BS ST2 has a pair of peaks between 1-2 Hz. Note that we are currently in the EARTHQUAKE SEI configuration with an EQ ringing down, so not sure if this effects these spectra.
This spectra is taken some number of hours before the 'run' time, eight or something hours I'd guess. This puts this auto spectra right in the middle of a nearly four hour out of full IFO period where in the SEI BS will be in ISOLATED_DAMPED mode for potentially much of the time.
Addressed TCS Chillers (08:49 -08:57 PDT)
Transitioned to SEI EQ mode which kicks us out of Observing. Went back to Observing after transient SDFs cleared themselves.
Tagging @DetChar and SEI for data in seismic's sensor correction configuration transition studies. @DetChar -- the operators have been dilligently logging when they're transitioning from our nominal seismic sensor correction configuration to our earthquake configuration. Can y'all take a look at these times thus far in O3 and make and quantitative statements about how the change in configuration impacts the IFO and the searches? Similar question about the actual *transition,* with an eye towards answering the question "do we need to take the IFO out of observation ready to make the switch, or can we treat it like violin mode damping?" In order to facilitate this study, I'll take a moment to peruse past aLOGs and make sure DetChar and SEI have been tagged.
For longer term study, I've opened FRS Ticket 13123.
TITLE: 06/17 Day Shift: 15:00-23:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Observing at 112Mpc
OUTGOING OPERATOR: TJ
CURRENT ENVIRONMENT:
Wind: 7mph Gusts, 5mph 5min avg
Primary useism: 0.07 μm/s
Secondary useism: 0.06 μm/s
QUICK SUMMARY: Incoming 5.8 EQ from China. Will transition to SEI EQ mode soon. No other issues to report.
TITLE: 06/18 Owl Shift: 07:00-15:00 UTC (00:00-08:00 PST), all times posted in UTC
STATE of H1: Observing at 115Mpc
INCOMING OPERATOR: Travis
SHIFT SUMMARY: Recovery from the earthquake was nothing unsual. I was able to lock DRMI without issue but ASC would kill the lock, so I then went for an initial alignment. Relocking there was also pretty normal. Early in the morning Karen found a vistor asleep on site and the Sheriff was called. The vistor was taken away from the site in an ambulance.
LOG:
Squeezer lost lock, but then relocked quickly.
Tried to lock without an initial alignment, but DRMI would lose lock when engaging ASC. Ran an initial alignment and then suddenly lost lock at CARM ON TR, the FSS then took a bit of time to relock. Next attempt made it all the way.
Accepted ASC AS A RF 36 Q differences, not sure why they are different.
TITLE: 06/17 Owl Shift: 07:00-15:00 UTC (00:00-08:00 PST), all times posted in UTC
STATE of H1: Earthquake
OUTGOING OPERATOR: Ed
CURRENT ENVIRONMENT:
Wind: 18mph Gusts, 14mph 5min avg
Primary useism: 0.66 μm/s
Secondary useism: 0.11 μm/s
QUICK SUMMARY: Lost lock as I showed up from a 6.2 in Tonga. I will be relocking soon as the earth calms down.
TITLE: 06/17 Eve Shift: 23:00-07:00 UTC (16:00-00:00 PST), all times posted in UTC
STATE of H1: Earthquake
INCOMING OPERATOR: TJ
SHIFT SUMMARY:
Tonga EQ took us down. Handing off unlocked H1 to TJ.
LOG:
23:42 Dick G in with a new S.U.R.F. student
switched after 3 incoming warnings 6.2 from Tonga area. Intent bit was switched off and then on again.
not enough. Lockloss at n6:43 UTC.
Tagging @DetChar and SEI for data in seismic's sensor correction configuration transition studies.
TITLE: 06/16 Eve Shift: 23:00-07:00 UTC (16:00-00:00 PST), all times posted in UTC
STATE of H1: Observing at 115Mpc
OUTGOING OPERATOR: Travis
CURRENT ENVIRONMENT:
Wind: 19mph Gusts, 16mph 5min avg
Primary useism: 0.07 μm/s
Secondary useism: 0.06 μm/s
QUICK SUMMARY:
H1 Back to Observing 23:15UTC
TITLE: 06/16 Day Shift: 15:00-23:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Lock Acquisition
INCOMING OPERATOR: Ed
SHIFT SUMMARY: Nearly relocked at the end of shift.
LOG: See previous aLogs.
5.8 EQ from Tonga. Since I haven't had much luck transitioning to SEI EQ mode the past couple of days, and this being of borderline magnitude, I decided not to transition. Apparently that was the wrong choice.
Latency is 17125 seconds. Conferred with LLO and we will be ignoring this trigger.