Reports until 13:45, Friday 07 February 2014
H1 SUS
filiberto.clara@LIGO.ORG - posted 13:45, Friday 07 February 2014 (9916)
EX - PUM Monitor Readbacks Channels
Arnaud reported PUM monitor readback channels not changing states. Looked at binary commands coming into chassis and could see inputs changing states. The relays could also be heard changing states. Outputs did not change. 
Had similiar issue at corner station https://alog.ligo-wa.caltech.edu/aLOG/index.php?callRep=3153 

Replaced R111 from 10K to 100K on all channels. All monitors are responding as expected. 
D1100303 Serial Number S1000343.

Filiberto Clara