PRMI guardian beta version released

I have created a new guardian which watches the PRMI locking. Once green team finishes their locking activity, we will test this out with the real interferometer.

It is currently in

/opt/rtcds/userapps/release/lsc/common/guardian/LSC_PRMIsb.py

This guardian script looks into an up script which is in

/opt/rtcds/userapps/release/lsc/h1/scripts/autolock/prmi/sideband/prmi_sb_up.py

If you want to refresh the PRMI locking settings, you can always command this up state and it sets up the LSC settings and PRM/PR2/BS settings upon a request.


 