Reports until 08:42, Monday 20 January 2020
H1 General
cheryl.vorvick@LIGO.ORG - posted 08:42, Monday 20 January 2020 (54595)
OPS Owl Summary

TITLE: 01/20 Owl Shift: 08:00-16:00 UTC (00:00-08:00 PST), all times posted in UTC
STATE of H1: Lock Acquisition
INCOMING OPERATOR: Camilla
SHIFT SUMMARY: locked all shift
LOG:

Images attached to this report
H1 General
camilla.compton@LIGO.ORG - posted 08:15, Monday 20 January 2020 (54594)
Shift transition to DAY

TITLE: 01/20 Day Shift: 16:00-00:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Observing at 116Mpc
OUTGOING OPERATOR: Cheryl
CURRENT ENVIRONMENT:
    SEI_CONF state: WINDY
    Wind: 6mph Gusts, 4mph 5min avg
    Primary useism: 0.03 μm/s
    Secondary useism: 0.45 μm/s
QUICK SUMMARY: Just had a lockloss at 16:09 UTC, no obvious reason why yet. This might delay the calibration measurements that we have scheduled for 11am.

H1 AOS
cheryl.vorvick@LIGO.ORG - posted 04:40, Monday 20 January 2020 (54593)
OWL mid-shift update

<b>STATE of H1:</b> Observing at 117Mpc
<b>CURRENT ENVIRONMENT:</b>
    SEI_CONF state: USEISM
    Wind: 6mph Gusts, 4mph 5min avg
    Primary useism: 0.03 &mu;m/s
    Secondary useism: 0.39 &mu;m/s
<b>QUICK SUMMARY:</b>winds below 10mph with some gusts, range dropping, looks like it goes with a slight increase in useism

H1 General
cheryl.vorvick@LIGO.ORG - posted 01:46, Monday 20 January 2020 (54592)
OPS OWL Transition:

TITLE: 01/20 Owl Shift: 08:00-16:00 UTC (00:00-08:00 PST), all times posted in UTC
STATE of H1: Observing at 119Mpc
OUTGOING OPERATOR: Patrick
CURRENT ENVIRONMENT:
    SEI_CONF state: USEISM
    Wind: 4mph Gusts, 2mph 5min avg
    Primary useism: 0.03 μm/s
    Secondary useism: 0.42 μm/s
QUICK SUMMARY: locked in Observe

Images attached to this report
LHO General
patrick.thomas@LIGO.ORG - posted 00:15, Monday 20 January 2020 (54591)
Ops Eve Shift Summary
TITLE: 01/19 Eve Shift: 00:00-08:00 UTC (16:00-00:00 PST), all times posted in UTC
STATE of H1: Observing at 118Mpc
INCOMING OPERATOR: Cheryl
SHIFT SUMMARY: Two lock losses from observing, no obvious cause. Currently riding through 6.3 magnitude eq in South Georgia and the South Sandwich Is.
LOG:

00:10 UTC Lock loss from observing.
00:14 UTC Set SEI_CONF to WINDY. This might have helped the Y arm lock on green.
00:39 UTC Lock loss from RESONANCE. ISI BS stage 2 watch dog tripped.
00:46 UTC Lock loss from TURN_ON_BS_STAGE_2 (probably because it was tripped).
00:50 UTC Pausing at FIND_IR to untrip ISI BS stage 2. It went to DAMPED, but the nominal is HIGH_ISOLATED. Not sure if I should request HIGH_ISOLATED?
00:56 UTC Lock loss from FIND_IR
01:09 UTC Lock loss from PRMI_ASC
01:16 UTC Lock loss from ACQUIRE_DRMI_1F
01:17 UTC Pausing at READY. Setting ISI BS stage 2 request to HIGH_ISOLATED. It kept going back to DAMPED. Set SEI_BS to FULLY_ISOLATED. It went to FULLY_ISOLATED.
01:21 UTC Hit INIT. SEI_BS went to ISOLATED_DAMPED.
01:23 UTC Relocking.
01:32 UTC Lock loss from CARM_150_PICOMETERS. Pausing at READY to step out of control room.
01:41 UTC Set SEI_CONF to USEISM
01:43 UTC Relocking.
02:19 UTC NLN. No intervention.
02:21 UTC Accepted CALCS SDF differences. Observing.

02:35 UTC Verbal notification of a magnitude 5.3 incoming earthquake from Guam. Is on the borderline of not doing anything on the EQ response zones plot. Going to leave SEI configuration alone.

04:08 UTC Lock loss from observing.
04:37 UTC Lock loss from DHARD_WFS.
05:19 UTC NLN. No intervention.
05:20 UTC Accepted CALC SDF differences. Observing.

07:04 UTC Took SEI_CONF to EARTH_QUAKE for 6.3 eq in South Georgia and the South Sandwich Is.
LHO General
patrick.thomas@LIGO.ORG - posted 21:22, Sunday 19 January 2020 (54590)
Observing
05:20 UTC. SDF differences attached.
Images attached to this report
LHO General
patrick.thomas@LIGO.ORG - posted 20:33, Sunday 19 January 2020 (54589)
Lock loss
04:08 UTC
LHO General
patrick.thomas@LIGO.ORG - posted 20:01, Sunday 19 January 2020 (54588)
Ops Eve Mid Shift Status
No issues since recovering from the lock loss at the beginning of the shift.
LHO General
patrick.thomas@LIGO.ORG - posted 18:24, Sunday 19 January 2020 (54587)
Observing
02:21 UTC. SDF differences attached.
Images attached to this report
LHO General
patrick.thomas@LIGO.ORG - posted 16:11, Sunday 19 January 2020 (54586)
Ops Eve Shift Start
TITLE: 01/19 Eve Shift: 00:00-08:00 UTC (16:00-00:00 PST), all times posted in UTC
STATE of H1: Lock Acquisition
OUTGOING OPERATOR: Camilla
CURRENT ENVIRONMENT:
    SEI_CONF state: USEISM
    Wind: 11mph Gusts, 8mph 5min avg
    Primary useism: 0.04 μm/s
    Secondary useism: 0.46 μm/s 
QUICK SUMMARY: Just lost lock.
H1 General
camilla.compton@LIGO.ORG - posted 16:03, Sunday 19 January 2020 (54583)
Shift Summary - Day

TITLE: 01/19 Day Shift: 16:00-00:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Observing at 118Mpc
INCOMING OPERATOR: Patrick
SHIFT SUMMARY: Strugggled to align the IFO this shift but now been locked for 1h45.
LOG:

H1 General
camilla.compton@LIGO.ORG - posted 13:55, Sunday 19 January 2020 - last comment - 14:53, Sunday 19 January 2020(54584)
Lockloss at 14:18 UTC
Ongoing long recovery from Jim's lockloss (alog 54580).
Not use why all the optics seem so badly aligned. I couldn't get PRMI to lock. It was very off in Pitch but I kept loosing lock adjusting it. Keita by phone helped me get through initial alignment, by aligning BS while watching ASC-AS_A_DC, and at 21:40 we have finally locked DRMI!
Livingston called to say they are down for such a long period due to storms, microseism, wind AND a complete power outage.
Comments related to this report
camilla.compton@LIGO.ORG - 14:53, Sunday 19 January 2020 (54585)ISC
  • 22:19 NLN (finally!) SDF diifs attached:
    • There was lots of small 10-32 ones in CALCS (image) which have bee seen in the last few locks. I accepted.
    • There was 2 for ETMY_M0_TEST_OFFSETS, from when I exited out of initial alignment (sorry!). Offsets currently off, so I reverted.
    • There are 2 from ALS_Y_WFS I don''t know about. Maybe changed when Jim was troubleshooting, I accepted as it seems like they are still in use (photo). Tagging ISC?!
  • 22:30 Observing
Images attached to this comment
H1 General
camilla.compton@LIGO.ORG - posted 08:47, Sunday 19 January 2020 - last comment - 09:48, Sunday 19 January 2020(54581)
Shift transition to DAY

TITLE: 01/19 Day Shift: 16:00-00:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Lock Acquisition
OUTGOING OPERATOR: Jim
CURRENT ENVIRONMENT:
    SEI_CONF state: USEISM
    Wind: 2mph Gusts, 1mph 5min avg
    Primary useism: 0.04 μm/s
    Secondary useism: 0.75 μm/s
QUICK SUMMARY:  Having trouble locking Y arm with no light on AS AIR or ALS_Y_WFS_A_DC. It seems that the ALS-Y_PZT1_TRIG_THRESH or the REFL_SERVO may not be set correctly so I may call in the Cavalry.

 

Comments related to this report
camilla.compton@LIGO.ORG - 09:48, Sunday 19 January 2020 (54582)

After tweeking the ETMY and TMSY to get the dot of light on WFS_A_DC as central as I could, Increase flashes worked its magic and got ALs locked.

H1 General
jim.warner@LIGO.ORG - posted 08:20, Sunday 19 January 2020 (54580)
Shift Summary

TITLE: 01/19 Owl Shift: 08:00-16:00 UTC (00:00-08:00 PST), all times posted in UTC
STATE of H1: Lock Acquisition
INCOMING OPERATOR: Camilla
SHIFT SUMMARY: Eq lockloss, then trouble with ALSY
LOG:
14:18 Lockloss caused by high microseism and earthquake seismic transition

I spent the next hour waiting for the ground to calm down, then waiting for ALS locking to fail. I could help lock the X arm after waiting for way too long, but no real visible light on the ALSY camera. I know this is a problem we've run into before, but couldn't find the fix in either Jenne's troubleshooting document or the alog, or even the H1 troubleshooting ops wiki. The only clue I have is that when the Xarm is locked the green wfs qpds have spots that are centered and the yarm A qpd doesn't have a spot and the B is not centered.

LHO General
patrick.thomas@LIGO.ORG - posted 00:00, Sunday 19 January 2020 (54579)
Ops Eve Shift Summary
TITLE: 01/18 Eve Shift: 00:00-08:00 UTC (16:00-00:00 PST), all times posted in UTC
STATE of H1: Observing at 9Mpc
INCOMING OPERATOR: Jim
SHIFT SUMMARY: Remained locked entire shift. Knocked briefly out of observing by squeezer.
LOG:

03:16 UTC Knocked out of observing by squeezer.
03:18 UTC Clicked INIT on SQZ_MANAGER.
03:19 UTC Back to observing.
LHO General
patrick.thomas@LIGO.ORG - posted 20:05, Saturday 18 January 2020 (54578)
Ops Eve Mid Shift Status
Have remained locked. Knocked out of observing briefly by squeezer. Microseism is still slowly trending down.
LHO General
patrick.thomas@LIGO.ORG - posted 16:22, Saturday 18 January 2020 (54577)
Ops Eve Shift Start
TITLE: 01/18 Eve Shift: 00:00-08:00 UTC (16:00-00:00 PST), all times posted in UTC
STATE of H1: Observing at 119Mpc
OUTGOING OPERATOR: Camilla
CURRENT ENVIRONMENT:
    SEI_CONF state: USEISM
    Wind: 7mph Gusts, 6mph 5min avg
    Primary useism: 0.05 μm/s
    Secondary useism: 1.11 μm/s 
QUICK SUMMARY: Microseism is trending back down but still very high. No other issues at present.
H1 General
camilla.compton@LIGO.ORG - posted 16:05, Saturday 18 January 2020 (54573)
Shift Summary - Day

TITLE: 01/19 Day Shift: 16:00-00:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Observing at 121Mpc
INCOMING OPERATOR: Patrick
SHIFT SUMMARY: Locked 26h 30. Microseism still high.
LOG:

16:08-16:11 with Jim, tried changing SEI_DIFF from CORNER_DIFF_CPS to DOWN to reduce glitches, this didn't seem to help, maybe looked worse, so reverted to CORNER_DIFF_CPS
16:15 Scott, Chris and Tyler out to MX to work on tumbleweeds.
17:29 MY air handler alarm (see alog 54572)
20:45 Tyler, Chris, Scott have finished with tumbleweeding for the day!
Displaying reports 36221-36240 of 89212.Go to page Start 1808 1809 1810 1811 1812 1813 1814 1815 1816 End