jeffrey.bartlett@LIGO.ORG - posted 09:08, Tuesday 18 February 2020 (55152)
Bi-Monthly HEPI Pump Checks (FAMIS #13497)

All HEPI pumps are running well. Noted no new or increased leaks.
CS - Level 6 5/16", No change from last check.
EX - Level 7 13/16, No change from last check.
EY - Level 8 14/16, No change from last check.

Closing FAMIS #13497

 

H1 PEM
jeffrey.bartlett@LIGO.ORG - posted 09:02, Tuesday 18 February 2020 (55151)
Bi-Monthly Dust Monitor Vacuum Pump Checks (FAMIS #13007)
All three dust monitor vacuum pump are running well.
Made small tweaks to vacuum pressure at End-X and End-Y.
The CS pressures are good. All temperatures are within spec.
Noted no carbon dust on any of the three mufflers.
 
Closing FAMIS #13007
H1 AOS (GRD)
jameson.rollins@LIGO.ORG - posted 08:37, Tuesday 18 February 2020 (55150)
Completed guardian log rotation/expiration change (WP 8536, ECR 1900337)

The h1guardian1 journald config was changed to hold onto logs for only the last 2 months, and to increase individual log file size from 128M to 512M.  This should significantly speed up guardian log access.  The change mirros what was done at LLO in November (LLO alog 50166).

etckeeper was also installed on h1guardian1 to track config changes in /etc, and the above change was committed:

root@h1guardian1:/etc# git show
commit 2c2a61e46417dfef73133259faa0c1869cefc6ee
Author: root
Date:   Tue Feb 18 08:25:10 2020 -0800
    journald config change for ECR1900337
diff --git a/.etckeeper b/.etckeeper
index 38e0b55..dfb8f96 100755
--- a/.etckeeper
+++ b/.etckeeper
@@ -44,7 +44,7 @@ mkdir -p './systemd/user'
 mkdir -p './udev/hwdb.d'
 maybe chmod 0755 '.'
 maybe chmod 0700 '.etckeeper'
-maybe chmod 0644 '.gitignore'
+maybe chmod 0600 '.gitignore'
 maybe chmod 0755 'NetworkManager'
 maybe chmod 0755 'NetworkManager/dispatcher.d'
 maybe chmod 0755 'NetworkManager/dispatcher.d/ntp'
diff --git a/systemd/journald.conf b/systemd/journald.conf
index 7536bc0..6976a9c 100644
--- a/systemd/journald.conf
+++ b/systemd/journald.conf
@@ -22,13 +22,13 @@ Storage=persistent
 RateLimitBurst=100000
 SystemMaxUse=3T
 #SystemKeepFree=
-#SystemMaxFileSize=
+SystemMaxFileSize=512M
 SystemMaxFiles=100000
 #RuntimeMaxUse=
 #RuntimeKeepFree=
 #RuntimeMaxFileSize=
 #RuntimeMaxFiles=100
-#MaxRetentionSec=
+MaxRetentionSec=2month
 #MaxFileSec=1month
 #ForwardToSyslog=yes
 #ForwardToKMsg=no
root@h1guardian1:/etc#

All logs are backed up to LDAS, so we will continue to have access to past logs if need be.

H1 General
camilla.compton@LIGO.ORG - posted 08:05, Tuesday 18 February 2020 (55148)
Shift transition to Day

TITLE: 02/18 Day Shift: 16:00-00:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Preventive Maintenance
OUTGOING OPERATOR: Jim
CURRENT ENVIRONMENT:
    SEI_CONF state: SC_OFF_NOBRSXY
    Wind: 2mph Gusts, 1mph 5min avg
    Primary useism: 0.02 μm/s
    Secondary useism: 0.20 μm/s
QUICK SUMMARY: Have been locked 6h50Just starting maintenance, Jim has finished PEM injections.

H1 General
jim.warner@LIGO.ORG - posted 07:59, Tuesday 18 February 2020 (55147)
Shift Summary

TITLE: 02/18 Owl Shift: 08:00-16:00 UTC (00:00-08:00 PST), all times posted in UTC
STATE of H1: Planned Engineering
INCOMING OPERATOR: Camilla
SHIFT SUMMARY: Quiet shift
LOG:
Lockloss when I arrive from an EQ in the Arctic.

9:23  Back to Observe

LHO FMCS
bubba.gateley@LIGO.ORG - posted 05:56, Tuesday 18 February 2020 (55146)
Arm Access Roads
Both arms are passable all the way to the end stations for vehicle traffic. X-2 has a slight buildup of tumbleweeds near the end station but not enough to cause concern. There are still blind spots on the corners, PLEASE DRIVE CAREFULLY. 
LHO General
thomas.shaffer@LIGO.ORG - posted 00:01, Tuesday 18 February 2020 (55145)
Ops Eve Shift Summary

TITLE: 02/18 Eve Shift: 00:00-08:00 UTC (16:00-00:00 PST), all times posted in UTC
STATE of H1: Observing at 120Mpc
INCOMING OPERATOR: Jim
SHIFT SUMMARY: Just lost lock from an earthquake. Nothing else to report.

H1 General
thomas.shaffer@LIGO.ORG - posted 20:05, Monday 17 February 2020 (55144)
Ops Mid Shift Report

Locked for 25 hours, no issues to report.

LHO VE
kyle.ryan@LIGO.ORG - posted 17:15, Monday 17 February 2020 (55143)
Access to MX OK for tomorrow's LN2 deliveries

Two deliveries (coordinated) scheduled for the Mid-X tomorrow -> I confirmed access (tumbleweeds) is acceptable.

H1 AOS (DetChar)
robert.schofield@LIGO.ORG - posted 17:05, Monday 17 February 2020 (55142)
After 48 Hz scattering mitigation, HAM3 requires an order of magnitude increase in vibration to affect DARM.

Summary: To help determine priorities for stray light mitigation during the O3-O4 break, I measured the residual coupling in the HAM3 area, and found it to be low. So I don’t think that HAM3 work to reduce light on the chamber walls is highest priority, though it would mitigate risk associated with alignment changes.

In the fall, we used impulse propagation delays and location-dependent beating from separated shakers to localize the source of 48 Hz scattering to HAM3 door areas (https://alog.ligo-wa.caltech.edu/aLOG/index.php?callRep=52184). We removed the 48 Hz peak from DARM by inserting black glass in the illuminator port, but we didn’t get the chance to measure the residual coupling, which had the potential to be fairly large because the light from the scraper baffle illuminated more of the door and nozzle than just the viewport (see above link, Figure 2).

 The figure below shows that I had to increase the vibration level at HAM3 by a factor of 10 between 35 and 50 Hz in order to increase the DARM noise floor. Also shown is the large broad 48 Hz peak and harmonics that appeared when the black glass was briefly removed without changing the settings.

These results suggest that blocking the remaining light from the PR2 scraper baffle and other stray light on HAM3 is not the highest priority (I would say HAM5-6 noise, likely from the septum, is). However, work on HAM3 would mitigate the risk of a coupling increase with alignment changes.

Non-image files attached to this report
H1 SEI
thomas.shaffer@LIGO.ORG - posted 17:01, Monday 17 February 2020 (55141)
HEPI Pump Trends - monthly

FAMIS9423

I don't notice anything major in these trends. You can see the CS HEPI servo restart, and some minor pressure changes.

Images attached to this report
H1 General
camilla.compton@LIGO.ORG - posted 16:07, Monday 17 February 2020 (55136)
Shift Summary - Day

TITLE: 02/18 Day Shift: 16:00-00:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Observing at 121Mpc
INCOMING OPERATOR: TJ
SHIFT SUMMARY: Locked 21 hours.
LOG:

LHO General
thomas.shaffer@LIGO.ORG - posted 16:03, Monday 17 February 2020 (55140)
Ops Eve Shift Transition

TITLE: 02/17 Eve Shift: 00:00-08:00 UTC (16:00-00:00 PST), all times posted in UTC
STATE of H1: Observing at 121Mpc
OUTGOING OPERATOR: Camilla
CURRENT ENVIRONMENT:
    SEI_CONF state: WINDY
    Wind: 11mph Gusts, 9mph 5min avg
    Primary useism: 0.03 μm/s
    Secondary useism: 0.20 μm/s
QUICK SUMMARY: Locked for almost 21 hours, calm environment.

H1 General
camilla.compton@LIGO.ORG - posted 12:24, Monday 17 February 2020 (55139)
Mid Shift Summary

Locked 17 hours. Range now up to 122Mpc!! (Maybe the Calibration measurements increased this?!) Wind < 10mph, Microseism 0.23 μm/s.

H1 SEI
camilla.compton@LIGO.ORG - posted 12:20, Monday 17 February 2020 (55138)
H1 ISI CPS Noise Spectra Check - Weekly
FAMIS 12887
From comparing to other weeks:
HAM4 has 90Hz and 108Hz peaks that aren't often there
HAM3 H2 has higher noise level
ETMY ST1 V3 has more high frequency peaks (30-60Hz)
BS ST2 V1 higher noise level
From script:
BS_ST2_CPSINF_V1_I high freq noise is high!
ETMY_ST2_CPSINF_V2 high freq noise is high!
Images attached to this report
H1 CAL
camilla.compton@LIGO.ORG - posted 11:37, Monday 17 February 2020 (55137)
Monday 19:00 UTC Calibration Measurements Completed
Winds below 15mph and  microseism at 0.23 μm/s at time of measurements.
New measurements are saved under /ligo/svncommon/CalSVN/aligocalibration/trunk/Runs/O3/H1/Measurements/FullIFOSensingTFs
2020-02-17_H1_DARM_OLGTF_LF_SS_5to1100Hz_15min.xml
2020-02-17_H1_PCALY2DARMTF_LF_SS_5t1100Hz_10min.xml
2020-02-17_H1_PCALY2DARMTF_BB_3min.xml
H1 AOS (SUS)
camilla.compton@LIGO.ORG - posted 10:25, Monday 17 February 2020 (55135)
Optical Lever 7 Day Trends

FAMIS 11257 Nothing has moved more than a few μrad in the last week. ETMY Pit has moved the most. ITMX and ETMX Pit are past or on thier -10μrad limit.

As sugested by Jeff K (alog 53633), I have also attached monthly trends.  The ndscope templates for these are in my home directory: /ligo/home/camilla.compton/Documents/Ndscope/OPLEVtrends1.yaml and OPLEVtrends2.yaml

Images attached to this report
H1 TCS
camilla.compton@LIGO.ORG - posted 10:09, Monday 17 February 2020 (55134)
TCS Chiller Water Level Top-Off - Weekly
TCS X
Before: 29.1, After: 30.0, Added: 200 mL  (This filter is green, but I think this is a known issue.)
TCS Y
Before: 9.3, After: 10.3 Added: 100 mL

FAMIS 11531

LHO FMCS
camilla.compton@LIGO.ORG - posted 09:48, Monday 17 February 2020 (55133)
Tumbleweed report

As we've had some wind over the weekend, I've scanned the cameras to give a heads up for access for tomorrows maintenance day. 

Y arm is clear down the arms. For trucks, it maybe be a tight squeeze going around MY and going around corner station onto y arm. (Photos linked) 

X arm is narrow but clear to MX but there are a few small blockages between MX and EX. (Photos linked) 

Images attached to this report
H1 General
camilla.compton@LIGO.ORG - posted 08:05, Monday 17 February 2020 (55132)
Shift transition to Day

TITLE: 02/17 Day Shift: 16:00-00:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Observing at 119Mpc
OUTGOING OPERATOR: Jim
CURRENT ENVIRONMENT:
    SEI_CONF state: WINDY
    Wind: 13mph Gusts, 9mph 5min avg
    Primary useism: 0.04 μm/s
    Secondary useism: 0.24 μm/s
QUICK SUMMARY: Locked 13 hours. We have planned Calibration measurements to take at 11am.