TITLE: 12/02 Eve Shift: 00:00-08:00 UTC (16:00-00:00 PST), all times posted in UTC STATE of H1: Lock Acquisition INCOMING OPERATOR: Jeff SHIFT SUMMARY: Lockloss might be from an earthquake in Japan. Still struggling to relock. After two lock losses in the CARM reduction states, moved to initial alignment. Could not get SRY to acquire in initial alignment and gave up on it to try relocking again. I moved the SEI_CONF state from USEISM to WINDY because the green arms were more stable in WINDY, but have now set it back to USEISM. LOG: 01:24 UTC Dick leaving site. 03:56 UTC Dropped out of observing by squeezer 03:58 UTC Hit INIT on SQZ_MANAGER 04:00 UTC Back to observing 04:40 UTC Changed SEI_CONF from USEISM to EARTH_QUAKE for 4.1 mag earthquake in Canada. 04:41 UTC Dropped out of observing by H1_ISI_ETMY SDF 04:45 UTC Changed SEI_CONF back to USEISM. SDF differences cleared by this. 04:48 UTC Back to observing. 05:06 UTC Changed SEI_CONF to EARTH_QUAKE for 5.6 mag earthquake in Japan. Knocked out of observing by SDF differences again. 05:09 UTC Lock loss. Sudden spike in seismic signal. 05:11 UTC Putting ISC_LOCK in DOWN until ground settles. 05:12 UTC Set observatory mode to earthquake 05:36 UTC SEI_CONF to USEISM 05:38 UTC ISC_LOCK request to NLN. Observatory mode to locking. 05:44 UTC Aligning Y arm for green by hand. Moved ETMY in pitch. 05:52 UTC Lock loss from locking ALS 05:52 UTC SEI_CONF to WINDY 05:59 UTC Lock loss from TURN_ON_BS_STAGE2 06:13 UTC Lock loss from CARM_150_PICOMETERS 06:27 UTC Lock loss from CARM_OFFSET_REDUCTION 06:29 UTC Proceeding to initial alignment 06:45 UTC Set observatory mode to aligning 06:51 UTC Seems stuck on ACQUIRE_SRY ALIGN_IFO to DOWN misaligned SRM AS-AS_C is already well centered realigned SRM requested SRC_ALIGN_OFFLOADED changed request to SRC_ALIGN hit down, init for align_ifo moved SRM in pitch and yaw moved SRM to 1 hour ago skipping rest of initial alignment set observatory mode to locking 07:17 UTC Script moved automatically to ACQUIRE_PRMI 07:18 UTC PRMI locked 07:20 UTC DRMI locked 07:26 UTC Lockloss from CARM_OFFSET_REDUCTION 07:41 UTC Lockloss from DARM_TO_RF 07:42 UTC Set SEI_CONF to USEISM 07:45 Lock loss from FIND_IR 07:56 UTC Lock loss from CARM_TO_TR 07:59 UTC Lock loss from LOCKING_ALS
Dropped briefly out of observing by squeezer. No other issues.
TITLE: 12/01 Day Shift: 16:00-00:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Observing at 112Mpc
INCOMING OPERATOR: Patrick
SHIFT SUMMARY: H1 lost lock due to local EQ, relocking had some issues, listed below, currently H1 has been in Observe for almsot an hour.
Relocking/Shift Highlights:
Relocking LOG:
TITLE: 12/01 Eve Shift: 00:00-08:00 UTC (16:00-00:00 PST), all times posted in UTC
STATE of H1: Observing at 117Mpc
OUTGOING OPERATOR: Cheryl
CURRENT ENVIRONMENT:
SEI_CONF state: USEISM
Wind: 7mph Gusts, 5mph 5min avg
Primary useism: 0.03 μm/s
Secondary useism: 0.76 μm/s
QUICK SUMMARY: Microseism is still high. No other issues.
H1 knocked out of lock by a 3.6M EQ in Packwood, WA, about 140 miles from the site.
I've been damping violin modes, and the ndscopes for each mode on an optic are very helpful, and since I need to watch more than one mode. I've updated the ndscope files for:
TITLE: 12/01 Day Shift: 16:00-00:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Observing at 117Mpc
OUTGOING OPERATOR: Ed
CURRENT ENVIRONMENT:
SEI_CONF state: USEISM
Wind: 5mph Gusts, 4mph 5min avg
Primary useism: 0.04 μm/s
Secondary useism: 1.24 μm/s
QUICK SUMMARY: H1 has been locked for just over an hour.
TITLE: 12/01 Owl Shift: 08:00-16:00 UTC (00:00-08:00 PST), all times posted in UTC
STATE of H1: Observing at 110Mpc
INCOMING OPERATOR: Cheryl
SHIFT SUMMARY:
Rough night. Previous aLogs contain details of the shift
LOG:
13:03 IA completed with no intervention
13:04 Attempt #1
13:15 Attempt #2
13:33 Attempt #3
13:36 Attempt #4
13:43 Attempt #5
14:08 Attempt #6
14:23 Attempt #7
14:56 NLN
15:00 H1 Observing
So, at my last mention of Initial Alignment, a lot has transpired.
10:04 I ran Initial Alignment
10:18 I attempted to re-lock
10:43 back to attempting to re-lock
10:57 Lockloss at TURN_ON_BS_STAGE2
11:00 Attempt #2
11:14 Attempt #3
11:47 Attempt #4
On another note:
As a matter of discovery:
A note on the 2.8W and searching for home:
The LASER_PWR node was complaining because it had to bootstrap the power too much (requesting 2.7W to get 2W => ~35% difference). Searching for home was the correct move here, and we haven't done this in quite some time. After searching for home via the medm, not the Guardian node, the node became confused. Requesting a different power and then back to 2W, as Ed did, is one way to solve this. The other to use the Search_For_Home state in LASER_PWR to aliviate some of the confusion.
Perhaps we should set up a consistent schedule to search for home on the rotation stage.
TITLE: 12/01 Owl Shift: 08:00-16:00 UTC (00:00-08:00 PST), all times posted in UTC
STATE of H1: Lock Acquisition
OUTGOING OPERATOR: Patrick
CURRENT ENVIRONMENT:
SEI_CONF state: WINDY
Wind: 9mph Gusts, 7mph 5min avg
Primary useism: 0.05 μm/s
Secondary useism: 0.75 μm/s
QUICK SUMMARY:
08:57 Y-ARM LOCKED in GREEN
So:
09:03 Lockloss @ ACQUIRE_DRMI_1F
Y arm still having trouble. It's locking on TEM00 but at a lower power now. Moving to Initial Alignment
TITLE: 12/01 Eve Shift: 00:00-08:00 UTC (16:00-00:00 PST), all times posted in UTC STATE of H1: Lock Acquisition INCOMING OPERATOR: Ed SHIFT SUMMARY: Lock loss cause not immediately apparent. Microseism is very high and likely making relocking difficult. LOG: 01:31 UTC Dropped out of observing by squeezer 01:33 UTC Hit INIT on SQZ_MANAGER 01:34 UTC Back to observing 06:23 UTC Lock loss 06:31 UTC Green arms not locking after 5 minutes. Starting manually alignment. Moved ETMX, ETMY, TMSY 06:42 UTC Lock loss from LOCKING_ALS Microseism is quite high 06:53 UTC Script moved to locking PRMI 07:08 UTC PRMI has not locked after 15 minutes. Trying CHECK_MICH_FRINGES. 07:12 UTC Moved BS in pitch. Retrying PRMI. 07:22 UTC PRMI not staying locked. Trying CHECK_MICH_FRINGES again. Moved BS in both pitch and yaw. 07:26 UTC Retrying PRMI. 07:30 UTC Lock loss from ACQUIRE_PRMI. 07:36 UTC Stopping at CHECK_IR, blue trace found too low. Adjust COMM and DIFF offsets. 07:40 UTC Attempting to lock PRMI 07:43 UTC PRMI locked 07:50 UTC Clicked OFFLOAD_DRMI_ASC to make guardian move on, then NLN 07:51 UTC DRMI locked 07:56 UTC Lockloss from CARM_OFFSET_REDUCTION 08:00 UTC Y arm is not locking on green. Ed taking over
Knocked out of observing briefly due to squeezer. No other issues.
TITLE: 11/30 Eve Shift: 00:00-08:00 UTC (16:00-00:00 PST), all times posted in UTC
STATE of H1: Observing at 113Mpc
OUTGOING OPERATOR: Cheryl
CURRENT ENVIRONMENT:
SEI_CONF state: WINDY
Wind: 8mph Gusts, 6mph 5min avg
Primary useism: 0.03 μm/s
Secondary useism: 0.42 μm/s
QUICK SUMMARY: No issues.
TITLE: 12/01 Day Shift: 16:00-00:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Observing at 114Mpc
INCOMING OPERATOR: Patrick
SHIFT SUMMARY: H1 locked in Observe all shift
LOG: