Doug, Rick, Craig Friday we finished the P-Cal periscope installation and alignment Final results after periscope lock down with the steering mirrors added: Pitch: -6.0 micro radians (desired +/- 200 micro radians) Yaw: 22 micro radians (desired +/- 200 micro radians) Longitudinal: EDM reading 1,575 mm (desired 1,574.56 mm) L= 5,629.8 mm (HR to monument) - 4055.237 mm Periscope to HR face)= 1,574.56 tolerance +/- 3.0 mm Latitude: within the 0.5mm width of the vertical target cross hair. (tolerance +/- 2.0 mm) Vertical: within the 0.5mm width of the horizontal target cross hair. (tolerance +/- 2.0 mm) Roll: within the 0.5mm width of the vertical horizontal target cross hair. (tolerance +/- 2.0 mm) All measurement made in relationship to the beam line perpendicular to the HR face (00. 02'.12" pitched down (639 micro rads. total station pointing up -89deg 57'48" P-cal doc E1300477; IAS alignment doc E1200953 ( both are being update to the as built versions with corrects)