ETMX ISI tripped, going to end X

I found the BSC 9 ISI tripped this morning, Stage 1 Watchdog trip, actuator limit was the first trigger. 

I also noticed that yesterday morning the ETM reaction mass was misalinged, and -600 coutns offset was added in ETMX M0 Locking filters.  I've turned both of these off, but still don't see a reflected beam, so I'm heading to the end station to have a look.

Comments related to this report
sheila.dwyer@LIGO.ORG - 07:17, Tuesday 04 February 2014 (9780)

We are back from the end station, the TMS offsets were also off.  Also, the ITMX HEPI and ISI were tripped, with a CPS saturation alarm.