Still locked, despite some increased wind (putting us at 82 hours). Received an alert for a BBH candidate with LLO (VIRGO down for maintenance) at 07:44 UTC.
Ops Shift Transition: 05/21/2019, Owl Shift 07:00 – 15:00 (00:00-08:00) - UTC (PT)
State of H1: Locked
Intent Bit: Observing
Weather: ~10 mph wind, cloudy sky
Primary 0.03 – 0.1Hz: 0.02 um/s
Secondary 0.1 – 0.3Hz: 0.2 um/s
Outgoing Operator: Travis
Quick Summary: Locked for 77 hours, continuous Observing for 5.5 hours. Seismon is partially back up.
TITLE: 05/21 Eve Shift: 23:00-07:00 UTC (16:00-00:00 PST), all times posted in UTC
STATE of H1: Observing at 113Mpc
INCOMING OPERATOR: Niko
SHIFT SUMMARY: Lock is 78 hours old with the past 5.5 hours in Observing. Nothing else to report.
LOG:
SEISMON errors
Earlier tonight we got verbal alarms and DIAG_MAIN messages about SEISMON connection errors. These errors cleared themselves after a while. However, when I attempted to use the EQ Response button for what I thought was an incoming EQ, it did not produce a plot. See attached screenshot of error message.
The errors were probably from me attempting to restart seismon remotely. I didn't think I was successful, but it seems I was, maybe it just took a little bit to recover? If the all of the epics variables were still wiped when Travis tried to run the eq response script, I'm not suprised it failed. But, it seems to be working again, now.
While mining for info, and posting here for recording, I stumbled on a note confirming that the ETM16 (the O3 ETMY optic) weighed in at 39,580g (with ears) during install into the suspension, which is consistent with what we measured in the lab prior to ear binding of 39,538g (add 22g per ear, 2 ears and you get 39,582g).
Squeezer lost lock, but relocked itself quickly. Back to Observing.
No more MC1 and MC3 glitches seen since the issues and reboots last Wed.
Trends of BOSEM channels since then are attached.
WED alog: https://alog.ligo-wa.caltech.edu/aLOG/index.php?callRep=49280
TITLE: 05/20 Eve Shift: 23:00-07:00 UTC (16:00-00:00 PST), all times posted in UTC
STATE of H1: Observing at 110Mpc
OUTGOING OPERATOR: Patrick
CURRENT ENVIRONMENT:
Wind: 12mph Gusts, 8mph 5min avg
Primary useism: 0.02 μm/s
Secondary useism: 0.16 μm/s
QUICK SUMMARY: Lock is 70 hours old with the past 8 hours in Observing.
TITLE: 05/20 Day Shift: 15:00-23:00 UTC (08:00-16:00 PST), all times posted in UTC STATE of H1: Observing at 110Mpc INCOMING OPERATOR: Travis SHIFT SUMMARY: Took out of observing while LLO was down to damp ITMX mode 8. Seismon is reporting an error. LOG: 15:04 - 15:07 UTC Out of observing to damp ITMX mode 8, setting gain to 10 20:35 UTC Kingsoft water in RO room in carpenter's shop 20:39 UTC Let Kingsoft water through gate 21:05 UTC Kyle to mid X 21:23 UTC Kyle back from mid X, going to mid Y 21:49 UTC Kyle back 21:53 UTC Sharan to optics lab
There is a message reporting SEISMON DEAD on the medm screen.
There is also a DIAG_MAIN message reporting: "SEISMON_EQ: Seismon system not updating"
There are instructions for restarting the seismon code on the wiki:
https://cdswiki.ligo-wa.caltech.edu/wiki/seismon
However, I tried restarting everything on both the seismon vm and h1fescript0 (only the epics ioc on screen 1690, checking that I didn't touch anything else, I hope) and the seismon screen is now blank, so I'm not sure what's up. Can't do much more remotely, but I think probably need to completely restart. Good thing tomorrow is maintenance.
DQ Shifter: Yanyan Zheng
LHO fellow: Sundae
Mentor: Beverly
For the more complete results see https://wiki.ligo.org/DetChar/DataQuality/DQShiftLHO20190513
Have remained locked and in observing since damping ITMX mode 8 this morning.
No SUS charge sign flip this week Will remain in laser hazard to allow troubleshooting of the GigE cameras, then transition to laser safe for vacuum team to take roamer arm measurements of H2 HAM chambers. SUS charge measurements, IM transfer functions, balun work and possibly Beckhoff troubleshooting will be deferred unless the IFO loses lock.
TITLE: 05/20 Day Shift: 15:00-23:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Observing at 111Mpc
OUTGOING OPERATOR: Niko
CURRENT ENVIRONMENT:
Wind: 7mph Gusts, 5mph 5min avg
Primary useism: 0.03 μm/s
Secondary useism: 0.16 μm/s
QUICK SUMMARY:
ITMX mode 8 was above 4. Since LLO was down I took the opportunity to take us out of observing to set its damping gain back to 10. We are back to observing and the mode is quickly damping now.
TITLE: 05/20 Owl Shift 07:00 – 15:00 (00:00-08:00), all times posted in UTC
STATE of H1: Observing
INCOMING OPERATOR: Patrick
SHIFT SUMMARY: Not much seismic activity or wind, one GRB 30 minutes before shift end. Locked for 62 hours, Observing for a little under 45 hours.
LOG:
07:00 (00:00) Start of shift
11:49 (04:49) Incoming 5.6 mag EQ from Chile
14:21 (07:21) GRB (E333565)
15:00 (08:00) End of shift
Still locked, wind has decreased and our range is somewhere around 111 Mpc. VIRGO relocked about 3 hours ago, and LLO has been locked for the last 17 hours, so we are in a triple-coincidence state.
Ops Shift Transition: 05/20/2019, Owl Shift 07:00 – 15:00 (00:00-08:00) - UTC (PT)
State of H1: Locked
Intent Bit: Observing
Weather: ~20 mph wind, clear sky
Primary 0.03 – 0.1Hz: 0.03 um/s
Secondary 0.1 – 0.3Hz: 0.3 um/s
Outgoing Operator: Jeff
Quick Summary: Locked for 54 hours, Observing for 37 hours. Increased wind has been affecting the range