Ops Day Shift Start

TITLE: 11/05 Day Shift: 1530-0030 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Lock Acquisition
OUTGOING OPERATOR: Ryan S
CURRENT ENVIRONMENT:
    SEI_ENV state: USEISM
    Wind: 11mph Gusts, 6mph 3min avg
    Primary useism: 0.03 μm/s
    Secondary useism: 0.60 μm/s 
QUICK SUMMARY: Lost lock about an hour ago, trying to lock DRMI now. Had two lock losses and relocked during the last shift. Looks like the MSR WAP is stuck. Stand down query failure, I'll restart that now. The useism is up again, somehow we locked last night though. Today's plan is to Observe!

Comments related to this report
thomas.shaffer@LIGO.ORG - 08:33, Wednesday 05 November 2025 (87969)

Just lost lock at Close_Beam_Diverters. We had two successful relocks last night that went through this state just fine, so I hoped this would go well again today. I'll step through close beam diverters next time.

We tend to have more automated relocks at night, and I wonder the eleveated 1-3Hz ground motion that we see during the day might be shaking us just enough during the day.

Images attached to this comment
LHO General
corey.gray@LIGO.ORG - posted 21:59, Tuesday 04 November 2025 (87958)
Tues EVE Ops Summary

TITLE: 11/05 Eve Shift: 0030-0600 UTC (1630-2200 PST), all times posted in UTC
STATE of H1: Preventive Maintenance
INCOMING OPERATOR: Ryan S
SHIFT SUMMARY:

Bit of a rough start to the shift with H1 having issues getting to NLN.  Managed to finally get to Observing after a few hours of work (see earlier alogs).  Violins were high (but not off the DARM FOM), and have steadily been dropping over the 2+hrs of this lock.

Had a LOW SQZ_PMC voltage, but squeezer lockloss and automatic relock brought the voltage back to a better state (70+ volts).
LOG:

Images attached to this report
H1 SQZ (SQZ)
corey.gray@LIGO.ORG - posted 20:27, Tuesday 04 November 2025 (87967)
H1 Back To Observing: Post Maintenance, Earthquakes, Rising Microseism, Beam Diverter Worries, and LOW SQZ PZT Voltage

At the beginning of the shift H1 had a lockloss during late stages of ISC_LOCK where we slowly stepped through states and found the lockloss occurred at CLOSING BEAM DIVERTERS (see Elenna's alog 87961).  

Took a couple of locking attempts for H1 to return to this same point of ISC_LOCK locking.  (during this time is when Jenne noticed/addressed the Power Scaling issue (see alog 87965).  

While locking chatted with Oli and they mentioned for some of their locklosses, they would go state by state, but ALSO if there was a 1Hz ring-up during these states, they would go to "ASC HiGn" AND then wait there a few minutes until the 1Hz ring up (seen on the PR_GAIN channel on PRMI.sb of nuc30  +  ASC-INP1_P_INMON on nuc29).

So for this 2nd attempt of getting through CLOSE BEAM DIVERTERS this shift, went through the states:

Made it to NLN, but could not go to Observing for (2) (I believe) separate reasons. 

1)  SQZ_OPO_LR:   "CMB EXC is ON" and SDF Diffs (see attachement #1).  For the SDF Diffs, I reverted these with no problems. 

At this point, I tried to go to OBSERVING, but could not.

2) Then noticed for SQZ_PMC, we had the notification:  "PMC PZT volts low".  Thought I would address this, but then I was able to take H1 to OBSERVING, so I kicked the can and went to OBSERVING instead of addressing the low voltage.  See attachement #2 for PMC Voltage over the last week.  Still have the notification for the low pmc voltage.

Images attached to this report
LHO VE (VE)
gerardo.moreno@LIGO.ORG - posted 18:50, Tuesday 04 November 2025 - last comment - 17:46, Monday 08 December 2025(87966)
Kobelco Compressor and Dry Air Skid Functionality Test

I ran the dry air system thru its quarterly test, FAMIS task.  The system was started around 8:20 am local time, and turned off by 11:15 am.  System achieved a dew point of -50 oF, see attached photo taken towards the end of the test.  Noted that we may be running low on oil at the Kobelco compressor, checking with vendor on this.  Picture of oil level is while system is off.

Images attached to this report
Comments related to this report
gerardo.moreno@LIGO.ORG - 17:46, Monday 08 December 2025 (88431)VE

(Jordan, Gerardo)

We added some oil to the Kobelco reservoir whith the compressor off.  We added about 1/2 gallon to get the level to come up to the half mark, see attached photo of level, photo was taken after the compressor had been running for 24+ hours.  Level now is at nominal.

Images attached to this comment
H1 ISC
jenne.driggers@LIGO.ORG - posted 18:47, Tuesday 04 November 2025 (87965)
Laser Power Scaling confused by IM4 response time

[Corey, Jenne]

We lost lock on the way up (not at all sure why, we hadn't yet gotten to the state we were worried about, but microseism is on an upward trend again), and when the IFO was relocking, the new power scaling (from alog 87806) did something funny.  

The guardian is set up to use the IM4 output if the IMC is locked, and the IMC input power otherwise.  It looks like this has worked successfully for the whole week since it was implemented, except for right now.

The MC2 Trans Sum was plenty high (but had only just gotten there), correctly indicating that the IMC was locked less than a second before the guardian had to decide whether the IMC was locked, so the Laser power guardian took for the power scaling the IM4 trans output.  However, it looks like the laser power guardian read that IM4 value, while IM4 trans was still settling, since it has some whitening / dewhitening.  

Once I realized that the power scaling was wonky, I just set the offset to 2, so that we could get back to locking while I investigated, which worked.  Since the laser power guardian does reset that value every time there's a change to the laser power, the guardian has already picked it up and put in the more correct value of 1.8.  

To prevent this from happening again, I put in a bit of logic to the set_power_scale() function of the LASER_PWR, such that if IM4 trans reads less than 1W, just use the input power as we used to do.  We basically never request 1 W or less from the PSL and also are locking the full IFO, so this should be fine.

I tested it by bringing the LASER_PWR guardian to 3W (it used the IM4 trans as it should), and then down to 1W (which ends up as about 0.9W at IM4 trans), and the guardian correctly used the input power for the power scale.  So, I think it should work fine.

LHO VE (VE)
gerardo.moreno@LIGO.ORG - posted 18:23, Tuesday 04 November 2025 (87963)
FAMIS Task Completed for Corner Station Turbo Pump Stations

Functionality test for the corner station turbo pumps, see notes below:

Output mode cleaner tube turbo station;
Scroll pump hours: 7284.7
Turbo pump hours: 7306
Crash bearing life is at 100%

X beam manifold turbo station;
Scroll pump hours: 3387.3
Turbo pump hours: 3391
Crash bearing life is at 100%

Y beam manifold turbo station;
Scroll pump hours: 4157.7
Turbo pump hours: 2826
Crash bearing life is at 100%

FAMIS tasks 31339, 31331 and 31347.

H1 ISC (Lockloss)
elenna.capote@LIGO.ORG - posted 16:53, Tuesday 04 November 2025 - last comment - 18:56, Tuesday 04 November 2025(87961)
Close Beam Diverters guardian state causing locklosses

We have had multiple locklosses right near the end of the locking sequence around CLOSE BEAM DIVERTERS and OMC WHITENING. Today, we held at different states while locking. First, we pasued at MAX POWER while we waited for the R waves of a few different earthquakes to pass. Then, we proceeded successfully through to LASER NOISE SUPPRESSION. There are large glitches in this state, probably because of the CARM loop, so we stayed in the state to wait for the glitches to die down. Then, Corey selected ADS TO CAMERAS. This state proceeded fine, but we saw the 1 Hz starting to ring up. Corey selected the ASC Hi Gain script button on the seismic page to damp the 1 Hz back down. It damped down. We next went to INJECT SQUEEZING, which was fine. We waiting again about a minute after the state finished. Finally, Corey selected CLOSE BEAM DIVERTERS and we lost lock. Here is the guardian log so we can see the timestamps of each step.

We had the same lockloss earlier, it's logged at being from "omc whitening" but usually the beam diverters state is very fast so we are in omc whitening by the time the lockloss happens. Attached is the suspension signals from both locklosses. It looks like something rings up in DARM.

 

2025-11-05_00:36:48.787114Z ISC_LOCK [LASER_NOISE_SUPPRESSION.run] ezca: H1:IMC-REFL_SERVO_IN2GAIN => -29
2025-11-05_00:36:48.787719Z ISC_LOCK [LASER_NOISE_SUPPRESSION.run] ezca: H1:IMC-REFL_SERVO_FASTGAIN => -16
2025-11-05_00:37:24.445085Z ISC_LOCK REQUEST: ADS_TO_CAMERAS
2025-11-05_00:37:24.445085Z ISC_LOCK calculating path: LASER_NOISE_SUPPRESSION->ADS_TO_CAMERAS
2025-11-05_00:37:24.446434Z ISC_LOCK new target: ADS_TO_CAMERAS
2025-11-05_00:37:24.501243Z ISC_LOCK EDGE: LASER_NOISE_SUPPRESSION->ADS_TO_CAMERAS
2025-11-05_00:37:24.501532Z ISC_LOCK calculating path: ADS_TO_CAMERAS->ADS_TO_CAMERAS
2025-11-05_00:37:24.505287Z ISC_LOCK executing state: ADS_TO_CAMERAS (578)
2025-11-05_00:37:24.506308Z ISC_LOCK [ADS_TO_CAMERAS.enter]
2025-11-05_00:37:24.532550Z ISC_LOCK [ADS_TO_CAMERAS.main] ezca: H1:GRD-CAMERA_SERVO_REQUEST => CAMERA_SERVO_ON
2025-11-05_00:37:24.533290Z ISC_LOCK [ADS_TO_CAMERAS.main] camera servo guardian state
2025-11-05_00:37:24.533992Z ISC_LOCK [ADS_TO_CAMERAS.main] ezca: H1:ASC-AS_A_RF36_Q_YAW_SW1 => 8
2025-11-05_00:37:24.785056Z ISC_LOCK [ADS_TO_CAMERAS.main] ezca: H1:ASC-AS_A_RF36_Q_YAW => ON: OFFSET
2025-11-05_00:38:24.227696Z ISC_LOCK [ADS_TO_CAMERAS.run] ezca: H1:SUS-ETMX_L2_DRIVEALIGN_P2L_SPOT_GAIN => 3.13
2025-11-05_00:38:24.228345Z ISC_LOCK [ADS_TO_CAMERAS.run] ezca: H1:SUS-ETMY_L2_DRIVEALIGN_P2L_SPOT_GAIN => 4.89
2025-11-05_00:38:24.230162Z ISC_LOCK [ADS_TO_CAMERAS.run] ezca: H1:SUS-ETMX_L2_DRIVEALIGN_Y2L_SPOT_GAIN => 4.85
2025-11-05_00:38:24.230577Z ISC_LOCK [ADS_TO_CAMERAS.run] ezca: H1:SUS-ETMY_L2_DRIVEALIGN_Y2L_SPOT_GAIN => 0.78
2025-11-05_00:39:40.380293Z ISC_LOCK REQUEST: INJECT_SQUEEZING
2025-11-05_00:39:40.383415Z ISC_LOCK calculating path: ADS_TO_CAMERAS->INJECT_SQUEEZING
2025-11-05_00:39:40.386240Z ISC_LOCK new target: INJECT_SQUEEZING
2025-11-05_00:39:40.448133Z ISC_LOCK EDGE: ADS_TO_CAMERAS->INJECT_SQUEEZING
2025-11-05_00:39:40.448133Z ISC_LOCK calculating path: INJECT_SQUEEZING->INJECT_SQUEEZING
2025-11-05_00:39:40.453186Z ISC_LOCK executing state: INJECT_SQUEEZING (580)
2025-11-05_00:39:40.453467Z ISC_LOCK [INJECT_SQUEEZING.enter]
2025-11-05_00:39:40.471153Z ISC_LOCK [INJECT_SQUEEZING.main] ezca: H1:GRD-SQZ_MANAGER_REQUEST => FREQ_DEP_SQZ
2025-11-05_00:39:40.472228Z ISC_LOCK [INJECT_SQUEEZING.main] timer['CheckSqz'] = 90
2025-11-05_00:39:40.473316Z ISC_LOCK [INJECT_SQUEEZING.main] ezca: H1:GRD-SUS_PI_REQUEST => PI_DAMPING
2025-11-05_00:39:40.720211Z ISC_LOCK [INJECT_SQUEEZING.run] USERMSG 0: SQZ_MANAGER: has notification
2025-11-05_00:39:45.281174Z ISC_LOCK [INJECT_SQUEEZING.run] USERMSG 0: SQZ_MANAGER: has notification
2025-11-05_00:40:51.377382Z ISC_LOCK REQUEST: CLOSE_BEAM_DIVERTERS
2025-11-05_00:40:51.378087Z ISC_LOCK calculating path: INJECT_SQUEEZING->CLOSE_BEAM_DIVERTERS
2025-11-05_00:40:51.378087Z ISC_LOCK new target: CLOSE_BEAM_DIVERTERS
2025-11-05_00:40:51.459548Z ISC_LOCK EDGE: INJECT_SQUEEZING->CLOSE_BEAM_DIVERTERS
2025-11-05_00:40:51.459721Z ISC_LOCK calculating path: CLOSE_BEAM_DIVERTERS->CLOSE_BEAM_DIVERTERS
2025-11-05_00:40:51.464167Z ISC_LOCK executing state: CLOSE_BEAM_DIVERTERS (590)
2025-11-05_00:40:51.465760Z ISC_LOCK [CLOSE_BEAM_DIVERTERS.enter]
2025-11-05_00:40:51.475467Z ISC_LOCK [CLOSE_BEAM_DIVERTERS.main] Closing REFL beam diverter
2025-11-05_00:40:51.476845Z ISC_LOCK [CLOSE_BEAM_DIVERTERS.main] ezca: H1:SYS-MOTION_C_BDIV_A_CLOSE => 1
2025-11-05_00:40:51.476939Z ISC_LOCK [CLOSE_BEAM_DIVERTERS.main] Closing AS beam diverter
2025-11-05_00:40:51.478119Z ISC_LOCK [CLOSE_BEAM_DIVERTERS.main] ezca: H1:SYS-MOTION_C_BDIV_D_CLOSE => 1
2025-11-05_00:40:51.478494Z ISC_LOCK [CLOSE_BEAM_DIVERTERS.main] ezca: H1:VID-CAM16_EXP_REQ => 36000
2025-11-05_00:40:51.579758Z ISC_LOCK [CLOSE_BEAM_DIVERTERS.main] ezca: H1:VID-CAM16_EXP_SET => 1
2025-11-05_00:40:51.579758Z ISC_LOCK [CLOSE_BEAM_DIVERTERS.main] Closing POP beam diverter
2025-11-05_00:40:51.580545Z ISC_LOCK [CLOSE_BEAM_DIVERTERS.main] ezca: H1:SYS-MOTION_C_BDIV_B_CLOSE => 1
2025-11-05_00:40:53.156310Z ISC_LOCK [CLOSE_BEAM_DIVERTERS.run] Unstalling IMC_LOCK
2025-11-05_00:40:53.347649Z ISC_LOCK [CLOSE_BEAM_DIVERTERS.run] Unstalling VIOLIN_DAMPING
2025-11-05_00:40:53.521338Z ISC_LOCK JUMP target: LOCKLOSS
2025-11-05_00:40:53.521845Z ISC_LOCK [CLOSE_BEAM_DIVERTERS.exit]
2025-11-05_00:40:53.582367Z ISC_LOCK JUMP: CLOSE_BEAM_DIVERTERS->LOCKLOSS
2025-11-05_00:40:53.582367Z ISC_LOCK calculating path: LOCKLOSS->CLOSE_BEAM_DIVERTERS
2025-11-05_00:40:53.585523Z ISC_LOCK new target: DOWN
2025-11-05_00:40:53.590140Z ISC_LOCK executing state: LOCKLOSS (2)

 

Images attached to this report
Comments related to this report
jenne.driggers@LIGO.ORG - 18:56, Tuesday 04 November 2025 (87962)

I double checked that the squeezer wasn't doing anything (just in case waiting longer than 1 min might help disentangle things).  The SQZ_MANAGER was hanging out in state 69, where it asks the SQZ_ANG_ADJUST guardian to go to 'ADJUST_SQZ_ANG_ADF'. On the way to that state, the last thing the sqz manager had done was tell the SQZ_ANG_ADJUST guardian to go to WAIT_SQZ_AND_ADF, which just sits and waits for ISC_LOCK to get to NomLowNoise.  So, I think I've convinced myself the lockloss is nothing to do with the squeezer.

I plotted several channels (starting from the lockloss 'scope).  I'm still not really sure why the test mass L2 channels get a bit fuzzy about one second before the beam diverters close, but I think it's a red herring anyway.  The real thing that seems to be interesting is that the HAM1 GS13s see a kick (due to the beam diverter moving) right when DARM sees a kick (the kick that Elenna pointed out).  

So, I agree with Elenna and Corey's plan for now, to do the last few locking states slowly, then doing CLOSE_BEAM_DIVERTERS by hand to figure out which beam diverter is causing the problem.  I also think it could be interesting to trend the GS13s for HAMs 1 and 6 for other locks (the other one tonight that we lost lock, as well as a few that were successful), to see if the kicks have gotten bigger or if they are the same size as always.

I also think that if closing the beam diverters causes another lockloss, we should just manual past the CLOSE_BEAM_DIVERTERS state, run for the night with them open, and tag DetChar.  I'm pretty sure we've shown that they no longer really matter if they are open or closed, so I think we'd rather try to have some data with the beam diverters open than none at all.

Images attached to this comment
H1 CAL (CAL)
anthony.sanchez@LIGO.ORG - posted 16:40, Tuesday 04 November 2025 (87953)
PCAL EX measurement

Dr. Dripta B. and I went to EX today to do a PCAL End Station measurement with PS4 using the  T1500062 ES Power Sensor RR Meas : Procedures & Log.
I took a picture of the beam spots before we started, and after we were done
We ran Miriam's fantastic shell tool & left her some feed back written in the margins of the 2.2 section of the T1500062 Proc & Log document linked above.

We tried to run the measurement right at the end station but we didn't know that NDS servers were having a problem this week.
I eventually changed the server to be h1daqnds1 port 8088 to get the data instead.
       
Command Ran:
python generate_measurement_data.py --WS PS4 --date 2025-11-03
Reading in config file from python file in scripts
../../../Common/O4PSparams.yaml
PS4 rho, kappa, u_rel on 2025-11-03 corrected to ES temperature 299.5 K :
-4.7017855975867215 -0.0002694340454223 2.686163396659873e-05
Copying the scripts into tD directory...
Connected to h1daqnds1
martel run
reading data at start_time:  1446313243
reading data at start_time:  1446313659
reading data at start_time:  1446313992
reading data at start_time:  1446314497
reading data at start_time:  1446314910
reading data at start_time:  1446315256
reading data at start_time:  1446315430
reading data at start_time:  1446316080
reading data at start_time:  1446316490
Ratios: -0.46104301054554775 -0.4663040860974578
writing nds2 data to files
finishing writing
Background Values:
bg1 =        9.224674; Background of TX when WS is at TX
bg2 =        4.512480; Background of WS when WS is at TX
bg3 =        9.191238; Background of TX when WS is at RX
bg4 =        4.365167; Background of WS when WS is at RX
bg5 =        9.279967; Background of TX
bg6 =        0.429854; Background of RX

The uncertainty reported below are Relative Standard Deviation in percent 

Intermediate Ratios
RatioWS_TX_it      = -0.461043;
RatioWS_TX_ot      = -0.466304;
RatioWS_TX_ir      = -0.455583;
RatioWS_TX_or      = -0.461207;
RatioWS_TX_it_unc  = 0.084627;
RatioWS_TX_ot_unc  = 0.080522;
RatioWS_TX_ir_unc  = 0.093808;
RatioWS_TX_or_unc  = 0.083107;
Optical Efficiency
OE_Inner_beam                      = 0.988311;
OE_Outer_beam                      = 0.989318;
Weighted_Optical_Efficiency        = 0.988814;

OE_Inner_beam_unc                  = 0.058828;
OE_Outer_beam_unc                  = 0.054324;
Weighted_Optical_Efficiency_unc    = 0.080074;

Martel Voltage fit:
Gradient      = 1637.051728;
Intercept     = 0.515075;


 Power Imbalance = 0.988718;

Endstation Power sensors to WS ratios::
Ratio_WS_TX                        = -1.078345;
Ratio_WS_RX                        = -1.392858;

Ratio_WS_TX_unc                    = 0.050215;
Ratio_WS_RX_unc                    = 0.044908;

=============================================================
============= Values for Force Coefficients =================
=============================================================

Key Pcal Values :
GS           =      -5.135100; Gold Standard Value in (V/W)             
WS           =      -4.701786; Working Standard Value             

costheta     =      0.988362; Angle of incidence
c            =      299792458.000000; Speed of Light
             
End Station Values : 
TXWS         =        -1.078345; Tx to WS Rel responsivity (V/V)
sigma_TXWS   =        0.000541; Uncertainity of Tx to WS Rel responsivity (V/V)
RXWS         =        -1.392858; Rx to WS Rel responsivity (V/V)
sigma_RXWS   =        0.000626; Uncertainity of Rx to WS Rel responsivity (V/V)

e            =        0.988814; Optical Efficiency
sigma_e      =        0.000792; Uncertainity in Optical Efficiency

Martel Voltage fit : 
Martel_gradient         =        1637.051728; Martel to output channel (C/V)
Martel_intercept   =        0.515075; Intercept of fit of     Martel to output (C/V)

Power Loss Apportion : 
beta          =        0.998895; Ratio between input and output (Beta)  
E_T          =        0.993842; TX Optical efficiency 
sigma_E_T          =        0.000398; Uncertainity in TX Optical efficiency 
E_R          =        0.994941; RX Optical Efficiency 
sigma_E_R          =        0.000398; Uncertainity in RX Optical efficiency 

Force Coefficients : 
FC_TxPD          =        7.895132e-13; TxPD Force Coefficient 
FC_RxPD          =        6.181524e-13; RxPD Force Coefficient 
sigma_FC_TxPD          =        5.093350e-16; TxPD Force Coefficient 
sigma_FC_RxPD          =        3.738196e-16; RxPD Force Coefficient 
data written to ../../measurements/LHO_EndX/tD20251104/

This produced the following plots:

Martel_Voltage_test.png
WS_at_TX.png

WS_at_RX.png
WS_at_RX_BOTH_BEAMS.png

Running the the Following command makes the Trends plots for the ES measurement:
python pcalPublishReportsV5.py LHO_EndX tD20251104

LHO_EndX_PD_ReportV5.pdf  

All of this can be found at the PCAL git lab repo.  

 

Images attached to this report
Non-image files attached to this report
LHO General
thomas.shaffer@LIGO.ORG - posted 16:32, Tuesday 04 November 2025 (87959)
Ops Day Shift End

TITLE: 11/05 Day Shift: 1530-0030 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Preventive Maintenance
INCOMING OPERATOR: Corey
SHIFT SUMMARY: Maintenance Tuesday. Relocking hasn't been very successful so far. CO2Y was having IR faulting issues (alog87952), then we had a lock loss that occurred when we got to the Close_Beam_Diverters state, which we saw last week (alog87877). Now we are having a few earthquakes rolling through as we sit in max power. We don't want to advance until the ground stop shaking a bit so we can keep high gain asc on. 
LOG:                                                                                        

Start Time System Name Location Lazer_Haz Task Time End
16:06 ISC Matt CR n IMC 60W meas. 17:01
16:07 SYS Mitchell, Randy LVEA n Mega cleanroom sock install 17:15
16:10 FAC Kim, Nellie LVEA n Tech clean 18:03
16:11 VAC Jordan, Travis, Janos EY n Purge air line install 19:59
16:12 VAC Gerardo LVEA, Mech room n Run Kobelco, pump CP1 LN2 line, test turbo pumps 20:35
16:12 CDS Betsy CER n Putting stickers on racks 16:23
16:20 FAC Tyler, Rays Site n Septic tank inspection and pumping 17:59
16:22 CDS Fil EX n Connecting fibers to prep for RFM test 17:27
16:31 PCAL Dripta, Tony PCAL lab LOCAL Check on lab 16:47
16:38 SYS Betsy LVEA n Check on sock and domes 17:14
16:44 VAC Norco CP1 n LN2 fill 18:49
16:44 FAC Chirs, pest LVEA, outbuildings n Pest control 17:49
16:49 PCAL Tony, Dripta EX YES PCAL calibration meas. 19:31
17:07 CDS Betsy CER n Removing stickers from ISCC3&4 17:16
17:17 VAC Norco CP5 MX n LN2 fill 19:14
17:31 CDS Fil LVEA n Cable pull around HAM2/3 20:05
17:34 - Richard LVEA n Checking on a few things 17:57
17:34 SUS Oli CR n PRM, SRM estimator measurements 20:08
17:40 PEM Robert, Sam LVEA n Mounting accel. 18:49
17:45 SYS Randy LVEA n Taking measurements of HAM3 and BSC2 areas 18:27
17:49 FAC Chris LVEA n FAMIS checks 18:32
17:49 PSL Jason LVEA n Walking the PSL chiller lines, FAMIS 18:01
17:57 SQZ Sheila, Matt CR n OM2 hot OMC meas. 20:08
17:59 FAC Tyler, Geotech MY n CEBEX surverying 23:24
18:03 FAC Kim EX yes Tech clean 19:17
18:04 FAC Nellie EY n Tech clean 19:20
18:05 CDS Erik EY, EX n Grabbing equipment from EY, doing RFM test at EX 19:18
18:13 CDS Marc LVEA n Helping Fil with cables at HAM2/3 20:05
18:14 IO Rahul Opt Lab LOCAL JAC testing 19:07
18:55 PEM Robert, Sam LVEA n More accelerometer moving 20:28
19:20 FAC Rana, Mike, Tour LVEA n Tour 20:12
19:41 FAC Kim FCES n Tech clean 19:42
19:51 FAC Randy XTube n Filling cracks 23:02
20:47 PCAL Tony PCAL lab LOCAL Wrapping up meas. 21:32
20:52 TCS Ryan C LVEA n Turn TCS CO2Y back on 20:53
20:58 PCAL Rene, Alicia PCAL lab LOCAL Check out lab with Tony 21:44
21:09 TCS TJ LVEA N Reset CO2Y laser 21:24
22:19 SPI Corey, Ryan S Opt Lab n Optics cleaning 23:29
23:04 PEM Robert, Sam Arms n BTE cell phone signal testing 02:04
H1 PSL
ryan.short@LIGO.ORG - posted 16:29, Tuesday 04 November 2025 (87960)
PSL Cooling Water pH Test - Monthly

FAMIS 27570

pH of PSL chiller water was measured to be between 10.0 and 10.5 according to the color of the test strip.

LHO General
corey.gray@LIGO.ORG - posted 16:21, Tuesday 04 November 2025 (87956)
Tues EVE Ops Transition

TITLE: 11/05 Eve Shift: 0030-0600 UTC (1630-2200 PST), all times posted in UTC
STATE of H1: Preventive Maintenance
OUTGOING OPERATOR: TJ
CURRENT ENVIRONMENT:
    SEI_ENV state: EARTHQUAKE
    Wind: 10mph Gusts, 6mph 3min avg
    Primary useism: 0.52 μm/s
    Secondary useism: 0.35 μm/s 
QUICK SUMMARY:

Maintenance Day Recovery continues through the hand-off, but H1 locking is also being impacted by strong seismic activity (Russia EQs + microseism also inching back up).  Violins look elevated as well, so there has been attention given to them.

Hand-Offs from TJ:

X1 SUS (SUS)
ibrahim.abouelfettouh@LIGO.ORG - posted 16:07, Tuesday 04 November 2025 (87954)
BRDs Installed Further Away - Modes Measured

Ibrahim, Rahul

In short, it appears that BRD damping is working.

Images attached to this report
H1 General
matthewrichard.todd@LIGO.ORG - posted 16:04, Tuesday 04 November 2025 (87955)
OMC scan with SQZ beam and hot OM2-- 20251104

M. Todd, S. Dwyer


We wanted to heat up OM2 and retake an OMC scan to get another measurement to compare against our models, as Sheila had the idea to use the SQZ beam which we know well at ZM5 and measure the overlap to the OMC. We were able to take some data at the very end of the maintanence period but we were having issues for a long time and gave up on having the OM2 hot for the measurement and let it cool down so that relocking could be on time today.

We did all the usual steps of turning the DC centering loops on for the OMs and put the OMC ASC on to center on the QPDs. In the future, here's what we should do.

Step 0 -- Turn on OM2 1hr45min before measurement

Go to IFO_OUT > OM2  and in the input box below "POWER_SET" in the bottom panel, set the power to 4.6. Wait 1hr45min.

Step 1 -- SQZ guardian to LOCKED_SEED_DITHER

Also make sure that there is no IFO power when you go to take your measurement.

Make sure the beam diverter is closed and that the seed launch power is around 75 (if not you may have to pico the half wave plate by going to SQZT0 and clicking on the lambda/2 near "Seed Launch"). Then take the SQZ manager to LOCKED_SEED_DITHER and make sure that OPO locks. You should also take the FC to misaligned, as this was causing flashes in our DCPDs we did not want and were confusing us.

Step 2 -- Open beam diverter and close DC centering

By opening the beam diverter and the fast shutter you should be able to get light on the AS_A and AS_B QPDs so that you can close the DC3 and DC3 centering loops. Then you can take the OMC guardian to OMC ASC and make sure the beam is centered on the OMC QPDs. The NSUM values we saw with the SQZ beam was around 0.001, so there isn't a ton of light on them.

--- You should be able to measure an OMC scan now  ---
If the HG10 peak is really high compared to the OM2 you may try closing the OMC LSC loop and waiting for things to settle before unlocking and remeasuring.

The OMC scans from today were not very good as the HG10 modes were much too high and don't make a good quadratic estimate of the mode-mismatch.

Images attached to this report
H1 TCS
thomas.shaffer@LIGO.ORG - posted 14:00, Tuesday 04 November 2025 - last comment - 16:13, Tuesday 04 November 2025(87952)
CO2Y IR sensor in and out of fault, resat cable

The IR sensor for CO2Y was intermittently going into fault. I resat the connector on the sat box and it seems to be okay now.

Today during maintenance the CO2Y laser tripped off 3 times. The first one we figured was due to cable pulling activity in the area, the second was a bit more of a mystery, and the third made us think there was definitely something wrong. Ryan C restarted the first two at the control box, needing to power cycle it at least once each time. The third time I went out there and noticed the IR fault light going on and off. I touched the cable that goes to the IR sensor itself and the lights on the IR satellite box went red. Simply placing my finger on the cable near the connector on the box was enough to bring it into fault. I checked the connector there and it had some play in it, so I tried to seat it a bit better and then it seemed to not be as sensitive to me touching it. I turned the key off and on again and it was good to go.

Because this last trip happened while we were powering up to 25W, there was about 20 minutes or so when CO2X was on at its nominal annular power, but CO2Y was off (~2107-2131UTC). Perhaps this is an interesting bit of time for someone to look at?

We ended up losing lock when powering up to 60W. Perhaps I should have waited longer after CO2Y was back to let it "catch up" to ITMX's thermal state.

 

Comments related to this report
thomas.shaffer@LIGO.ORG - 16:13, Tuesday 04 November 2025 (87957)

Picture of the box with me touching the cable I moved around.

Images attached to this comment
H1 SUS
oli.patane@LIGO.ORG - posted 13:41, Tuesday 04 November 2025 - last comment - 16:00, Tuesday 11 November 2025(87950)
Most of the rest of the measurements for H1SUSPRM for Estimator

Last week (87801) Jeff took a bunch of transfer function measurements for PRM for the PRM L, P, and Y estimators. There were some he wasn't able to take:

- H1ISIHAM2 to H1SUSPRM M1 for all dofs with DAMP L, P, and Y all with 20% gain

- H1ISIHAM2 to H1SUSPRM M1 for all dofs with DAMP Y at 20% gain

- H1SUSPRM M1 to M1 for V, R, P, Y with DAMP Y at 20% gain

Today I was able to get the first two bullet points done

Measurements:

First, I made sure the SUSPOINT matrix had the correct values for driving PRM, which it did. 

First set (L P Y DAMP gain at 20%):

L, P and Y DAMP gains were set to 20% of their nominal values, so they were set to -0.1, and T, V, and R were left at their nominal -0.5 gain values. 

Measurements can be found in 

/ligo/svncommon/SusSVN/sus/trunk/HSTS/H1/PRM/Common/Data/2025-11-04_1800_H1ISIHAM2_ST1_PRMSusPoint_M1LPYDampingGain0p1_WhiteNoise_*_0p02to50Hz.xml r12766

Second set (Y DAMP gain at 20%):

After those measurements were taken, I set the L and P DAMP gains back to their nominal values of -0.5 and took another set of SUSPOINT measurements with only the Y gain at 20%.

Those measurements can be found in 

/ligo/svncommon/SusSVN/sus/trunk/HSTS/H1/PRM/Common/Data/2025-11-04_1930_H1ISIHAM2_ST1_PRMSusPoint_M1YawDampingGain0p1_WhiteNoise_*_0p02to50Hz.xml r12767

I ran out of time and wasn't able to finish the four M1 to M1 dofs that were left for the reduced Y damping, so we'll have to get those next week.

I also wasn't able to get in any measurements for SRM, but that's okay since we're not in a rush.

Comments related to this report
oli.patane@LIGO.ORG - 16:00, Tuesday 11 November 2025 (88067)

complete PRM measurements: 88063

LHO VE (VE)
gerardo.moreno@LIGO.ORG - posted 00:45, Wednesday 29 October 2025 - last comment - 18:32, Tuesday 04 November 2025(87814)
CP1 LN2 Fill Line Pump Down

(Jordan V., Gerardo M.)
Connected valves to be able to pump down the CP1 LN2 fill line, we started with 26 micron of pressure and we pumped down on the system with a scroll pump for most of the maintenance period, we stopped the pump down of the fill line at around 11:45 AM with pressure down to 4 micron.  Both valves were closed before turning off the scroll pump.  Hoses, adapter and valves remain connected, we intent to visit this item next week again.

 

 

 

Images attached to this report
Comments related to this report
gerardo.moreno@LIGO.ORG - 18:32, Tuesday 04 November 2025 (87964)VE

Today all hardware used to pump down the fill line was removed, initial reading was that of 3 microns, but after all the items were removed the reported internal pressure went up to 7 microns.  We'll take another reading next Tuesday.

H1 SUS (SEI)
jeffrey.kissel@LIGO.ORG - posted 14:48, Tuesday 28 October 2025 - last comment - 15:57, Tuesday 11 November 2025(87801)
H1SUSPRM M3, M2, and M1 Drive to M1 Response TFs to inform Estimator Models
J. Kissel

Gathered H1SUSPRM M3, M2, and M1 Drive to M1 Response TFs to inform the "drive" models for a future H1SUSPRM estimator. I'll post the locations / file names in the comments. Here in the main entry, I discuss the state of the control system for H1 SUS PRM so we understand with how much salt would should take these measurements.

Executive summary :: there are some side quests we can launch -- especially on the actuation side of this suspension -- if we think that these measurements reveal "way too much cross coupling for an estimator to work." The first things I'd attack would be 
    - the frequency-dependent and scalar gain differences *between* the nominal low noise state of the coil drivers and the state we need to characterize the suspension. 
    - the very old coil balancing, which was done *without* first compensating for any frequency-dependent gain differences in the channels at the frequency used to balance the coils (see LHO:9453 for measurement technique.)

Here's the detailed summary of all the relevant things for these measurements:
    - The suspension was ALIGNED, with alignment offsets ON, with slider values (P,Y) = (-1629.783, -59.868) ["urad"] 
        :: ALIGNED is needed (rather than just DAMPED [where the alignment sliders are OFF] or MISALIGNED where extra large alignment offsets are ON; per discussion of how the alignment impacts the calibration in LHO:87102)
        :: the usual caveats about the slider calibration, which is still using the [DAC ct / "urad"] gains from LHO:4563).

    - The M1 damping loop were converted to Level 2.0 loop shaping in Jan 2023; LHO:66859, nominally designed to have an EPICs gain of -1.0. However in Aug 2023, the EPICs gains were lowered to -0.5, and have been that way for most of O4, and remain that way now. For all of these measurements, I set the L, P and Y gains to -0.1; the "20% of nominal" gain mantra we've used for the HLTS estimators. I also gathered *almost* all the measurements again with only the Y gain at -0.1, but ran out of time to complete that set for comparison. 

    - Even though it was maintenance day, when we typically turn site-wide sensor correction OFF, I manually turned ON sensor correction for ISI HAM2 to get better coherence below 1 Hz (using instructions in LHO:87790)

    - The M3 L to M3 P filter (and gain) in the M3 DRIVEALIGN frequency-dependent matrix is OFF, per LHO:87523. 

    - There are (M3 P to M3 L) = 1.7 and (M3 Y to M3 L) = 0.52 scalar gains ON in to off-diagonal elements of the M3 DRIVEALIGN matrix whose purpose is change the center of P and Y actuation to be around where the IFO's beam spot typically is.

    - There is a set of M1 L to M1 P filters, "M1L_M3P" and "invM1P_M3P," in the M1 DRIVEALIGN matrix, with a EPICs gain of -1. I think these came from LHO:42549. The measurements I took aren't impacted by this, as I drove from the M1 TEST bank which does not send excitation through the DRIVEALIGN Matrix. HOWEVER, we'll definitely need to consider this when we model the ISC drive which *does* go through the M1 DRIVEALIGN matrix.

    - All M1, M2, and M3 stages of OSEM PDs sat amp whitening filters have been upgraded with ECR E2400330's filter design, and compensated accordingly. 
        :: M1 stage LHO:85463
        :: M2 & M3 stages LHO:87103

    - All M1, M2, and M3 stages of OSEM PDs have been calibrated via the ISI GS13s, and calibrated in the ALIGNED state (LHO:87231)

    - In order to get decent coherence over the band of interest for the M3, M2, and M1 drives, I had to drive the suspension actuators in their highest range state, which is different from the state the IFO usually needs.
        :: M1 = State 1 "LP OFF" (a Triple TOP Driver)
        :: M2 = State 2 "Acq ON, LP OFF" (An ECR E1400369 Triple Acquisition Driver "TACQ" modified for an extra 10x actuation strength. Modified in Sep 2013 LHO:7630)
        :: M3 = State 2 "Acq ON, LP OFF" (An ECR E1400369 Triple Acquisition Driver "TACQ" modified for an extra 10x actuation strength. Modified in Sep 2014 LHO:13956)

        :: The nominal state for the switches are M1 = State 2 "LP ON," M2 = M3 = State 3 "ACQ OFF, LP ON."

    - No actuator channels have had any precise compensation for their coil driver's frequency response in any state.
        :: M1 state 1 channels are all compensated with (z:p) = (0.9 : 30.9996) Hz
        :: M2 state 2 channels are all compensated with (z:p) = (64.9966 : 13) Hz
        :: M3 state 2 channels are all compensated with (z:p) = (64.9966 : 13) Hz

    - There are scalar "coil balancing" non-unity magnitude gains on each of the M2 and M3 stage channels, but it's the same values that have been in play since Jan 2014 (LHO:9419; so, after the M2 TACQ driver mod, but before the M3 TACQ driver mod). There is no coil balancing gains on the M1 stage, they're all either +/- 1.0.

Comments related to this report
jeffrey.kissel@LIGO.ORG - 14:52, Tuesday 28 October 2025 (87808)SEI
Here's the complete data set with L, P, and Y damping loop gains set to -0.1, with the T, V, and R gains at -0.5.

    /ligo/svncommon/SusSVN/sus/trunk/HSTS/H1/PRM/SAGM1/Data/
        2025-10-28_H1SUSPRM_M1toM1_CDState1_M1LPYDampingGain0p1_WhiteNoise_L_0p02to50Hz.xml
        2025-10-28_H1SUSPRM_M1toM1_CDState1_M1LPYDampingGain0p1_WhiteNoise_P_0p02to50Hz.xml
        2025-10-28_H1SUSPRM_M1toM1_CDState1_M1LPYDampingGain0p1_WhiteNoise_R_0p02to50Hz.xml
        2025-10-28_H1SUSPRM_M1toM1_CDState1_M1LPYDampingGain0p1_WhiteNoise_T_0p02to50Hz.xml
        2025-10-28_H1SUSPRM_M1toM1_CDState1_M1LPYDampingGain0p1_WhiteNoise_V_0p02to50Hz.xml
        2025-10-28_H1SUSPRM_M1toM1_CDState1_M1LPYDampingGain0p1_WhiteNoise_Y_0p02to50Hz.xml

    /ligo/svncommon/SusSVN/sus/trunk/HSTS/H1/PRM/SAGM2/Data/
        2025-10-28_H1SUSPRM_M2toM1_CDState2_M1LPYDampingGain0p1_WhiteNoise_L_0p02to50Hz.xml
        2025-10-28_H1SUSPRM_M2toM1_CDState2_M1LPYDampingGain0p1_WhiteNoise_P_0p02to50Hz.xml
        2025-10-28_H1SUSPRM_M2toM1_CDState2_M1LPYDampingGain0p1_WhiteNoise_Y_0p02to50Hz.xml

    /ligo/svncommon/SusSVN/sus/trunk/HSTS/H1/PRM/SAGM3/Data/
        2025-10-28_H1SUSPRM_M3toM1_CDState2_M1LPYDampingGain0p1_WhiteNoise_L_0p02to50Hz.xml
        2025-10-28_H1SUSPRM_M3toM1_CDState2_M1LPYDampingGain0p1_WhiteNoise_P_0p02to50Hz.xml
        2025-10-28_H1SUSPRM_M3toM1_CDState2_M1LPYDampingGain0p1_WhiteNoise_Y_0p02to50Hz.xml
jeffrey.kissel@LIGO.ORG - 14:53, Tuesday 28 October 2025 (87809)
Here's the almost entirely complete data set for *only* the Y damping loop gain set to -0.1, and L, T, V, R, P set to -0.5.

    /ligo/svncommon/SusSVN/sus/trunk/HSTS/H1/PRM/SAGM1/Data/
        2025-10-28_H1SUSPRM_M1toM1_CDState1_M1YawDampingGain0p1_WhiteNoise_L_0p02to50Hz.xml
        2025-10-28_H1SUSPRM_M1toM1_CDState1_M1YawDampingGain0p1_WhiteNoise_T_0p02to50Hz.xml
        [did not get V]
        [did not get R]
        [did not get P]
        [did not get Y]

    /ligo/svncommon/SusSVN/sus/trunk/HSTS/H1/PRM/SAGM2/Data/
        2025-10-28_H1SUSPRM_M2toM1_CDState2_M1YawDampingGain0p1_WhiteNoise_L_0p02to50Hz.xml
        2025-10-28_H1SUSPRM_M2toM1_CDState2_M1YawDampingGain0p1_WhiteNoise_P_0p02to50Hz.xml
        2025-10-28_H1SUSPRM_M2toM1_CDState2_M1YawDampingGain0p1_WhiteNoise_Y_0p02to50Hz.xml

    /ligo/svncommon/SusSVN/sus/trunk/HSTS/H1/PRM/SAGM3/Data/
        2025-10-28_H1SUSPRM_M3toM1_CDState2_M1YawDampingGain0p1_WhiteNoise_L_0p02to50Hz.xml
        2025-10-28_H1SUSPRM_M3toM1_CDState2_M1YawDampingGain0p1_WhiteNoise_P_0p02to50Hz.xml
        2025-10-28_H1SUSPRM_M3toM1_CDState2_M1YawDampingGain0p1_WhiteNoise_Y_0p02to50Hz.xml
oli.patane@LIGO.ORG - 13:45, Tuesday 04 November 2025 (87951)

Took some more of the meaurements for PRM estimator here: 87950

Those four M1 to M1 with DAMP Y at 20% for V R P and Y are still needed

oli.patane@LIGO.ORG - 15:57, Tuesday 11 November 2025 (88066)

Here's the list of estimator measurements for PRM: 88063

Displaying reports 3621-3640 of 89075.Go to page Start 178 179 180 181 182 183 184 185 186 End