H1 SUS
arnaud.pele@LIGO.ORG - posted 17:16, Tuesday 11 February 2014 (9987)
SUS monitor channels added to frame/science frame #WP 4179

Today I finished up modifying the SUS monitor models as it has been deployed at LLO in december (alog 9964 and alog 10010), under ECR 1300261 in order to add the voltage and noise monitors in the frame + science frame for each individual osem. The following models were modified, recompiled, and commited to the svn :

h1susb123 (bs, itmx, itmy) rev 7070
h1susauxh2 (mc1, mc3, prm, pr3, im1, im2, im3, im4) rev 7087
h1susauxh34 (mc2, pr2, sr2) rev 7072
h1susauxh56 (srm, omc)  rev 7074
h1susauxex (etmx, tmsx)  rev 7083
h1susauxey (etmy, tmsy) rev 7085

Details of modifications are specified below :

For the quads :

M0/R0 Noisemon was changed from 1024 to 512Hz
M0/R0 Voltmon was changed from 1024Hz to 256Hz
L1/L2 Noisemon were created at a rate of 1024Hz
L1/L2 Voltmon were created at a rate of 256Hz

For the triple suspensions :

M1 M2 M3 Voltmon added at 256Hz
M1 Noisemon added at 512Hz, M2 at 1024Hz and M3 at 2048Hz

For the IMs and OMCs

M1 Voltmon added at 256Hz
M1 Noisemon added at 512Hz

For the TMS :

M1 Voltmon added at 256Hz
M1 Noisemon added at 256Hz