This morning I finished rolling out available guardian updates for suspension (following alog 9733)
guardctrl create SUS_MC1
guardctrl start SUS_MC1
Suspension | Currently saved offset (Pitch/Yaw) | Last time saved / Offset (Pitch/Yaw) | |
MC1 | 883.3 / -1945.7 | Jan 31st :17:10 | same as current |
MC2 | 470.4 / 257.2 | Jan 31st 17:20 | same as current |
MC3 | -460.4 / 2119 | Jan 31st 17:10 | same as current |
PRM | -730 / -459 | Jan 31st 17:20 | same as current |
PR2 | 462.8 / -314.5 | Feb 2nd 19:14 | same as current |
PR3 | -240.32 / -252.3 | Jan 31st 16:35 | same as current |
ITMX | 64.3 / -56.8 | Feb 2nd 19:19 | same as current |
ITMY | 46.8 / -140 | Feb 2nd 19:19 | same as current |
ETMX | 256.7 / 79.8 | Jan 17th 18:54 | 253.5 / 79.7 |
TMSX | 267.9 / -242.7 | Jan 17th 20:33 | 244.2 / -239 |
BS | 44 / -251 | Jan 31st 17:21 | same as current |
changed the command of the guardian button from /ligo/apps/ubuntu12/guardian/bin/guardmedm to -> guardmedm
- The sitemap needs to be started from a terminal in order to either save the offsets, or open a guardian medm screen.
- Managing the way the offsets are saved. For now there is 4 txt files per suspension under /opt/rtcds/userapps/release/sus/h1/burtfiles.
one .req file defining the two offset epics channels, one snap file for the aligned value, one snap file for the misaligned value, one file saving all the aligned offsets with the date it was changed.