in PRCL. Once on the peak slowly disapeard.

PRMI locking is now quite reliable. However we still have relatively big power fluctuations.

I recorded today's settings in a setup script: sballmer/tempfixes/setPRMI
Really, this should be fed to a guardian.

Images attached to this report
Comments related to this report
stefan.ballmer@LIGO.ORG - 21:13, Sunday 02 February 2014 (9742)
I left the PRMI locked tonight.
stefan.ballmer@LIGO.ORG - 10:06, Monday 03 February 2014 (9747)
PRMI stayed locked for 9h with only 1 lock loss in the middle.

1st lock: 2014/02/03  05:03:00  to  08:39:00 (duration 3h36min)
2nd lock: 2014/02/03  08:41:00  to  14:31:00 (duration 5h50min)

All times UTC.
Images attached to this comment
shivaraj.kandhasamy@LIGO.ORG - 21:15, Sunday 09 February 2014 (9939)

The coherence analysis using STAMP-PEM revealed strong correlation (0.5 Hz) between H1_SUS-ITMX_L3_OPLEV (YAW and PIT) and H1:ALS-X_ARM_IN1_DQ. The coherence plots produced by Patrick can be accessed from here. Josh did follow up studies confirming the presence of 0.5 Hz strucutre in ITMX oplev signals and also saw strong correlation between ITMX oplev and POPAIR signals. The coherence plots Josh made can be accessed from here.