TITLE: 03/15 Eve Shift: 23:00-07:00 UTC (16:00-00:00 PST), all times posted in UTC
STATE of H1: Observing at 114Mpc
INCOMING OPERATOR: Corey
SHIFT SUMMARY: Locked in Observe, range trending downward, no obvious reason
LOG:
After Rhaul loaded his change to the guardian code on Friday 55575, I expected that the guardian would no longer be setting gains to 0. It looks like we have lost lock and relocked since the guardian change was loaded so it should have gone into place. Did you find the gain set to 0?
Here Guardian is setting it to max gain which is 0 for ITMY 12 (nominal is 1200).
H1 locked in Observe, winds are below 20mph, and temperatures are below freezing, around 29F, -1.2C.
TITLE: 03/14 Eve Shift: 23:00-07:00 UTC (16:00-00:00 PST), all times posted in UTC
STATE of H1: Observing at 117Mpc
OUTGOING OPERATOR: Camilla
CURRENT ENVIRONMENT:
SEI_CONF state: WINDY
Wind: 22mph Gusts, 20mph 5min avg
Primary useism: 0.06 μm/s
Secondary useism: 0.32 μm/s
QUICK SUMMARY: locked in Observe
TITLE: 03/14 Day Shift: 15:00-23:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Observing at 116Mpc
INCOMING OPERATOR: Cheryl
SHIFT SUMMARY: Locked 10h45. Quiet day with steady 20+mph wind.
LOG: 20:27 UTC Trolley rolled down corridor (noting incase it caused noise in IFO)
Observing for 6h45. Wind is still ~20mph and microseism has started to increase over the last few hours.
TITLE: 03/14 Eve Shift: 23:00-07:00 UTC (16:00-00:00 PST), all times posted in UTC
STATE of H1: Observing at 113Mpc
INCOMING OPERATOR: Corey
SHIFT SUMMARY: H1 currently locked in Observe, out once to relock SQZ
LOG:
Attached are 3 plots showing the change in voltage on the PZT, then SQZ rining up, and then relocking. The first relock was unchanged, second was a tiny bit better, and third caught and SQZ rang down. H1 out of Observe at 05:20:57UTC, and back in Observe at 05:33:45UTC.
Shifter: Adrian Helmling-Cornell
Fellow: Phil Jones
DQ Shift Summary:
Locked in Observe, winds have come down to less than 10mph, range is 117Mpc.
TITLE: 03/13 Eve Shift: 23:00-07:00 UTC (16:00-00:00 PST), all times posted in UTC
STATE of H1: Observing at 119Mpc
OUTGOING OPERATOR: TJ
CURRENT ENVIRONMENT:
SEI_CONF state: WINDY
Wind: 13mph Gusts, 10mph 5min avg
Primary useism: 0.04 μm/s
Secondary useism: 0.18 μm/s
QUICK SUMMARY: locked in Observe
TITLE: 03/13 Day Shift: 15:00-23:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Observing at 116Mpc
INCOMING OPERATOR: Cheryl
SHIFT SUMMARY: Two lock losses this shift for unknown reasons. Both relocks were a non-issue.
LOG:
Unknown reason for lock loss at this time.
Observing 2234 UTC.
40min autonomous relock from lock loss to observing. Maybe an O3 LHO record? Well done everyone!!
Had to move both ETMY and TMSY a decent way to get light onto the camera (20 counts on the slider for ETMX Pit and 15 for TMSY Pit).
Had dragged TMSY too far away from it's normal position so that we were not getting enough light on the QPD's and had ALS_Y in fault with message "PZT trig servo not on". I think this is a different problem to the one disrupted by TJ in alog alog 54526 but it may be related.
Keita helped me to get light back on the QPDs:
From sitemap>ALS> End Y overview > QPD_A (FE) and QPD_B (FE), the NSUM should be ~1 for green arms locking, was closer to 0.05. after deciding that the suspensions had bee moved too much, we the QPD NSUMs and the alignment sliders and reverted them to their values at the time of last green arms locking, then did the same for the BIAS on the PZT1 and PZT2 PIT and YAW filters. NSUMS then came up to 1. Rs-adjusted the PZT filter bias numbers to be closer to their outputs and then continued locking.
We have just lost PRMI lock (not total lock) 3 times after I noticed that the FIND_IR TR_Y trace was way higher than it should be attached photo (20 rather than 1). Something strange must have happened so I will try and initial alignment.
DRMI locked straight away after a smooth initial alignment. Unsure what went on before!
At the start of this locking acquisition, there was no light on ALS-Y_QPD_B (NSUM ~ 0.05). ALSY PZT1 and PZT2 were then not adjusted. It can be seen from the top 2 plots of the attached image that they were being significantly adjusted at the start of each green arms locking to maximize QPD light. Keita helped me move the PZT1 and PZT2 values closer to the values which maximized NSUM in the past so in future they should not be so far away.
It's still not clear why there was no light on QPD_B to start with. The values of PZT1 and PZT2 do drift over time to give the maximum light on the QPDs so it's possible that to was just out of range. Maybe these biases should be checked and adjusted more regularly. Tagging ISC