Carlos, Dave:
A new nuc (build name nuc25) has been installed as nuc5 in the control room (was renamed to nuc5). The old nuc was renamed to nuc25 so I could take files off it.
I've tested the kinit script generates a kerberos nuc5 robot ticket, and the dmtviewers are able to obtain data. My new startup script expands and starts the plots correctly. The new machine had its screen saver on, I've manually turned it off. Because it has the same name, the web links to its screenshots are operational.
Reminder, we are fixing the problem whereby one of the dmtviewers segfaults after a random period of time, anywhere from 7 minutes to over a day.
Sheila, Kara
We got a set of noise budget injections in while LLO was doing some commisioning, with the new PRCL FF, SRCL offset, and the curent spot positions.
We used a reference time of Sep 05 2019 22:31:51 UTC, we turned off the squeezer for a no squeezing reference at Sep 05 2019 23:06:57-23:17:00 UTC
We did a light set of injections, including PRCL, SRCL, MICH, intensity noise, frequency noise, IMC PZT P+Y, and CAHRD and DHARD. Results will be posted tomorow.
Here are the results of yesterdays noise budget injections when the squeezer was on. We are being limited by laser intensity noise at higher frequencies, which have gotten worse since our last noise budget (see Georia's alog 50104). In Georgia's alog, the shot noise was not correctly budgeted for. This is true in our noise budget as well, but it is not as obvious due to the increased intensity noise.
Shifter Terry McRae
LHO fellow Matthew Ball
For complete results see https://wiki.ligo.org/DetChar/DataQuality/DQShiftLHO20190826
TITLE: 09/05 Eve Shift: 23:00-07:00 UTC (16:00-00:00 PST), all times posted in UTC
STATE of H1: Observing at 115Mpc
OUTGOING OPERATOR: TJ
CURRENT ENVIRONMENT:
SEI_CONF state: WINDY
Wind: 11mph Gusts, 5mph 5min avg
Primary useism: 0.02 μm/s
Secondary useism: 0.14 μm/s
QUICK SUMMARY: locked in Observe, getting ready for some Commissioning time, cooincident with LLO.
TITLE: 09/05 Day Shift: 15:00-23:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Observing at 112Mpc
INCOMING OPERATOR: Cheryl
SHIFT SUMMARY: About to start commissioning. Started shift with a 5.9 earthquake off the coast of Oregon, had some ALS PZT bais issues, but we have been observing for 5 hours since.
LOG:
Jonathan, Carlos, Dave:
I've posted details in the FRS. I was able to see a segfault on one of the dmtviewers during testing this morning.
History:
Tue 3rd Sep 2019: maintenance, nuc5 upgraded from deb8 to deb9 (Carlos), launch.sh script modified to auto start dmtviewer and diaggui (Dave)
Tue 3rd Sep 2019: evening, Ed sees the FOM_STS dmtviewer crash.
Thu 5th Sep 2019: early hours, Travis sees the FOM_3-30Hz crash twice within hours
Thur 5th Sep 2019: Dave sees FOM_STS crash (segfault reported)
Carlos has been testing a dmtviewer (IFO range) on a new Nuc machine running a clean deb9 install in his office with no problems.
So, PLAN A is to upgrade nuc5 from its current old hardware with an upgraded deb9 to a new nuc with a clean deb9 install.
In the mean time, if a dmtviewer crashes, the easy way to restart it without having to reboot nuc5:
Get remote access to nuc5
xvncviewer nuc5
Open a terminal on the Desktop, and type
pkill dmtviewer
pkill diaggui
/home/controls/startup/launch.sh
FAMIS11507
No water was added to either chiller, both were near their max levels. Filters looked to be clear.
FAMIS10525
No water was added to the top or bottom. The "D" filter had some very slight darker discoloration toward the bottom of the filter, but perhaps the plastic was tricking me.
SDFs (in attachment order):
I forgot to mention that during initial alignment, MICH bright locked, but I left it in down for about 30seconds. It seemed to try to move out of down too fast.
TITLE: 09/05 Day Shift: 15:00-23:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Earthquake
OUTGOING OPERATOR: Travis
CURRENT ENVIRONMENT:
SEI_CONF state: EARTH_QUAKE
Wind: 6mph Gusts, 4mph 5min avg
Primary useism: 11.16 μm/s
Secondary useism: 16.36 μm/s
QUICK SUMMARY: 5.8 Mag earthquake off the coast of Oregon just knocked us out. BSCs have tripped, I wasn't able to get it into earthquake mode before we lost lock.
TITLE: 09/05 Owl Shift: 07:00-15:00 UTC (00:00-08:00 PST), all times posted in UTC
STATE of H1: Observing at 118Mpc
INCOMING OPERATOR: TJ
SHIFT SUMMARY:
LOG:
12:05 SEI Config to EQ mode for Iceland shaker
13:12 SEI Config back to WINDY
Near the beginning of my shift, I noticed that the 1-30Hz Seismic plots on NUC5 had disappeared. Since these now auto-start/arrange on restart, I decided to just boot the machine rather than fumbling with remote desktops. This worked . . . for a while. Now ~2 hours into my shift, the plots have again disappeared. Perhaps the startup script needs an update?
I'm investigating. This one is puzzling as this is one of two dmtviewers on this computer and there is no problem with the other dmtviewer, which kinda rules out a cert problem.
Laser Status:
Front End Power is 31.99W (should be around 30 W)
70W Output Power is 69.36W
Front End Watch is GREEN
70W Watch is GREEN
PMC:
It has been locked 6 days, 13 hr 13 minutes (should be days/weeks)
Reflected power = 10.53Watts
Transmitted power = 53.12Watts
PowerSum = 63.65Watts.
FSS:
It has been locked for 0 days 18 hr and 9 min (should be days/weeks)
TPD[V] = 4.887V (min 0.9V)
ISS:
The diffracted power is around 2.1%
Last saturation event was 0 days 18 hours and 12 minutes ago (should be days/weeks)
Possible Issues: None
TITLE: 09/05 Owl Shift: 07:00-15:00 UTC (00:00-08:00 PST), all times posted in UTC
STATE of H1: Observing at 117Mpc
OUTGOING OPERATOR: Cheryl
CURRENT ENVIRONMENT:
SEI_CONF state: WINDY
Wind: 3mph Gusts, 2mph 5min avg
Primary useism: 0.02 μm/s
Secondary useism: 0.19 μm/s
QUICK SUMMARY: Lock is 17 hours old with the past 7 in Observing. No issues to report.
TITLE: 09/05 Eve Shift: 23:00-07:00 UTC (16:00-00:00 PST), all times posted in UTC
STATE of H1: Observing at 117Mpc
INCOMING OPERATOR: Travis
SHIFT SUMMARY: calibrations, a brief exit for violins, locked in Observe the rest of the night
LOG:
Lower right dmtviewer (3-30Hz) just segfaulted, so problem maybe inherrent with deb9? Perhaps time to downgrade this machine back to deb8 for further testing.
actually there is no segfault dmesg for tonight's crashes. Looks like 3-30Hz dmtviewer has crashed at least twice in the past 5 hours.
Booted nuc5 at 12:39am and everything started fine, but the Upper Displays low-freq seismic DMT Viewer stopped running at 12:53am.