Reports until 11:26, Monday 10 February 2014
alexan.staley@LIGO.ORG -
posted 11:26, Monday 10 February 2014 (9946)
PLL Servo Board Settings
-
Input 1 pol: NEG
-
Input 1 gain: 0dB
-
Input 1 enable: ON
-
Common Comp: ON
-
Generic Filter: ON
-
Fast Option: ON
-
Fast gain: -8dB
-
Fast pol: NEG
PDG Servo Board Settings
-
Input 1 pol: NEG
-
Input 1 gain: -1dB
-
Common Comp: ON
-
Boost 1: ON
-
Fast Pol: NEG
-
Fast gain: 0dB
-
PDH Error signal amplitude spectrum: EX_PDH_NoiseSpectrum.txt
-
PDH "shot" noise: EX_PDH_ShotNoiseSpectrum.txt
-
PDH open loop TF: EX_PDH_TFOpenLoop_mag/phase.txt