nuc5 computer replaced with new model, clean debian9 install

Carlos, Dave:

A new nuc (build name nuc25) has been installed as nuc5 in the control room (was renamed to nuc5). The old nuc was renamed to nuc25 so I could take files off it.

I've tested the kinit script generates a kerberos nuc5 robot ticket, and the dmtviewers are able to obtain data. My new startup script expands and starts the plots correctly. The new machine had its screen saver on, I've manually turned it off. Because it has the same name, the web links to its screenshots are operational.

Reminder, we are fixing the problem whereby one of the dmtviewers segfaults after a random period of time, anywhere from 7 minutes to over a day.

Comments related to this report
david.barker@LIGO.ORG - 17:11, Thursday 05 September 2019 (51762)

Lower right dmtviewer (3-30Hz) just segfaulted, so problem maybe inherrent with deb9? Perhaps time to downgrade this machine back to deb8 for further testing.

david.barker@LIGO.ORG - 22:09, Thursday 05 September 2019 (51765)

actually there is no segfault dmesg for tonight's crashes. Looks like 3-30Hz dmtviewer has crashed at least twice in the past 5 hours.

corey.gray@LIGO.ORG - 01:09, Friday 06 September 2019 (51769)

Booted nuc5 at 12:39am and everything started fine, but the Upper Displays low-freq seismic DMT Viewer stopped running at 12:53am.

H1 General
cheryl.vorvick@LIGO.ORG - posted 16:56, Thursday 05 September 2019 (51760)
H1 commissioning for about an hour
H1 AOS
sheila.dwyer@LIGO.ORG - posted 16:52, Thursday 05 September 2019 - last comment - 12:57, Friday 06 September 2019(51758)
noise budget injections

Sheila, Kara

We got a set of noise budget injections in while LLO was doing some commisioning, with the new PRCL FF, SRCL offset, and the curent spot positions. 

We used a reference time of  Sep 05 2019 22:31:51 UTC, we turned off the squeezer for a no squeezing reference at Sep 05 2019 23:06:57-23:17:00  UTC

We did a light set of injections, including PRCL, SRCL, MICH, intensity noise, frequency noise, IMC PZT P+Y, and CAHRD and DHARD. Results will be posted tomorow. 

Comments related to this report
kara.merfeld@LIGO.ORG - 12:57, Friday 06 September 2019 (51779)ISC
Here are the results of yesterdays noise budget injections when the squeezer was on.

We are being limited by laser intensity noise at higher frequencies, which have gotten worse since our last noise budget (see Georia's alog 50104).  In Georgia's alog, the shot noise was not correctly budgeted for.  This is true in our noise budget as well, but it is not as obvious due to the increased intensity noise.
Images attached to this comment
H1 DetChar (DetChar)
terry.mcrae@LIGO.ORG - posted 16:18, Thursday 05 September 2019 (51759)
DQ Shift: Monday 26 August 2019 00:00 UTC to Sunday 1 September 2019 23:59 UTC

Shifter Terry McRae

LHO fellow Matthew Ball

For complete results see https://wiki.ligo.org/DetChar/DataQuality/DQShiftLHO20190826

 

 

 

H1 General
cheryl.vorvick@LIGO.ORG - posted 16:04, Thursday 05 September 2019 (51757)
OPS Eve Transition:

TITLE: 09/05 Eve Shift: 23:00-07:00 UTC (16:00-00:00 PST), all times posted in UTC
STATE of H1: Observing at 115Mpc
OUTGOING OPERATOR: TJ
CURRENT ENVIRONMENT:
    SEI_CONF state: WINDY
    Wind: 11mph Gusts, 5mph 5min avg
    Primary useism: 0.02 μm/s
    Secondary useism: 0.14 μm/s
QUICK SUMMARY: locked in Observe, getting ready for some Commissioning time, cooincident with LLO.

LHO General
thomas.shaffer@LIGO.ORG - posted 16:01, Thursday 05 September 2019 (51750)
Ops Day Shift Summary

TITLE: 09/05 Day Shift: 15:00-23:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Observing at 112Mpc
INCOMING OPERATOR: Cheryl
SHIFT SUMMARY: About to start commissioning. Started shift with a 5.9 earthquake off the coast of Oregon, had some ALS PZT bais issues, but we have been observing for 5 hours since.
LOG:

H1 CDS
david.barker@LIGO.ORG - posted 11:46, Thursday 05 September 2019 (51756)
update on nuc5 investigation

Jonathan, Carlos, Dave:

I've posted details in the FRS. I was able to see a segfault on one of the dmtviewers during testing this morning.

History:

Tue 3rd Sep 2019: maintenance, nuc5 upgraded from deb8 to deb9 (Carlos), launch.sh script modified to auto start dmtviewer and diaggui (Dave)

Tue 3rd Sep 2019: evening, Ed sees the FOM_STS dmtviewer crash.

Thu 5th Sep 2019: early hours, Travis sees the FOM_3-30Hz crash twice within hours

Thur 5th Sep 2019: Dave sees FOM_STS crash (segfault reported)

Carlos has been testing a dmtviewer (IFO range) on a new Nuc machine running a clean deb9 install in his office with no problems.

So, PLAN A is to upgrade nuc5 from its current old hardware with an upgraded deb9 to a new nuc with a clean deb9 install.

In the mean time, if a dmtviewer crashes, the easy way to restart it without having to reboot nuc5:

Get remote access to nuc5

    xvncviewer nuc5

Open a terminal on the Desktop, and type

    pkill dmtviewer

    pkill diaggui

    /home/controls/startup/launch.sh

H1 TCS
thomas.shaffer@LIGO.ORG - posted 11:17, Thursday 05 September 2019 (51754)
TCS Chiller Weekly

FAMIS11507

No water was added to either chiller, both were near their max levels. Filters looked to be clear.

H1 PSL
thomas.shaffer@LIGO.ORG - posted 11:14, Thursday 05 September 2019 (51753)
Weekly PSL Chiller Reservoir Top-Off

FAMIS10525

No water was added to the top or bottom. The "D" filter had some very slight darker discoloration toward the bottom of the filter, but perhaps the plastic was tricking me.

H1 General (OpsInfo)
thomas.shaffer@LIGO.ORG - posted 11:00, Thursday 05 September 2019 - last comment - 11:24, Thursday 05 September 2019(51751)
Observing 1750 UTC

SDFs (in attachment order):

Images attached to this report
Comments related to this report
thomas.shaffer@LIGO.ORG - 11:24, Thursday 05 September 2019 (51755)

I forgot to mention that during initial alignment, MICH bright locked, but I left it in down for about 30seconds. It seemed to try to move out of down too fast.

H1 PSL
edmond.merilh@LIGO.ORG - posted 10:54, Thursday 05 September 2019 (51752)
PSL Weekly Report - 10 Day Trends FAMIS #10625
Images attached to this report
LHO General
thomas.shaffer@LIGO.ORG - posted 08:17, Thursday 05 September 2019 (51748)
Ops Day Shift Transition

TITLE: 09/05 Day Shift: 15:00-23:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Earthquake
OUTGOING OPERATOR: Travis
CURRENT ENVIRONMENT:
    SEI_CONF state: EARTH_QUAKE
    Wind: 6mph Gusts, 4mph 5min avg
    Primary useism: 11.16 μm/s
    Secondary useism: 16.36 μm/s
QUICK SUMMARY: 5.8 Mag earthquake off the coast of Oregon just knocked us out. BSCs have tripped, I wasn't able to get it into earthquake mode before we lost lock.

H1 General
travis.sadecki@LIGO.ORG - posted 08:01, Thursday 05 September 2019 (51747)
Ops Owl Shift Summary

TITLE: 09/05 Owl Shift: 07:00-15:00 UTC (00:00-08:00 PST), all times posted in UTC
STATE of H1: Observing at 118Mpc
INCOMING OPERATOR: TJ
SHIFT SUMMARY:
LOG:

12:05 SEI Config to EQ mode for Iceland shaker

13:12 SEI Config back to WINDY

H1 General (CDS)
travis.sadecki@LIGO.ORG - posted 01:52, Thursday 05 September 2019 - last comment - 08:26, Thursday 05 September 2019(51746)
NUC5 Seismic 1-30Hz plots go missing

Near the beginning of my shift, I noticed that the 1-30Hz Seismic plots on NUC5 had disappeared.  Since these now auto-start/arrange on restart, I decided to just boot the machine rather than fumbling with remote desktops.  This worked . . . for a while.  Now ~2 hours into my shift, the plots have again disappeared.  Perhaps the startup script needs an update?

Comments related to this report
david.barker@LIGO.ORG - 08:26, Thursday 05 September 2019 (51749)

I'm investigating. This one is puzzling as this is one of two dmtviewers on this computer and there is no problem with the other dmtviewer, which kinda rules out a cert problem.

FRS13541

H1 PSL (PSL)
travis.sadecki@LIGO.ORG - posted 01:06, Thursday 05 September 2019 (51745)
PSL Weekly Report

    Laser Status:
    Front End Power is 31.99W (should be around 30 W)
    70W Output Power is 69.36W
    Front End Watch is GREEN
    70W Watch is GREEN

    PMC:
    It has been locked 6 days, 13 hr 13 minutes (should be days/weeks)
    Reflected power = 10.53Watts
    Transmitted power = 53.12Watts
    PowerSum = 63.65Watts.

    FSS:
    It has been locked for 0 days 18 hr and 9 min (should be days/weeks)
    TPD[V] = 4.887V (min 0.9V)

    ISS:
    The diffracted power is around 2.1%
    Last saturation event was 0 days 18 hours and 12 minutes ago (should be days/weeks)


    Possible Issues: None

H1 General
travis.sadecki@LIGO.ORG - posted 00:10, Thursday 05 September 2019 (51744)
Ops Owl Shift Transition

TITLE: 09/05 Owl Shift: 07:00-15:00 UTC (00:00-08:00 PST), all times posted in UTC
STATE of H1: Observing at 117Mpc
OUTGOING OPERATOR: Cheryl
CURRENT ENVIRONMENT:
    SEI_CONF state: WINDY
    Wind: 3mph Gusts, 2mph 5min avg
    Primary useism: 0.02 μm/s
    Secondary useism: 0.19 μm/s
QUICK SUMMARY:  Lock is 17 hours old with the past 7 in Observing.  No issues to report.

H1 General
cheryl.vorvick@LIGO.ORG - posted 00:05, Thursday 05 September 2019 (51743)
OPS Eve Transition

TITLE: 09/05 Eve Shift: 23:00-07:00 UTC (16:00-00:00 PST), all times posted in UTC
STATE of H1: Observing at 117Mpc
INCOMING OPERATOR: Travis
SHIFT SUMMARY: calibrations, a brief exit for violins, locked in Observe the rest of the night
LOG:

Displaying reports 38841-38860 of 89074.Go to page Start 1939 1940 1941 1942 1943 1944 1945 1946 1947 End