Reports until 09:08, Wednesday 05 February 2014
H1 AOS
jason.oberling@LIGO.ORG - posted 09:08, Wednesday 05 February 2014 - last comment - 10:21, Wednesday 05 February 2014(9833)
ETMy Cartridge Alignment
IAS: J. Oberling
SUS: B. Weaver, T. Sadecki
 
Finished the ETMy cartridge alignment yesterday.  The position & angular errors are as follows (all yaw reported as viewing the relevant optic from the top down):

Also measured & aligned the ERMy (Note: the ERMy is aligned parallel to the AR surface of the ETMy) and measured the gap between the ETMy and ERMy.

Comments related to this report
betsy.weaver@LIGO.ORG - 10:21, Wednesday 05 February 2014 (9837)

Note - we discovered yesterday that the Kentek gap detector was highly dependent on how level it's mounting was.  So, the measurement is only good to about +/-0.25mm.