yannick.lecoeuche@LIGO.ORG - posted 00:09, Sunday 26 January 2020 (54724)
Ops OWL Shift Transition

Ops Shift Transition: 01/26/2020, Owl Shift 08:00–16:00 (00:00-08:00) - UTC (PT)

State of H1: Locked

Intent Bit: Observing

Weather: 5-15 mph wind

Primary 0.03 – 0.1Hz: 0.02 um/s

Secondary 0.1 – 0.3Hz: 0.3 um/s

Outgoing Operator: Jeff

Quick Summary: Locked and Observing for 1.5 hours, still microseism ringing down after an EQ in the Aleutians.

H1 General
jeffrey.bartlett@LIGO.ORG - posted 20:04, Saturday 25 January 2020 - last comment - 20:07, Saturday 25 January 2020(54722)
Ops Evening Mid-Shift Summary
   Recovering from Lockloss. Cause of lockloss unknown. 
   DRMI and PRMI not so good. Running Initial Alignment. 
Comments related to this report
jeffrey.bartlett@LIGO.ORG - 20:07, Saturday 25 January 2020 (54723)
  04:03 (20:03) Switch to EARTHQUAKE from incoming Mag5.7 from Japan.
H1 General
jeffrey.bartlett@LIGO.ORG - posted 16:07, Saturday 25 January 2020 (54721)
Ops Evening Shift Transition
Ops Shift Transition: 01/25/2020, Evening Shift 00:00 – 08:00 (16:00 -00:00) - UTC (PT)
State of H1: Locked at NLN. The range is 117.6Mpc
Intent Bit: Observing
Weather:  Skies are partly cloudy, with a chance of rain this evening into tomorrow morning. Winds are Calm. The temperatures are in the high 40s to low 50s. Tonight's temperatures are forecast to remain above freezing.     
Primary 0.03 – 0.1Hz: 0.03um/s
Secondary 0.1 – 0.3Hz: 0.4um/s
Outgoing Operator: Patrick
Quick Summary: All is well. No issues or problems to report.  

 

LHO General
patrick.thomas@LIGO.ORG - posted 15:58, Saturday 25 January 2020 (54720)
Ops Day Shift Summary
TITLE: 01/25 Day Shift: 16:00-00:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Observing at 116Mpc
INCOMING OPERATOR: Jeff
SHIFT SUMMARY: Remained locked and in observing the entire shift.
LOG:

20:25 UTC Changed SEI_CONF to EARTH_QUAKE for 5.3 magnitude earthquake in Puerto Rico.
20:44 UTC GRB-Short E361241
Set INJ_TRANS to INJECT_KILL.
Fermi
Trigger ID	601677816
TRIGGER_DUR:     0.064 [sec]
Stand Down
21:25 UTC Set INJ_TRANS to INJECT_SUCCESS.
21:26 UTC Changed SEI_CONF back to WINDY.
LHO General
patrick.thomas@LIGO.ORG - posted 12:01, Saturday 25 January 2020 (54719)
Ops Day Mid Shift Status
Have remained locked and in observing. No issues.
LHO General
patrick.thomas@LIGO.ORG - posted 08:17, Saturday 25 January 2020 (54718)
Ops Day Shift Start
TITLE: 01/25 Day Shift: 16:00-00:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Observing at 117Mpc
OUTGOING OPERATOR: Niko
CURRENT ENVIRONMENT:
    SEI_CONF state: WINDY
    Wind: 7mph Gusts, 6mph 5min avg
    Primary useism: 0.04 μm/s
    Secondary useism: 0.37 μm/s 
QUICK SUMMARY: No issues.
H1 General
yannick.lecoeuche@LIGO.ORG - posted 08:02, Saturday 25 January 2020 (54717)
Shift Summary - Owl

TITLE: 01/25 Owl Shift 08:00 – 16:00 (00:00-08:00), all times posted in UTC

STATE of H1: Observing

INCOMING OPERATOR: Patrick

SHIFT SUMMARY: Quiet shift, one GRB. Locked and Observing for just under 16 hours.

LOG: 

11:32 (03:32) GRB -- E361211, trigger duration too long

H1 General
yannick.lecoeuche@LIGO.ORG - posted 00:29, Saturday 25 January 2020 (54716)
Ops OWL Shift Transition

Ops Shift Transition: 01/25/2020, Owl Shift 08:00–16:00 (00:00-08:00) - UTC (PT)

State of H1: Locked

Intent Bit: Observing

Weather: 0-10 mph wind

Primary 0.03 – 0.1Hz: 0.01 um/s

Secondary 0.1 – 0.3Hz: 0.4 um/s

Outgoing Operator: Jeff

Quick Summary: Locked and Observing for 8 hours. Wind has been on the decline since hitting 50 mph earlier today

H1 AOS
jeffrey.bartlett@LIGO.ORG - posted 00:00, Saturday 25 January 2020 (54715)
Ops Evening Shift Summary
Ops Shift Log: 01/24/2020, Evening Shift 00:00 – 08:00 (16:00 - 00:00) Time - UTC (PT)
State of H1: Locked at NLN, Range 116.6Mpc
Intent Bit: Observing
Support: N/A
Incoming Operator: Niko
Shift Summary: After relocking, I cleared the SUS-ETMY_M0_TEST_P_OFFSET and SUS-ETMY_M0_TEST_Y_OFFSET SDF DIFFs. They had both changed by 0.05. Wind has been up and down all evening, but appears to be calming down a bit. No problems or concerns during the shift.
 
Activity Log: Time - UTC (PT)
00:00 (16:00) Take over from Corey
00:10 (16:10) Locked at NLN
00:14 (16:14) Cleared two SDF Diffs with ETM-Y M0 in pitch & yaw - & back in Observing
00:20 (16:20) Gerardo – Going to Mid-X
00:48 (16:48) Gerardo – Back from Mid-X
03:08 (19:08) Switch to EARTHQUAKE mode for mag 5.2 from Mexico
03:32 (19:32) Switch back to WINDY after EQ has passed
08:00 (00:00) Turn over to Niko
H1 General
jeffrey.bartlett@LIGO.ORG - posted 20:04, Friday 24 January 2020 (54714)
Ops Evening Mid-Shift Summary
   OK shift so far.

   Wind has been up and down with some gusts up in the high 30s to low 40mph. The range is holding around 115Mpc. Was in EARTHQUAKE mode for 24 minutes for mag5.2 from Mexico. Now back to WINDY. 

  
H1 General (Lockloss)
camilla.compton@LIGO.ORG - posted 16:39, Friday 24 January 2020 (54711)
Possible cause of "unknown locklosses"
Camilla, Jason, Sheila, Jenne
Looking at two short time periods where we've had lots of unknown lock losses, I have found that there seems to be a correlation with the time of the lockloss being within milliseconds of the PSL Ref Cav Transmitted photodiode and PSL PZT  oscillating (Yellow and green channels in attachment and zoomed version). I haven't fully investigated, but this seems to not happen when we know the reason of our lockloss, see EQ attachment for example when we lost lock from EQ and there is no FFS oscillation.
Times I have found: 2020-01-21 13:37:29 UTC, 2020-01-21 04:12:13 UTC, 2020-01-20 04:08:49 UTC, 2019-01-12 19:38:13  UTC, 2019-01-12 15:30:36  UTC, 2019-01-12 10:07:31  UTC, 2019-01-11 07:17:56  UTC,
Images attached to this report
H1 General
jeffrey.bartlett@LIGO.ORG - posted 16:10, Friday 24 January 2020 (54710)
Ops Evening Shift Transition
Ops Shift Transition: 01/24/2020, Evening Shift 00:00 – 08:00 (16:00 -00:00) - UTC (PT)
State of H1: Relocking
Intent Bit: Locking
Weather:  Skies are partly cloudy. There is a chance for more rain this evening. Winds are blowing up 25mph. The temperatures are currently in the mid to lower 50s         
Primary 0.03 – 0.1Hz: 0.04um/s
Secondary 0.1 – 0.3Hz: 0.3um/s
Outgoing Operator: Corey
Quick Summary: The IFO is being relocked after struggling against elevated winds and increasing microseism.  

 

LHO General
corey.gray@LIGO.ORG - posted 16:06, Friday 24 January 2020 (54701)
Day Operator Shift Summary

TITLE: 01/24 Day Shift: 16:00-00:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Observing at 117Mpc
INCOMING OPERATOR: Jeff
SHIFT SUMMARY:

Down for 1hr39min due to 6.7 Turkey EQ. (no trouble relocking).  Then had a sort of random lockloss (I'm blaming a nearby EQ in Canada!)

For relocking, had possible issues at FIND IR due to "low" flashes with the Y-arm (also see Jenne's alog about the BS & PR3).  Then had locklosses atleast 4x in row at CARM TO TR (this is when I called for assistance from Jenne), so finally ran an alignment, and so far it seems to be making its way back up to NLN *fingers crossed*

(NOTE:  Winds picked up quite a bit in the afternoon.)
LOG:

H1 FMP
travis.sadecki@LIGO.ORG - posted 15:50, Friday 24 January 2020 (54708)
VPW Desiccant cabinet relative humidity readouts Nov 2019 through Jan 2020

Relative humidity levels seem normal.  Nothing of concern for this quarter.

Non-image files attached to this report
H1 SUS
jenne.driggers@LIGO.ORG - posted 15:28, Friday 24 January 2020 - last comment - 14:07, Monday 27 January 2020(54706)
BS and PR3 wire heating filters are 25 min, not 4 min

[Corey, Jenne]

We've found that when the BS has integrated up a lot of ASC signal, but then we lose lock, it can take a long time for the flashes on the AS air camera to look symmetric again.  While looking at a series of locklosses from TR_CARM, Corey and I found that the let-the-integrator-decay filters in the M1 stage of the BS (which are labeled as 4min) are actually having the pitch output of the BS decay to zero over 25 (!) minutes.  Recall that these decay filters are to help with alignment issues due to wire heating, but that wire heating issues should mostly have been ameliorated by the wire baffles.  Even if we need these decay filters when we lose lock from NomLowNoise and high power, we shouldn't need them when we're losing lock from a cold IFO (eg. DRMI states).  Identical filters with long decay times are installed in PR3, but we don't use that optic for angular control, so it never needs to do any decaying.

The decay filters have names that say 4min, but the poles is at 6.6315e-4 Hz, which gives a ~1500 second decay time.  The pole frequency is at a surprisingly precise frequency, which if you include a 2*pi, makes it look like the decay time would be 240 seconds, or 4 min.  I suspect that the designer of these filters got mixed up and thought the values in Foton were in units of radians/sec, rather than 1/sec.

I don't know that this is what has been causing problems with locking, but it probably hasn't been helping.  I suppose that since we turn on MICH ASC once DRMI is locked, and before we start the carm offset reduction sequence, this residual BS offset shouldn't be a problem for TR_CARM (since it will be taken away by the MICH ASC).  It might have been causing problems with FIND IR for DIFF/Yarm, since the Yarm bounces off the BS to get out to its transmission PD.  

We should probably change the logic so that if we've lost lock from an early acquisition state, we just clear the BS pit history.  We can still use these decay filters for NomLowNoise locklosses, if they seem necessary.

Comments related to this report
jenne.driggers@LIGO.ORG - 16:27, Friday 24 January 2020 (54709)

After talking to Sheila and Jim, we all agree that we can probably get rid of these wire heating decay filters, since the new BS baffle was put in pre-O3 to further protect the wires from seeing any heating.  

In the first attached figure, we lose lock around 1300 seconds from a TR_CARM lockloss (so no power buildup). Very quickly, we have a transient that get through to the BS_M2_LOCK_P output, and so gets integrated in with the M1 Lock input.  But, since we've just lost lock, the ASC output isn't sent to the coils (because the lockloss trigger is stopping the signal), but after ~100 seconds the lockloss trigger is reset in the guardian, so we allow the decaying ASC signal back to the coils, and see a jump in the BS oplev signal.  The salient point is that as the coil output filter changes over 20 min, the BS oplev is also changing.  If the decay filter were compensating for wire heating, then the oplev should be more constant and flat.  Since it's not, we're pushing unneccessarily.

In the second attached figure, we lose lock from a 2 hour long Nominal Low Noise lock around 20 seconds.  No major transient in the M2 filter that gets sent to the M1 output, although the lockloss trigger again takes away the coil output for about a minute, during which time the optic swings a bit.  But, once the ASC outputs are again sent to the coils, we see the BS move as the coil output is changed.  I suspect that we'd be okay here also without having the long decay filters.  

Since we would only even potentially need the heating decay filters when losing lock from nominal low noise, it's a bit hard to do chopping tests with and without the filter, so probably we'll just try removing it entirely, and making the pitch filter banks operate the same way the yaws do (without any decay, just normal ramp-down).

Images attached to this comment
jenne.driggers@LIGO.ORG - 16:58, Friday 24 January 2020 (54712)OpsInfo

I have just changed ISC_DRMI to treat BS and PR3 pitch the same as yaw (as is done for all other suspensions) when clearing the ASC history in the DOWN state.  Next time we're out of Observing, we'll reload the ISC_DRMI guardian, so that we can (hopefully) see an improvement in some lock acqusition cases. If BS pointing is a real problem over the weekend, we can revert the DRMI guardian and reload it.

Still to be seen (fair game for an operator to look at over the weekend, otherwise I'll look next week) is whether the MICH BS ASC is in fact undoing / taking care of any leftover decay filter offset when we go through DRMI ASC, or whether this decay filter output has been causing trouble for us during the TR_CARM states.  I think that it's probably true that the MICH ASC is doing its job and pushing the BS where it needs to go (we do see improvements in buildups afterall), and that the TR_CARM locklosses are from something different. 

Even if the TR_CARM locklosses are unrelated to the BS pitch decay filters, it is still interesting that the TR_CARM locklosses seem to go away so easily after initial alignment.  Maybe something to check is where the optics were pointing when attempting and failing TR_CARM earlier in the afternoon before initial alignment, versus where the optics were pointing after initial alignment when we successfully got through TR_CARM.

jenne.driggers@LIGO.ORG - 16:58, Friday 24 January 2020 (54713)OpsInfo

I have just changed ISC_DRMI to treat BS and PR3 pitch the same as yaw (as is done for all other suspensions) when clearing the ASC history in the DOWN state.  Next time we're out of Observing, we'll reload the ISC_DRMI guardian, so that we can (hopefully) see an improvement in some lock acqusition cases. If BS pointing is a real problem over the weekend, we can revert the DRMI guardian and reload it.

Still to be seen (fair game for an operator to look at over the weekend, otherwise I'll look next week) is whether the MICH BS ASC is in fact undoing / taking care of any leftover decay filter offset when we go through DRMI ASC, or whether this decay filter output has been causing trouble for us during the TR_CARM states.  I think that it's probably true that the MICH ASC is doing its job and pushing the BS where it needs to go (we do see improvements in buildups afterall), and that the TR_CARM locklosses are from something different. 

Even if the TR_CARM locklosses are unrelated to the BS pitch decay filters, it is still interesting that the TR_CARM locklosses seem to go away so easily after initial alignment.  Maybe something to check is where the optics were pointing when attempting and failing TR_CARM earlier in the afternoon before initial alignment, versus where the optics were pointing after initial alignment when we successfully got through TR_CARM.

jenne.driggers@LIGO.ORG - 14:07, Monday 27 January 2020 (54758)

When doing this work on Friday, I had forgotten to ensure that the pitch gains get set back to their nonzero values in the guardian.  Corey fixed this, see thread in alog 54746.

LHO General (SEI)
corey.gray@LIGO.ORG - posted 10:45, Friday 24 January 2020 - last comment - 15:34, Friday 24 January 2020(54703)
10:21 H1 Lost Lock Due to 6.7 EQ In Turkey!

We are down due to a large earthquake in turkey.  No SEI or SUS trips.  But taking this opportunity for "noisy" activities while we wait for the Earth to calm down.

Comments related to this report
corey.gray@LIGO.ORG - 15:34, Friday 24 January 2020 (54707)

Notes after locking (this was a mid-shift post I forgot to post.  Ha.):

  • Had a large EQ (6.7 Turkey) take down all three detectors; H1 down at 10:21am LOCAL. 
  • Target Of Opportunity Window:  10:22 - 11:22 (for OMC dark meas, PSL computer retrieval, Forklifting around LVEA)
  • 11:22 Relocking started.
  • 12:00 Back to OBSERVING.
  • 11:40 Corner station winds start to hover around 20mph.