Looked at photo diode forward voltage for ETMY ACB per LIGO-T1100637.
PD forward voltage(≈ 0.5V)

Pin 13 & 12 
PD forward voltage: 0.428V

Pin 10 & 9 
PD forward voltage: 0.421V

Pin 7 & 6
PD forward voltage: 0.428V

Pin 4 & 3
PD forward voltage: 0.421V


Filiberto Clara & Mitchell