Displaying reports 36601-36620 of 89200.Go to page Start 1827 1828 1829 1830 1831 1832 1833 1834 1835 End
Reports until 12:11, Tuesday 31 December 2019
H1 General (CAL, GRD, IOO, PEM, SEI, SQZ, SUS)
cheryl.vorvick@LIGO.ORG - posted 12:11, Tuesday 31 December 2019 (54194)
OPS Mid-Day Update

As of 20:00 UTC, half way through the shift, these are the activities that have taken place this morning:

Winds are between 5mph and 40mph, and have been between 5mph and 35mph for the last 4 hours (16:00-20:00 UTC).

Images attached to this report
H1 General
cheryl.vorvick@LIGO.ORG - posted 09:36, Tuesday 31 December 2019 (54193)
OPS Day Transition

TITLE: 12/31 Day Shift: 16:00-00:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Corrective Maintenance
OUTGOING OPERATOR: Ed
CURRENT ENVIRONMENT:
    SEI_CONF state: WINDY
    Wind: 28mph Gusts, 20mph 5min avg
    Primary useism: 0.09 μm/s
    Secondary useism: 0.33 μm/s
QUICK SUMMARY:  recovering from dolphin crash, X arm in green is locked, working on Y arm alignment

H1 CAL (CAL, DetChar)
john.zweizig@LIGO.ORG - posted 08:27, Tuesday 31 December 2019 (54192)
gds calibration pipelines restarted

I have restarted the gds calibration pipelinesat about 15:54 UTC. Before the restart the pipeline latency was about 25s and after the restart it is reduced to <5s.

H1 General
edmond.merilh@LIGO.ORG - posted 08:06, Tuesday 31 December 2019 (54191)
Shift Summary - Owl

TITLE: 12/31 Owl Shift: 08:00-16:00 UTC (00:00-08:00 PST), all times posted in UTC
STATE of H1: Corrective Maintenance
INCOMING OPERATOR: Cheryl
SHIFT SUMMARY:

Still recovering from Corner station crash

Cheryl is in early to help with recovery

LOG:

H1 General
edmond.merilh@LIGO.ORG - posted 04:19, Tuesday 31 December 2019 - last comment - 08:02, Tuesday 31 December 2019(54186)
Mid-Shift Report: H1 Down 11:57UTC

All time in UTC:

There seems to have been a corner station system wide crash. H1 had been locked for 34:08

More news as it happens.....

Images attached to this report
Comments related to this report
edmond.merilh@LIGO.ORG - 08:02, Tuesday 31 December 2019 (54189)

12:28 Dave is beginning his remote magic

13:06 All WDs reset

13:07 Rotation stage seemed to be stuck at 47.8 W

  • Re-Initialized LASER_PWR Guardian node at 2W - successful

13:08 re-locking mode cleaner

  • IMC won't lock
  • following steps in WIKI
    • Called Cheryl for assistance

 

 

H1 CDS
david.barker@LIGO.ORG - posted 04:15, Tuesday 31 December 2019 - last comment - 04:55, Tuesday 31 December 2019(54187)
Corner station models crash

Most corner station models have crashed, I'm capturing logs before starting a recovery.

Images attached to this report
Comments related to this report
david.barker@LIGO.ORG - 04:33, Tuesday 31 December 2019 (54188)

Opened FRS14005

david.barker@LIGO.ORG - 04:55, Tuesday 31 December 2019 (54190)

I have captured all dmesg, messages and dolphin logs. I then restarted the models on all corner station front ends (except PSL and SUSAUX) in the order: SUS, SEI, ISC.

After the restarts, I cleared all DIAG_RESETS and DAQ-DC counters.

The only red item outstanding is the CW injection on h1calinj, that usually takes about 10 minutes to restart.

I'm handing everything over to Ed for IFO recovery.

Images attached to this comment
H1 General
edmond.merilh@LIGO.ORG - posted 00:22, Tuesday 31 December 2019 (54185)
Shift Transition - Owl

TITLE: 12/31 Owl Shift: 08:00-16:00 UTC (00:00-08:00 PST), all times posted in UTC
STATE of H1: Observing at 112Mpc
OUTGOING OPERATOR: Corey
CURRENT ENVIRONMENT:
    SEI_CONF state: WINDY
    Wind: 19mph Gusts, 17mph 5min avg
    Primary useism: 0.04 μm/s
    Secondary useism: 0.34 μm/s
QUICK SUMMARY:

LHO General
corey.gray@LIGO.ORG - posted 00:01, Tuesday 31 December 2019 (54184)
EVE Shift Summary

TITLE: 12/31 Eve Shift: 00:00-08:00 UTC (16:00-00:00 PST), all times posted in UTC
STATE of H1: Observing at 109Mpc
INCOMING OPERATOR: Ed
SHIFT SUMMARY:

LHO General
corey.gray@LIGO.ORG - posted 16:31, Monday 30 December 2019 (54183)
Transition to Eve Summary

TITLE: 12/30 Eve Shift: 00:00-08:00 UTC (16:00-00:00 PST), all times posted in UTC
STATE of H1: Observing at 112Mpc
OUTGOING OPERATOR: Jim
CURRENT ENVIRONMENT:
    SEI_CONF state: WINDY
    Wind: 12mph Gusts, 9mph 5min avg
    Primary useism: 0.06 μm/s
    Secondary useism: 0.45 μm/s 

Microseism took a step up about 10hrs ago.  Winds were hovering up near 10mph, but appear to be trending down from that.  
QUICK SUMMARY:

H1's been locked 22.5+hrs w/ a range just above 110Mpc.

Recent Operator Note:  At the next Lockloss, contact John Z (email/cell any time) for restart of calibration pipelines.

H1 General
jim.warner@LIGO.ORG - posted 15:59, Monday 30 December 2019 (54182)
Shift Summary

TITLE: 12/30 Day Shift: 16:00-00:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Observing at 112Mpc
INCOMING OPERATOR: Corey
SHIFT SUMMARY: Nothing happened
LOG:

Was locked when I got here, there was a tiny bit of wind for a while, handing off to Corey.

H1 General
edmond.merilh@LIGO.ORG - posted 07:57, Monday 30 December 2019 (54180)
Shift Summary - Owl

TITLE: 12/30 Owl Shift: 08:00-16:00 UTC (00:00-08:00 PST), all times posted in UTC
STATE of H1: Observing at 113Mpc
INCOMING OPERATOR: Jim
SHIFT SUMMARY:

LOG:

H1 General
edmond.merilh@LIGO.ORG - posted 03:47, Monday 30 December 2019 (54179)
Mid-Shift Report
H1 PSL
edmond.merilh@LIGO.ORG - posted 01:16, Monday 30 December 2019 (54178)
PSL Weekly Report - 10 Day Trends FAMIS #10641-42

Shown are trends back to approx 12/16. All appear to be nominally normal.

Images attached to this report
H1 General
camilla.compton@LIGO.ORG - posted 23:59, Sunday 29 December 2019 (54173)
Shift Summary - Eve

TITLE: 12/30 Eve Shift: 00:00-08:00 UTC (16:00-00:00 PST), all times posted in UTC
STATE of H1: Observing at 114Mpc
INCOMING OPERATOR: Ed
SHIFT SUMMARY:  Locked 6hours. Porcupine has been wandering around the car park again tonight!
LOG: On next lockloss, operators should notify John Zweizig by email so the Calibration pipeline can be restarted.

H1 General
camilla.compton@LIGO.ORG - posted 17:18, Sunday 29 December 2019 - last comment - 14:08, Monday 30 December 2019(54174)
Lockloss at 00:27 UTC

No obvious reason, microseism still elevated.

Comments related to this report
camilla.compton@LIGO.ORG - 17:57, Sunday 29 December 2019 (54176)SUS
01:48 NLN and Observing with no operator intervention
Some of the suspension saturations are approaching yellow/orange (attached image). Is there anything that should be done upon lockloss to make them happier?
Images attached to this comment
jenne.driggers@LIGO.ORG - 14:08, Monday 30 December 2019 (54181)

Thanks for noticing small details like this!  There isn't anything that needs to be done at this time. 

Displaying reports 36601-36620 of 89200.Go to page Start 1827 1828 1829 1830 1831 1832 1833 1834 1835 End