Reports until 04:01, Monday 08 July 2019
LHO General
patrick.thomas@LIGO.ORG - posted 04:01, Monday 08 July 2019 (50436)
Ops Owl Mid Shift Status
Have remained locked and in observing. No issues.
LHO General
patrick.thomas@LIGO.ORG - posted 00:13, Monday 08 July 2019 (50434)
Ops Owl Shift Transition
TITLE: 07/08 Owl Shift: 07:00-15:00 UTC (00:00-08:00 PST), all times posted in UTC
STATE of H1: Observing at 114Mpc
OUTGOING OPERATOR: Cheryl
CURRENT ENVIRONMENT:
    Wind: 18mph Gusts, 14mph 5min avg
    Primary useism: 0.08 μm/s
    Secondary useism: 0.14 μm/s 
QUICK SUMMARY: SEI_CONF to EARTH_QUAKE for incoming earthquakes.
H1 General
cheryl.vorvick@LIGO.ORG - posted 00:03, Monday 08 July 2019 (50433)
OPS Eve Summary

TITLE: 07/08 Eve Shift: 23:00-07:00 UTC (16:00-00:00 PST), all times posted in UTC
STATE of H1: Observing at 114Mpc
INCOMING OPERATOR: Patrick
SHIFT SUMMARY: locked all shift
LOG:

H1 General
cheryl.vorvick@LIGO.ORG - posted 21:42, Sunday 07 July 2019 (50432)
Mid-shift Update

Still locked, winds had dipped below 20mph, but are above that again.

Plot from my (first) ndscope file attached (.../nd_scope/ndscope_range_and_wind.yaml).

Images attached to this report
H1 General
cheryl.vorvick@LIGO.ORG - posted 16:23, Sunday 07 July 2019 (50431)
OPS Eve Transition

TITLE: 07/07 Eve Shift: 23:00-07:00 UTC (16:00-00:00 PST), all times posted in UTC
STATE of H1: Observing at 118Mpc
OUTGOING OPERATOR: Corey
CURRENT ENVIRONMENT:
    Wind: 7mph Gusts, 4mph 5min avg
    Primary useism: 0.04 μm/s
    Secondary useism: 0.09 μm/s
QUICK SUMMARY: locked in Observe

LHO General
corey.gray@LIGO.ORG - posted 16:21, Sunday 07 July 2019 (50425)
DAY Operator Summary

TITLE: 07/07 Day Shift: 15:00-23:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Observing at 115Mpc
INCOMING OPERATOR: Cheryl
SHIFT SUMMARY:

After all 3-detectors went down after the EQ, Virgo is still down and in a "troubleshooting" state.  Other than the big EQ, it was a fairly straightforward shift for the 2nd half of the shift. 
LOG:

H1 TCS (TCS)
corey.gray@LIGO.ORG - posted 15:02, Sunday 07 July 2019 (50430)
TCS Chillers FAMIS Task (#11499)

Addressed TCS Chillers (21:44-21:53utc)

H1 General
corey.gray@LIGO.ORG - posted 12:15, Sunday 07 July 2019 (50429)
Mid Shift Status: Back To OBSERVING!

Just after the noon hour (19:09utc), took H1 back to OBSERVING after the 7.1 EQ & rejoined L1.  Screenshot of SDF diffs which were all ACCEPTED is attached.

There were a handful of miniscule SDF diffs of 10^-10 or smaller.

There was also the usual ASC RF36 recurring diff we've had for the last couple of weeks.

Images attached to this report
H1 General
corey.gray@LIGO.ORG - posted 09:12, Sunday 07 July 2019 - last comment - 10:46, Sunday 07 July 2019(50427)
15:53 Lockloss Due to 7.1 EQ in South Pacific

Thought there was a chance we'd ride through this one as I watched signals get bigger and bigger over 30min, but as Seismon predicted, the R-waves did us in at exactly the time Seismon predicted they would!  Attached are screenshots of what I was looking at here in the Control Room.  Below is a timeline. 

Will wait it out with Green Arms or in the DOWN state as I wait for seismic waves/ringing to subside.

Images attached to this report
Comments related to this report
corey.gray@LIGO.ORG - 10:46, Sunday 07 July 2019 (50428)

Didn't really calm down until about 17:05, but even then locking wasn't great.  

In the middle of an alignment now.

LHO General
corey.gray@LIGO.ORG - posted 08:07, Sunday 07 July 2019 - last comment - 08:23, Sunday 07 July 2019(50424)
Transition to DAY Log

TITLE: 07/07 Day Shift: 15:00-23:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Observing at 114Mpc
OUTGOING OPERATOR: Patrick
CURRENT ENVIRONMENT:
    Wind: 13mph Gusts, 7mph 5min avg
    Primary useism: 0.02 μm/s
    Secondary useism: 0.08 μm/s
QUICK SUMMARY:

Smooth running with H1 going on a 26.5hr lock & BNS range hovering around 115Mpc.  Nice to see a calmer seismic picture over the last 24hrs with low winds. 

Comments related to this report
corey.gray@LIGO.ORG - 08:23, Sunday 07 July 2019 (50426)

D'oh.  Spoke too soon.  Have an incoming EQ (7.1 near Timore-Leste) listed as "large eq".  It is about 40min out for its R-Waves.  Will keep monitoring as it arrives.

LHO General
patrick.thomas@LIGO.ORG - posted 07:59, Sunday 07 July 2019 (50423)
Ops Owl Shift Summary
TITLE: 07/07 Owl Shift: 07:00-15:00 UTC (00:00-08:00 PST), all times posted in UTC
STATE of H1: Observing at 114Mpc
INCOMING OPERATOR: Corey
SHIFT SUMMARY: Remained locked and in observing entire shift. One GRB. One event candidate.
LOG:

07:23 UTC GRB E337958
Fermi 584176986
Standing down
INJ_TRANS already set to INJECT_KILL
Confirmed with LLO

09:34 UTC S190707q
Notified LLO and Daniel
LHO General
patrick.thomas@LIGO.ORG - posted 04:10, Sunday 07 July 2019 (50422)
Ops Owl Mid Shift Status
Have remained locked and in observing. No issues to report.
LHO General
patrick.thomas@LIGO.ORG - posted 00:14, Sunday 07 July 2019 (50421)
Ops Owl Shift Transition
TITLE: 07/07 Owl Shift: 07:00-15:00 UTC (00:00-08:00 PST), all times posted in UTC
STATE of H1: Observing at 90Mpc
OUTGOING OPERATOR: Cheryl
CURRENT ENVIRONMENT:
    Wind: 15mph Gusts, 10mph 5min avg
    Primary useism: 0.03 μm/s
    Secondary useism: 0.07 μm/s 
QUICK SUMMARY: No issues.
H1 General
cheryl.vorvick@LIGO.ORG - posted 00:04, Sunday 07 July 2019 (50420)
OPS Eve Summary:

TITLE: 07/07 Eve Shift: 23:00-07:00 UTC (16:00-00:00 PST), all times posted in UTC
STATE of H1: Observing at 117Mpc
INCOMING OPERATOR: Patrick
SHIFT SUMMARY: locked all shift, twice in SEI ISI Earthquake, winds at 30mph for a number of hours
LOG: all times UTC

LHO General
corey.gray@LIGO.ORG - posted 16:20, Saturday 06 July 2019 (50417)
DAY Operator Summary

TITLE: 07/06 Day Shift: 15:00-23:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Observing at 116Mpc
INCOMING OPERATOR: Cheryl
SHIFT SUMMARY:

Very nice shift for H1 with smooth running and only a small EQ which was not an issue at all.  Ended the shift with excitement from a possible BBH candidate with all three detectors online.
LOG:

H1 General
cheryl.vorvick@LIGO.ORG - posted 16:16, Saturday 06 July 2019 (50419)
OPS Eve Transition

TITLE: 07/06 Eve Shift: 23:00-07:00 UTC (16:00-00:00 PST), all times posted in UTC
STATE of H1: Observing at 117Mpc
OUTGOING OPERATOR: Corey
CURRENT ENVIRONMENT:
    Wind: 13mph Gusts, 9mph 5min avg
    Primary useism: 0.05 μm/s
    Secondary useism: 0.07 μm/s
QUICK SUMMARY: locked in Observe

LHO General
corey.gray@LIGO.ORG - posted 11:59, Saturday 06 July 2019 (50418)
Mid Shift Status

H1's been locked for 6+hrs.  Monitored a 5.1 EQ from New Zealand roll through, but did not need to take any action.

LHO General
corey.gray@LIGO.ORG - posted 08:30, Saturday 06 July 2019 (50416)
Transition to DAY Log

TITLE: 07/06 Day Shift: 15:00-23:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Observing at 116Mpc
OUTGOING OPERATOR: Patrick
CURRENT ENVIRONMENT:
    Wind: 6mph Gusts, 3mph 5min avg
    Primary useism: 0.01 μm/s
    Secondary useism: 0.08 μm/s

Somewhat quiet seismically with the CA 7.1 EQ 12hrs in the past.  Winds are calm. 
QUICK SUMMARY:

H1 humming along just under 120Mpc.  Something new from last time I was on shift a week ago are noisy periods for DARM blrms for the 500-1k & 1k-2k bands (attached) for multiple minutes at a time.

Images attached to this report