ibrahim.abouelfettouh@LIGO.ORG - posted 23:39, Tuesday 21 October 2025 - last comment - 00:46, Wednesday 22 October 2025(87636)
OPS OWL Shift: DRMI Lock Issues

Got called at 11:15 PM (PT) due to IFO unable to lock DRMI. Ryan C had warned me before the end of his shift. The issue doesn't seem to be alignment since Initial Alignment was run 3 times over the course of the EVE shift and flashes look sufficient (if not great) to lock. I touched up the BS and PRM in PRMI to no avail. Requested MICH_FRINGES and we'll see if that helps the PRMI lock.

SEI_CONF is not in its nominal position but that seems intentional since the EY sensor correction was turned off today (alog 87634) due to an unrelated issue that happened during maintenance. 

In terms of microseism, it's high but it's not that high and we've locked at this level with higher winds in the past week. 

I will continue monitoring to see what happens but will resort to the call list if I'm not getting anywhere. I believe we've been unlocked for over 24 hrs now.

Comments related to this report
ibrahim.abouelfettouh@LIGO.ORG - 00:16, Wednesday 22 October 2025 (87637)

Called Jenne (first on call list) after managing to accomplish nothing. 

Flashes are good. Alignment is fine. DRMI is locking for 10s before unlocking due to what looks like environmental instability. It seems that 90th percentile+ microseism is just too high to lock - which doesn't make a lot of sense because we've locked with it at a similar level before. Since there aren't any glaring alignment or locking issues other than instability, we assumed it to be due to the environment.

Since microseism seems to be maybe going down slowly, advice given was to set IFO to lock automatically, and if it calls again, then I try again. If this becomes a cycle, then ~4/5 I was given the ok to put IFO in IDLE to avoid violin mode ringups (just like yesterday night). Be back soon (hopefully not).

ibrahim.abouelfettouh@LIGO.ORG - 00:28, Wednesday 22 October 2025 (87638)

Well, it seems that as soon as I was writing this, DRMI was conspiring against my statement and actually locked. We're now at PREP_DC_READOUT_TRANSITION. 

Getting "Low Recycling Gain" flashing during CARM but it (so far) has not caused a lockloss.

DHARD_P and Y look to be the noisiest signals currently. Let's see what happens.

ibrahim.abouelfettouh@LIGO.ORG - 00:46, Wednesday 22 October 2025 (87639)

Lockloss at MOVE_SPOTS with ASC signals oscillating wildly (warning of "waiting for ADS to converge"), same signal as the 4.5Hz MICH oscillation Ryan C reported during his shift. Confused what could be causing this. It seems like oscillating ASC and non-converging ASC were there throughout the lock acquisition. Querying the alog and wiki now. I've attached a screenshot of the oscillating signal, loudest in MICH during powerup ~25W to MAX_POWER

Images attached to this comment
H1 General
ryan.crouch@LIGO.ORG - posted 22:01, Tuesday 21 October 2025 (87635)
OPS Tuesday EVE shift summary

TITLE: 10/22 Eve Shift: 2330-0500 UTC (1630-2200 PST), all times posted in UTC
STATE of H1: Preventive Maintenance
INCOMING OPERATOR: Ibrahim
SHIFT SUMMARY: The furthest I've been able to get was MAX_POWER, I had several high state locklosses at different states (REDUCE_RF45, MOVE_SPOTS, MAX_POWER). I minimized the SHG rejected power while relocking as I saw the notification. After the second IA things went pretty well at first, microseism was still at about the same level as earlier. One of our locklosses at ALS had a BRS_GLITCH tag, which are rare. All of the LLs had an ADS_EXCURSION tag and most of the higher state locklosses I saw a ~4.5Hz oscillation in MICH. I started another IA at 21:45 as DRMI is taking a while to lock and it ran through CHECK_MICH on the last aquistion. Microseism has remained elevated and even increased a tiny bit. The IMC is really struggling to relock after INPUT_ALIGN, its been trying for the past 6 minutes as of 05:00.
LOG:                                                                                                                                                        

Start Time System Name Location Lazer_Haz Task Time End
22:43 PSL Keita Optics lab lOCAL ISS array 01:37
23:03 EE Marc, Fil MY n Replacing power supply 23:23
00:34 SEI Jim, Fil, Marc EndY N Check on BRS 01:00
H1 SEI
jim.warner@LIGO.ORG - posted 18:35, Tuesday 21 October 2025 - last comment - 09:06, Wednesday 19 November 2025(87634)
BRSY not damping like it should, bypassed, not used for now

Something happened with BRSY this morning during maintenance that caused it to ring up more than normal and now the damping is not behaving quite as expected. For now, I have paused the ETMY sensor correction guardian with the BRSY out of loop and turned off the output of the BRS so it won't be used for eq mode, should that transition happen.

So far today, I did a bunch of "recapturing frames" in the BRS C# code, which has usually fixed this issue in the past. We also restarted the beckhoff computer, then the plc, C# and epics ioc. This did not recover the BRS either. Marc, Fil and I went to EY and looked at the damping drive in the enclosure and I think it was behaving okay. When the drive came on, the output would reach ~1.8V, then go to 0V when it turned off.

I've contacted UW and we will take a look at this again tomorrow. 

Comments related to this report
jim.warner@LIGO.ORG - 13:32, Wednesday 22 October 2025 (87653)

Looked at this with Michael and Shoshana and the BRS is damped down now. Still not sure what is wrong but we have a theory that one side of the capacitive damper is not actuating. This seems to work okay when the velocities are either low or very high, but if they are moderate the high gain damping doesn't work well enough to get the BRS below a certain threshold, and instead keeps the BRS moderately rung up. We adjusted the damping on/off thresholds so the high gain damping will turn off at a higher velocities.

I will try to do some tests with it next week to see if we can tell if one side of the damper is working better than the other. For now, we should be able to bring the BRS back in loop.

thomas.shaffer@LIGO.ORG - 09:06, Wednesday 19 November 2025 (88169)

I've accepted these thresholds in SDF since it seems that this is the new normal.

Images attached to this comment
H1 SUS (SUS)
edgard.bonilla@LIGO.ORG - posted 18:23, Tuesday 21 October 2025 (87633)
Added option for v1 Pitch/Length OSEM estimator filters

Added an option to the OSEM estimator filters for PR3/SR3 that allows us to get v1 filters.

The v1 filters use the model at the first two L/P resonances of the SR3 and PR3 suspensions. [see images attached for an example of v2 vs v1]

The functions that construct these blends are the same ones posted in [LHO: 87613] and [LHO: 87596]:

blend_{PR3,SR3}_{length,pitch}v2_LP_est.m
The files must be run with the argument 'v1' to get the v1 filters out. For example, blend_PR3_lengthv2_LP_est('v1') will get the v1 filters for H1 PR3 in length.

If you run them with anything else (including no argument), they will get the v2 filters, same as before. However, I suggest running them as blend_PR3_lengthv2_LP_est('v2') in automated code so everything is clean for loading the filters into foton.

These changes have been committed to the SVN under revision 12745.

 

Images attached to this report
H1 SEI (CDS)
erik.vonreis@LIGO.ORG - posted 17:42, Tuesday 21 October 2025 (87632)
BRS EY restarted

[Jim, Jonathan, Erik]

BRS EY was restarted to try to damp high amplitude oscillations that started around 08:50 PDT.

We shutd down the processes in this order:

Epics

University of Washington process

TwinCAT PLC software

Then we restarted the server and started the same process in reverse order from desktop icons.

The restart did not have any apparent effect on the oscillations.

H1 General
matthewrichard.todd@LIGO.ORG - posted 17:37, Tuesday 21 October 2025 (87630)
IMC and Input jitter to ISS measurements

M. Todd, S. Dwyer


This morning we were not locked before Tuesday maintanence, so I skipped the HWS transient measurement and started immediately with the IMC and input jitter measurements I had planned. For posterity, the IFO was unlocked but the IMC was locked and input power taken to 62W, and then the ISS was turned on.

I continued attempting to tune injections of the IMC DOFs, but was not able to see any coherence to either the corresponding DOF error signal or the ISS loop, in the bands I was interested in. I think the DOF loop bandwidths are just tooo low for this kind of measurement without saturating the suspensions. I may continue to try some very small bands but nothing above 15 Hz anymore, as I'm just not convinced there is any reasonable coupling to the ISS there. The list of figures shows the injections from this injection set.

I then took some coherence measurements of the various sensors to the IMC ASC/LSC with the ISS loops during a quiet locked time to wrap my head around things better, and noticed a large coherence between the ISS first loop diodes and the ISS second loop witness sensor. I was initially confused by this but after talking with Keita, this is not surprising as there is most likely intensity noise that the 2nd loop is seeing and suppressing and thus imposing that suppression into the first loop sensors (thus the coherence).

Then I did some input jitter excitations, and without actually calculating the transfer functions ( those estimates will come later in a comment using Sheila's excess power code, due to the lack of coherence to ISS ) I don't think the ISS loops are limited by the input jitter at these frequencies. The list of figures shows the plots from this injection set.


List of Figures

  1. DOF_1_Y_IN1 during injection , ISS 2nd Loop RIN OUTER during injection
  2. DOF 3 P IN1 during injection, ISS 2nd Loop RIN OUTER during injection
  3. PZT P OUT during injectionISS 2nd Loop RIN OUTER during injection
  4. PZT Y OUT during injectionISS 2nd Loop RIN OUTER during injection
Non-image files attached to this report
LHO VE (VE)
gerardo.moreno@LIGO.ORG - posted 17:17, Tuesday 21 October 2025 (87631)
X-End BSC9 Annulus Ion Pump Status

Work done under WP 12845, used a ladder to get close to the ion pump body, and used a wrench to hit the body a couple of times.  Controller not railed after "fix".

Current dropped some at a very slow rate, but is not red anymore on the MEDM screen.

WP is closed now.

Images attached to this report
H1 CDS (PEM)
filiberto.clara@LIGO.ORG - posted 16:46, Tuesday 21 October 2025 (87628)
MY PEM AA Chassis

WP 12850

Chassis found with positive 15V LED powered off. Side rack 1A fuse was blown. Replaced shorted C12 capacitor on the first D070081 board. Chassis reinstalled.

LHO VE
jordan.vanosky@LIGO.ORG - posted 16:40, Tuesday 21 October 2025 (87619)
Quarterly Functionality Test Performed on EY/MY Turbo Pumps and Purge Air Skid
Procedure checklist for both stations completed.  No issues were identified at this time.

MY: Scroll pump hours: 98.5
       Turbo pump hours: 236
       Crash bearings: 100%

EY: Scroll pump hours: 89.9
       Turbo pump hours: 1297
       Crash bearings: 100%
 
Closing WP 12843 FAMIS 31280 and 31288
EY purge air compressor was ran for ~3 hours, dew point mointor quickly reached <-40 degF and at time of shut down was reporting -76 degF.

New system, so there are only a few run hours.

3 hours total, distributed between the three scroll compressors.
 
Images attached to this report
H1 General
oli.patane@LIGO.ORG - posted 16:36, Tuesday 21 October 2025 (87626)
Ops Day Shift End

TITLE: 10/21 Day Shift: 1430-2330 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Preventive Maintenance
INCOMING OPERATOR: Ryan C
SHIFT SUMMARY: Currently trying to relocking. Having some trouble, partially due to extremely high secondary microseism, and partly due to unknown issues.
LOG: 

14:30UTC Detector in IDLE due to high secondary microseism
20:47 Start relocking
    20:47 Initial alignment
    21:25 Initial alignment done
    Lockloss from LOWNOISE_LENGTH_CONTROL - ringup started when gains were changed, lost lock 10s later                                                                                                                                                                                                                                                                                                                                                                                    

Start Time System Name Location Lazer_Haz Task Time End
15:06 FAC Eric EX, EY n Lubricating fans 16:06
15:08 VAC Gerardo EX n Ion pump 15:44
15:09 VAC Jordan MY, EY n Turbo pump tests 18:35
15:15 FAC Kim, Nellie HAM Shack n Tech clean 16:08
15:19 FAC Tyler EX n Joining Eric 16:06
15:45 EE Fil LVEA n Swapping MC lower stage satamps 17:23
15:46 FAC Randy LVEA n Inspections 16:06
16:05 FAC Mitchell LVEA n Moving stuff to SEI rack 16:12
16:08 FAC Kim, Nellie LVEA n Tech clean 17:35
16:58 FAC Tyler LVEA, MX, MY n 3IFO checks 18:43
17:00 EE Marc LVEA n Joining Fil 17:06
17:08 SEI Jim, Randy LVEA n Looking around BSC2 17:59
17:24   Keita, Rahul OpticsLab y(local) ISS Array 19:48
17:31 EE Fil EX, EY n Checking out fibers and figuring out power supply issue 19:21
17:35 SEI Jim LVEA n Working on HAM7 SEI satamps 17:59
17:35 FAC Nellie EY n Tech clean 18:33
17:36 FAC Kim EX n Tech clean 19:23
17:36 EE Marc EX n Replacing failed fan 18:41
17:46 FAC Randy EY, EX n Checks 19:37
18:45 EE Marc EX n Get ready to restart EX pump controller 19:45
19:30 VAC Gerardo EY n Turning off purge air pumps 20:26
19:37 FAC Randy XTube n Caulking the tube 21:59
20:03   RyanC LVEA n Sweeping 20:26
21:49 EE Marc, Fil MY n Investigating PEM power supply failure 22:11
22:43 PSL Keita Optics lab lOCAL ISS array 23:43
23:03 EE Marc, Fil MY n Replacing power supply 23:23
H1 General
ryan.crouch@LIGO.ORG - posted 15:59, Tuesday 21 October 2025 - last comment - 16:49, Tuesday 21 October 2025(87621)
OPS Tuesday EVE shift start

TITLE: 10/21 Eve Shift: 2330-0500 UTC (1630-2200 PST), all times posted in UTC
STATE of H1: Preventive Maintenance
OUTGOING OPERATOR: Oli
CURRENT ENVIRONMENT:
    SEI_ENV state: USEISM
    Wind: 4mph Gusts, 1mph 3min avg
    Primary useism: 0.07 μm/s
    Secondary useism: 0.49 μm/s 
QUICK SUMMARY:

Comments related to this report
ryan.crouch@LIGO.ORG - 16:49, Tuesday 21 October 2025 (87627)PEM

Looking at the high 2ndary microseism it seems to be from the storm off west coast with wave swells of 10m and a swell period of 7.6sec ( ~0.13Hz). Something weird is that the MY seismometer had a big sudden jump in motion at ~23:10 UTC.

Images attached to this comment
H1 ISC
sheila.dwyer@LIGO.ORG - posted 15:53, Tuesday 21 October 2025 - last comment - 15:57, Tuesday 21 October 2025(87624)
gain scaling change reverted

I set the gain scaling back to use IMC INput power, since we had an unusual lockloss at LSC length control Elenna sees is related to LSC loop gain changes. 

This change should have made a 5% change in the loop gain, so if this was the reason for the lockloss one of our loops is very close to unstable.  

Comments related to this report
elenna.capote@LIGO.ORG - 15:57, Tuesday 21 October 2025 (87625)

Here is a scope showing the LSC loop ring up. The ring up started about 10s before lockloss which coincides with a few gains and filter changes in the LSC loops.

Images attached to this comment
H1 SUS
ryan.crouch@LIGO.ORG - posted 15:32, Tuesday 21 October 2025 (87622)
Weekly In-Lock SUS Charge Measurement FAMIS

Closes FAMIS28428, last checked alog87482.

Injections were not made as we were not locked this morning.

LHO VE (VE)
gerardo.moreno@LIGO.ORG - posted 10:59, Tuesday 21 October 2025 - last comment - 15:31, Tuesday 21 October 2025(87606)
X-End Noisy Power Supply

As I entered the VEA at X-End I noticed an out place noise, I tracked the noise source to be a noisy power supply at the vacuum rack.  Made the report to Filiberto and Richard, noise points to a fan issue.

Filed a FRS ticket, number 35689.

Non-image files attached to this report
Comments related to this report
david.barker@LIGO.ORG - 11:15, Tuesday 21 October 2025 (87607)

WP12849 Marc is replacing the old PowerTen DC power supply at EX. This supplies the Beckhoff vacuum controls for h0veex. It also supplies the Beckhoff HEPI Pump Controller chassis.

EDC lost 1197 channels when power supply was off (VAC and HPI_PUMPCTRL)

Vac is now back and burt restored at 11:10, we are working on getting the HEPI pump controller back.

marc.pirello@LIGO.ORG - 14:28, Tuesday 21 October 2025 (87618)

Power supply was replaced with Sorensen DCS33-33E supply.  Everything powered back up eventually, minor issues with the HEPI controller were solved.  This completes WP12849

F. Clara, R. McCarthy, G. Moreno, M. Pirello

daniel.sigg@LIGO.ORG - 15:31, Tuesday 21 October 2025 (87623)

HEPI controller did not come back on its own. This computer doesn't seem to be set up to start TwinCAT and tcioc automatically. Started both processes manually, but run into an issue that the TwinCAT system was running, but the PLC code was not. After recompiling the PLC code and loading it, the system finally came up.

H1 ISC
jennifer.wright@LIGO.ORG - posted 10:37, Friday 17 October 2025 - last comment - 15:38, Wednesday 26 November 2025(86744)
Optical Gain and output loss checks with hot OM2 on 4th September

Jennie W, Sheila,

 

I took a long time to post this as have been working on other things...

We carried out a test (see LHO alog #86785) to look at the effect of DARM offset stepping on the power at OMC-DCPD_SUMS and OMC-REFL (transmitted through and reflected from the OMC). We did this with the heater on OM2 off as is nominal.

We then meant to redo these measurements once we heated up OM2 to change the mode-matching of the IFO to the OMC.

Unbfortunately we lost lock at about 15:06 UTC while Corey was taking out first measurement before heating up the OM2.

The meausrement is shown in this image, I have mislabelled it as 'third measurement' but it was the first. The optical gain is shown just before this measurment to be 0.994.

Then we waited as long as we could under out initial parameters of being finished cooling the OM2 again by 1:45pm.

We took another measurement at 1 hr 25 mins into lock after two false starts where I forgot to turn off the ASC. The optical gain was measured right before we started the measurements to be 0.978 but was still thermalising.

And then we took a third 2 hrs 59 minutes into lock, the IFO should be thermalised but the temperature of OM2 was still trending upwards a bit. Optical gain was 0.986.

We can use the slope of the power at the antisymmetric port (P_AS) vs. the power at the DCPDs (P_DCPD) as the DARM offset changes to estimate the throughput of carrier through the OMC which allows us one estimate of the loss.

The plots of this throughput are here for the cold state (minus the points taken after we lost lock), here for the partially thermalised state, and here for the thermalised state.

I am also in the middle of using the plot of P_AS varying with power at the OMC reflected port (P_REFL) to get a better estimate of the mode-mis match between the interferometer and the OMC.

 

Images attached to this report
Non-image files attached to this report
Comments related to this report
jennifer.wright@LIGO.ORG - 12:33, Tuesday 21 October 2025 (87610)

I plotted the loss between the antisymmetric port (calibrated into the power entering HAM6) to the power on the DCPDs. This is the inverse of the slopes in the graphs above.

All three are poltted on one graph, using plot_AS_vs_DCPD_changes.py in my own cope of the labutils repository at /ligo/home/jennifer.wright/git/local_git_copies/labutils/darm_offset_step/ .

Sheila and Camilla both agreed the loss for the two bottom lines (purple and red) are too high. These imply that a hot OM2 gives us over 20 % output losses.

If we look at the increase in loss from cold OM2 to hot OM2 this is a factor of 2.1 (210 % increase).

Compared to the decrease in optical gain squared (which we expect to reflect the change in output losses, which was:

(0.986^2 - 0.994 ^2) / 0.994^2 = -0.016 (1.6 % decrease).

We might have to check the alignment of out optics was not changing while we changed the darm offset.

Non-image files attached to this comment
jennifer.wright@LIGO.ORG - 13:04, Tuesday 21 October 2025 (87614)

Looking at OM1, OM2 and SRM alignment it did change during the darm offset steps with the biggest change (in the third offsset step measurement) being in OM2 pitch and yaw, this is only a change around 6 microradians (Elenna and Jeff state this calibration in correct to within an order of magnitude). Not sure if this enough to invalidate the loss values we measure. OM3 and OMC sus did not change much but this is because IU purposely unlocked the OMC ASC while changing the darm offset.

Images attached to this comment
jennifer.wright@LIGO.ORG - 17:18, Tuesday 21 October 2025 (87629)

Jennie W, Matt T,

 

I plotted the antisymmetric power during the darm offset step vs. the power reflected by the OMC and am now very confused as the AS power looks to be smaller than the power reflected form the OMC. See the ndscope where I have zoomed in on the same time segment for both channels. The OMC-REFL channel is mean to be calibrated into mW and the ASC-AS_C channel is meant to be calibrated into W entering HAM 6 (even though the actual pick-off is the transmission through OM1).

The two plots attached show how the ratio between AS and OMC-REFL power changes during one of the DARM offset measurements we did right after I took this ndscope data.

Plot 1 hr 25 mins into lock.

Plot 2 hrs 59 mins into lock.

For each point the code returns the median of the time series at each step, this mioght be less valie for OMC-REFL as it is a lot noisier than ASC-AS_C.

I am still confused about the hogher power at OMC-REFL and wondering if:

a) I am confused about the calibration of one of these channels.

b) the calibration of one of these channels is wrong.

Images attached to this comment
Non-image files attached to this comment
jennifer.wright@LIGO.ORG - 15:38, Wednesday 26 November 2025 (88261)

I plotted the three measurements of P_AS vs. P_DCPD during thermalisation on the same plot to make them easier to compare.

The code for this is in /ligo/home/jennifer.wright/git/local_git_copies/labutils/darm_offset_step/plot_OMC_REFL_changes/P_as_vs_P_DCPD__comp_Sep_04.pdf

Non-image files attached to this comment