ETMY TF still looking good

Results of last set of ETMY transfer function after finishing the alignment (see this alog for alignment numbers) are attached below, and look similar to what was taken monday night. TMS team can start (and probably already did) work on the installation. SUS will go in the next days check for lower masses flag/osem centering as well as top mass verticals. 

Attached files :

H1 ETMY fiber after finishing alignment (in black) compared to first alignment (in orange) compared to LLO ETMX fiber in chamber. Main chain (1st pdf) and reaction chain (2nd pdf)

To notice :

- First pitch mode of the main chain fiber quads are shifted down (0.52Hz) compared to the model (0.562Hz). Cf p5 of first attachment.