Reports until 21:58, Friday 30 September 2016
H1 ISC
stefan.ballmer@LIGO.ORG - posted 21:58, Friday 30 September 2016 - last comment - 02:21, Saturday 01 October 2016(30131)
Various issues

We repeatedly had CHARD run away when switching to LOWNOISE_ASC. 

The investigation was not helped lockloss tool, which started crashing suddenly. Guaridan also started having issues (connection errors, white epics channels.)

 

 

Comments related to this report
jameson.rollins@LIGO.ORG - 02:21, Saturday 01 October 2016 (30134)

For partial explanation of the guardian issue see comment to next log.

I'm guessing that the issue with the lockloss tool might have been an overlong delay finding the latest lockloss times due to excessively verbose logging of the ISC_LOCK node when it's in connection error.  This mostly exposes the weakness of the lockloss tool relying on parsing the ISC_LOCK node logs for determining lockloss times, but secondarily points to the logs being maybe unnecessarily verbose under these particular connection error conditions.  If the lockloss tool problem was *not* due to a long wait time for returning the list of lockloss times, please let me know what the error was so that I can investigate.

I have an improved version of the lockloss tool that finds locklosses much faster via NDS.  I'll push it out after I push a minor guardian update on Tuesday.  It should make the lockloss tool much faster and more robust.

I also realize there's an issue with the log display part of the lockloss tool.  This is completely orthoganal issue to the plotting, and will also be fixed with the next guardian minor release.

Very sorry about the trouble.

H1 ISC
stefan.ballmer@LIGO.ORG - posted 21:21, Friday 30 September 2016 - last comment - 20:58, Monday 03 October 2016(30126)
Input beam Gouy Phase (for jitter investigations)

In an attempt to bring some clarity into the beam jitter discussion I looked at the Gouy phase evolution of the input beam. I collected distance and focal length information from a variety of sources, notably T1200470 and E1200616.

The biggest uncertainty I had was the PSL persicope to HAM1 viewport distance - if someone knows that, let me know.

The MATLAB script with all the numbers is in ~controls/sballmer/20160930/inputBeamCalc.m. It creates a structure of the following form, fully describing the beam and optical mode:

IMC =
    lambda: 1.0640e-06               % The wavelength in m
         q: 0.2325 +13.3832i          % The input Gaussian beam parameter q=z+izR in m
         N: 4                                 % number of optics
      dist: [16.2406 16.2406 0.2325 0.2325 0] % Distances between the optics (one more than N)
      ifoc: [0.0731 0 0 0]               % inverse focal length for all lenses and mirrors (f=R/2 for mirror)
     label: {'MC2'  'MC3'  'Waist'  'MC1'} % optic names
 

The attached .mat file contains the following structures of that form::

IMP:    Input beam: From PSL periscope to MC3
IMC:    Input Mode Cleaner
IMCp:  Input Mode Cleaner from MC1 to MC3 only (output path inside IMC)
IM:      Input Mirros: from IMC to PRM
PRC:  Power Recycling Cavity forward path
PRCr: Power Recycling Cavity return path
PRCrt:Power Recycling Cavity round trip

Below are plots and data for the different beam segments.

Non-image files attached to this report
Comments related to this report
stefan.ballmer@LIGO.ORG - 20:52, Friday 30 September 2016 (30127)

Input Mode Cleaner:

IMC =
    lambda: 1.0640e-06
         q: 0.2325 +13.3832i
         N: 4
      dist: [16.2406 16.2406 0.2325 0.2325 0]
      ifoc: [0.0731 0 0 0]
     label: {'MC2'  'MC3'  'Waist'  'MC1'}
       Pin: 50

z= 00.0000 m, Gouy phase: 00.0000 deg after passing MC1;   Spot size w=2.1293 mm
z= 16.2406 m, Gouy phase: 49.9133 deg after passing MC2;   Spot size w=3.3764 mm
z= 32.4812 m, Gouy phase: 99.8267 deg after passing MC3;   Spot size w=2.1293 mm
z= 32.7137 m, Gouy phase: 100.822 deg after passing Waist; Spot size w=2.129 mm
z= 32.9462 m, Gouy phase: 101.8172 deg after passing MC1; Spot size w=2.1293 mm
Round trip Gouy phase:  101.8172 deg

Gouy Phase from input coupler (MC1) to output coupler (MC3): 99.8267 deg

Images attached to this comment
stefan.ballmer@LIGO.ORG - 21:02, Friday 30 September 2016 (30128)

Input mirrors: From PSL periscope to MC3:

IM =
    lambda: 1.0640e-06
         q: -0.2325 +13.3832i
         N: 6
      dist: [0.2325 0.5507 1.0613 1.1703 1.2071 0.4130 0]
      ifoc: [0 0 0.1562 -0.3199 0 0.0409]
     label: {'Waist'  'IM1'  'IM2'  'IM3'  'IM4'  'PRMlens'}

z= 0.0000 m, Gouy phase: 0.0000 deg after passing MC3;         Spot size w=2.1293 mm
z= 0.2325 m, Gouy phase: 0.99527 deg after passing Waist;      Spot size w=2.129 mm
z= 0.78319 m, Gouy phase: 3.3516 deg after passing IM1;         Spot size w=2.1308 mm
z= 1.8445 m, Gouy phase: 7.8634 deg after passing IM2;           Spot size w=2.1444 mm
z= 3.0148 m, Gouy phase: 13.8099 deg after passing IM3;         Spot size w=1.7841 mm
z= 4.2219 m, Gouy phase: 19.9983 deg after passing IM4;         Spot size w=2.1257 mm
z= 4.6349 m, Gouy phase: 21.6763 deg after passing PRMlens; Spot size w=2.2471 mm
 

Images attached to this comment
stefan.ballmer@LIGO.ORG - 21:10, Friday 30 September 2016 (30129)

Input beam: From PSL periscope to MC3:

(The PSL periscope to input viewport distance is an educated guess.)

INP =
    lambda: 1.0640e-06
         q: -7.3931 +13.3832i
         N: 6
      dist: [0 2.7100 4.0180 0.2118 0.1400 0.2563 0.2895]
      ifoc: [0 0 0 0 0 0]
     label: {'PSLperiscope'  'INPUTViewPort'  'PeriscopeTop'  'PeriscopeBottom'  'Steer1'  'Steer2'}
 

z= 0 m, Gouy phase: 0 deg after passing PSLperiscope;                       Spot size w=2.4323 mm
z= 2.71 m, Gouy phase: 9.6308 deg after passing INPUTViewPort;         Spot size w=2.2556 mm
z= 6.728 m, Gouy phase: 26.0719 deg after passing PeriscopeTop;        Spot size w=2.1316 mm
z= 6.9398 m, Gouy phase: 26.9771 deg after passing PeriscopeBottom; Spot size w=2.1302 mm
z= 7.0798 m, Gouy phase: 27.5759 deg after passing Steer1;                Spot size w=2.1296 mm
z= 7.3361 m, Gouy phase: 28.6729 deg after passing Steer2;                Spot size w=2.129 mm
 

Images attached to this comment
stefan.ballmer@LIGO.ORG - 21:15, Friday 30 September 2016 (30130)

Power Recycling Cavity:

PRCrt =
    lambda: 1.0640e-06
         q: 7.1228 + 5.2551i
         N: 8
      dist: [16.6128 16.1551 24.8880 0 0 24.8880 16.1551 16.6128 0]
      ifoc: [-0.4391 0.0556 -2.3189e-04 -0.0010 -2.3189e-04 0.0556 -0.4391 -0.1818]
     label: {'PR2'  'PR3'  'ITMlens'  'ITMback'  'ITMlensr'  'PR3r'  'PR2r'  'PRM'}

z= 00.0000 m, Gouy phase: 00.0000 deg after passing PRM;      Spot size w=2.2471 mm
z= 16.6128 m, Gouy phase: 23.9355 deg after passing PR2;       Spot size w=6.1716 mm
z= 32.7679 m, Gouy phase: 24.8769 deg after passing PR3;       Spot size w=53.9602 mm
z= 57.6559 m, Gouy phase: 25.0458 deg after passing ITMlens;  Spot size w=52.9743 mm
z= 57.6559 m, Gouy phase: 25.0458 deg after passing ITMback; Spot size w=52.9743 mm
z= 57.6559 m, Gouy phase: 25.0458 deg after passing ITMlensr; Spot size w=52.9743 mm
z= 82.5438 m, Gouy phase: 25.2148 deg after passing PR3r;      Spot size w=53.9602 mm
z= 98.6989 m, Gouy phase: 26.1562 deg after passing PR2r;      Spot size w=6.1716 mm
z= 115.3117 m, Gouy phase: 50.0916 deg after passing PRM;    Spot size w=2.2471 mm
Round trip Gouy phase: 50.0916 deg (one-way Gouy phae: 25.0458 deg)

Images attached to this comment
jeffrey.kissel@LIGO.ORG - 09:34, Monday 03 October 2016 (30168)SYS
I see you've used 2.71 [m] as your distance between the PSL periscope an the HAM1 viewport, and mentioned this was a big uncertainty.

If I take the corner station Rack/Cable tray layout D1002704, which tells the distance between the HAM1 viewport and the +X edge of the PSL table is 86 [in], and add it to the distance from the edge of the table to the periscope mirrors from D0902114 -- 14 [in] -- I get an even 100 [in].

Thus, 2.54 [m] is likely a better number.

I tag Systems just in case they have an even more accurate/precise number, but I think past the ~inch level precision, we'd need to measure it.
cheryl.vorvick@LIGO.ORG - 20:58, Monday 03 October 2016 (30196)
T1000696-v2 PSL table to HAM1 door flange 88in
T1000696-v2 HAM door depth 18in
picture top periscope mirror to edge of table 14in
total top periscope to input viewport 84in, 2.134m 

T1000696-v2 has verified distances.

D1002704 is measuring PSL table North edge to HAM1 door flange, and states it's 86 inches.

D1102219-v1, Micheal Rodruck's document, aptly named H1_table_v1.pdf, has what I believe are measured values, though not in a form that's easy to use, but what I've looked at is consistant with T1000696-v2.

Using this combination of documents, the outer PSL wall to the input viewport is calculated to be 70 inches, something that could easily be measured.

Non-image files attached to this comment
H1 General
edmond.merilh@LIGO.ORG - posted 20:45, Friday 30 September 2016 (30125)
Mid Shift Summary - Eve
H1 ISC
keita.kawabe@LIGO.ORG - posted 19:06, Friday 30 September 2016 - last comment - 11:15, Friday 07 October 2016(30124)
Jitter coupling model via BS wedge: Plausible but unclear

BS horizontal wedge doesn't have any couterpart Y path. Any horizontal beam shift on the BS will cause MICH path difference because of this wedge.

(CPY has a horizontal wedge but it's a mirror image of CPX about BS HR surface. ITMY has a vertical wedge but again it's a mirror image of ITMX.)

This effect doesn't look small, and a rough calculation shows that the HPO jitter peaks from DBB (but not broad humps seen in DBB) are consistent with what we see in DARM.

----

In the attached cartoon, when the beam on the BS is shifted in Y direction by y (blue line), the optical single-trip distance from the beam spot on the BS to ITMX gets shorter than to ITMY by:

EQN1: MICH = n*yW*sqrt(2)/cos(theta) - yW*(1+tan(theta)) ~ 0.7896yW = 1.0E-3*y

where W=1.3E-3 rad is the wedge, n=1.4496 is the refractive index and theta=29.2deg=0.5096rad is the angle of refraction.

DARM will only see about (1-rI)/(1+rI) of MICH where rI is the amplitude reflectivity of the ITMs, which is sqrt(0.986):

EQN2: DARM=MICH*(1-rI)/(1+rI) = 3.5E-3*MICH ~ 3.5E-6 * y.

Because of this, DARM should have a flat coupling to YAW displacement on BS.

Instead of the displacement y, we'll use the displacement A which is just the displacement normalized by the beam radius on the BS (53.4mm):

EQN3: DARM=3.5E-6*53.4[mm]*A = 1.9E-7 [m] * A.

----

Now, let B be a normalized misalignment parameter out of HPO (i.e. HPO jitter), e.g. B=disp/waistRadius+ i* angle/divAngle. Note that abs(B) is conserved unless 01/00 mode ratio is altered.

PMC gives us 1.6% HOM01 suppression in amplitude (T0900616).

For IMC there's some difference for PIT and YAW due to additional sign flip on top of Gouy shift per round trip, but PIT suppression is about 0.5% and YAW is 0.4% in amplitude assuming that the common round trip Gouy shift is 102 deg.

For PRC, assuming carrier recycling gain of 30, PRM reflectivity of 97% and the round trip Gouy shift of 32.5 deg, HOM01 suppression is 5.7% in amplitude.

PMC, IMC and PRC combined, HOM01 suppression is 3.7e-6 for YAW, 4.6e-6 for PIT.

Though A cannot be known without knowing the Gouy shift from HPO to BS, since |B| is conserved except through cavities, we can set the upper bound on |B| using the HOM suppression through PMC, IMC and PRC as

EQN4: |A| < 3.7e-6 * |B|

therefore upper bound on DARM

EQN5: DARM < 7E-13 [m] * |B|.

DBB measurements of B are available in alog, e.g. alog 29754 (direct link to the HPO jitter plot is here).

If you look at 1kHz peak which does not appear in DBB RIN measurement, the peak height is somewhere between 5E-6 to 1E-5, and using EQN5 and these numbers,

EQN6: DARM < 3.5 to 7E-18 [m/sqrtHz] at 1kHz peak.

In DARM spectrum, 1kHz peak is visible at or somewhat above 1E-19 [m/sqrtHz], so it seems consistent with EQN5.

----

Caveats:

IF the broad noise in DBB jitter measurement is actually jitter,  assuming the same jitter coupling as the above, you should see the huge broad thing in DARM, which we do not.

This coupling only applies to YAW. As for PIT, there could be similar coupling mechanism if ITM wedges don't cancel with each other, but the imbalance is only 0.001 degree.

MICH is not the only thing that is modulated by this, SRCL and PRCL are simultaneously modulated. Full simulation might be useful.

Images attached to this report
Comments related to this report
keita.kawabe@LIGO.ORG - 11:15, Friday 07 October 2016 (30307)

Update: Wrong.

If you do the correct calculation there's no differential phase change (see attached). In the above entry I ignored the fact that BS transmission is deflected relative to the incident.

Images attached to this comment
H1 TCS
edmond.merilh@LIGO.ORG - posted 18:48, Friday 30 September 2016 (30123)
Added water to TCS chillers

I added ≈100mL to the TCSY chiller .  Attached are pics of BOTH levels BEFORE water was added. (TCS_1569.jpg is TCSY).

Images attached to this report
H1 CAL (CAL, DetChar, ISC, PSL)
jeffrey.kissel@LIGO.ORG - posted 18:24, Friday 30 September 2016 (30122)
Recent 15 Mpc Gain from CSOFT ASC Offsets Are Real
J. Kissel

Now that we have updated EPICs records that store the DARM loop model (LHO aLOG 29992), I wanted to confirm the Nutsinee's recent 15 Mpc BNS range gain (LHO aLOG 30085)was not because the calibration of the DARM response was changing. I've confirmed the gain is not because the calibration has changed. I also wanted to sanity check the new DARM model parameter time dependence channels (LHO aLOG 29855). I'm sure if I trust them yet; we still need a comparison against offline calculations of the same thing (aka "SLM Tool").

See all of the attachments.
Plot (2) -- Recreates her picture of the BNS range trend over 24 hours. Note that the two times I compare are shown with vertical lines on the dataviewer trace in 
   - red (1159272420, Sep 30 2016 12:06:43 UTC, Sep 30 2016 05:06:43 PDT) and in 
   - magneta (1159270000, Sep 30 2016 11:26:23 UTC, Sep 30 2016 04:26:23 PDT).

Plot (1) -- Recreates her ASD, at the above mentioned times. This shows the full spectrum, and the drastic difference in noise performance between the two times.

Plot (3) -- This shows the same ASD comparison, but zoomed in around the calibration line frequencies, all generated by PCALY, and read out in the calibrated reflected PD, or RXPD. This qualitatively shows that there's very little change in the line heights at any of the line frequencies.

Plot (4) -- This shows the magnitude and phase of the transfer function between PCAL and DELTA L EXTERNAL in (m/m) around the low frequency calibration lines; 7.93 and 36.7 [Hz]. At the calibration line frequencies, we can see a change of at most 5% and 3 [deg]. This is about the uncertainty in the overall calibration anyways (though this has not yet been officially quantified for the current state of the instrument). This is encouraging, with respect to the SRC detuning optical spring -- whatever detung we have appears to be unimpacted by these alignment changes. A *much* more rigorous study than two points of one lock stretch should be done, however.

Plot (5) -- Same as plot 5, but for the high frequency calibration lines; 331.9 and 1083.7 Hz. We see similarly little change in these magnitudes and phases.

Plots (6-9) -- These show trends of the optical gain, cavity pole, and the actuation strength of the QUAD compared against the BNS range over the 4 hour period in which Nutsinee was playing. While there is a clear correlation between the cavity pole and optical gain against the BNS range, I'm not sure I believe that the cavity pole has changed by 30 [Hz] given such little change in magnitude and phase of the 331.9 [Hz] line. Again, a *much* more rigorous, offline comparison should be done between these values which are calculated from the calibration line amplitudes and phases.
Images attached to this report
H1 IOO (IOO)
cheryl.vorvick@LIGO.ORG - posted 18:19, Friday 30 September 2016 (30116)
PMC waist to IM1 - distances in meters - focal lengths and ROCs in the attached file
  meters from PMC waist
IO mode matching lens 1 0.78
IO mode matching lens 2 0.84
bottom of periscope 2.301
beam as it leaves the table 3.484
input viewport, HAM1 5.262
MC1 AR 10.055
MC1 HR 10.178
MC2 26.418
MC3 HR 42.659
MC3 AR 42.781
IM1 43.210
Non-image files attached to this report
H1 AOS (SEI, SUS)
edmond.merilh@LIGO.ORG - posted 18:05, Friday 30 September 2016 (30121)
Optical Lever 7-Day Trends FAMIS #4695
Images attached to this report
H1 ISC
daniel.sigg@LIGO.ORG - posted 17:04, Friday 30 September 2016 - last comment - 11:26, Tuesday 04 October 2016(30119)
Jitter into the IMC

This is a plot of the jitter measured by the IMC WFS DC PIT/YAW sensors during last nights lock. The 280 Hz periscope peak reaches about 1x10-4/√Hz in relative pointing noise, or about 3x10-4 rms. The relative pointing noise out of the HPO is about 2x10-5/√Hz at 300 Hz. After the attenuation through the PMC this would correspond to a level below 10-6/√Hz. The jitter peaks show up in DARM, if they are high enough. This is clearly visible in the coherence spectra.

The ISS second loop control signal is an indication of the intensity noise after the mode cleaner with only the first loop on. The flat noise level above 200 Hz is around 3x10-6/√Hz in RIN, with peaks around 240 Hz, 430 Hz, 580 Hz and 700 Hz. Comparing this to the free-running noise in alog 29778 shows this RIN level at 10^-5/√Hz. We can also compare this with the DBB measurements, such as in alog 29754: the intensity noise after the HPO shows a 1/f behaviour and no peaks. Looking at the numbers it explains the noise below 300 Hz. It looks like a flat noise at the 10^-5 level including the above peaks gets added to the free-running intensity noise after the PMC. The peaks in the controls signal of the second loop ISS line up with peaks visible in the pointing noise. But, neither the numbers nor the spectral shape matches. These peaks have coherence with DARM.

Non-image files attached to this report
Comments related to this report
daniel.sigg@LIGO.ORG - 10:30, Monday 03 October 2016 (30169)

Checking the calibration of the WFS DC readouts I noticed a calibration error of a factor of 0.065. So, all angles measured by the WFSs should be scaled by this number. This still makes the jitter after the PMC dominant, but one might expect to see some of the HPO jitter peak show through in places where the downstream jitter has a valley. In any case, we should repeat the PSL jitter measurement with the IMC unlocked.

Non-image files attached to this comment
daniel.sigg@LIGO.ORG - 11:26, Tuesday 04 October 2016 (30206)

A report of the measured beam jitter at LLO is available in T1300368.

An earlier measurement at LHO is reported in alog 21212. Using an IMC divergence angle of 1.6x10–4 rad, the periscope peak at 280 Hz is around 10^-4/√Hz. This is closer to the first posted spectrum with the "wrong" calibration. Here I post this spectrum again and add the dbb measurement of the jitter out of the HPO propagated through the PMC (1.6%), but scaled by a fudge factor of 2. The Sep 11, 2015, spectrum shows a more or less flat noise level below 80 Hz, whereas the recent spectrum shows 1/f noise. The HPO spectrum also shows as 1/f dependency and is within a factor of 2 of the first posted spectrum. If jitter into the IMC is the main coupling mechanism into DARM, the HPO jitter peaks above 400 Hz are well below the PSL table jitter after the PMC and the would not show up in the DARM spectrum.

Non-image files attached to this comment
H1 ISC
kiwamu.izumi@LIGO.ORG - posted 16:55, Friday 30 September 2016 - last comment - 11:15, Monday 03 October 2016(30115)
Spectral shape of the noise we are tyring to hunt

I have done a cross correlation analysis of the two OMC DCPDs in order to study the spectral shape of the broad band noise that has been limiting the sensitivity in 200-1000 Hz band. Here are some results.

The red curve is cross-correlated noise of the two DCPDs in terms of the DCPD current in mA (with DARM loop effect removed).The data I used is a lock stretch from Sep. 26th which lasted for 6 hours in undisturbed. The frequency resolution or bandwidth is set to 0.1 Hz. The data length is 3 hours starting at 9:00:00 UTC of the day. The DARM suppression is taken out from OMC DCPD SUM. I have used the latest PreER10 DARM model (29931) to obtain a reasonable DARM suppression function. As we all know, there is high noise in 200-1000 Hz whose level is as high as shot noise (or null stream shown in green) in this frequency band.

I also made another plot, which is an overlay of 11 cross correlated spectra each of which is from different time but from the same lock stretch. See below.

This time, the frequency resolution is set to 1 Hz, so that we can get several FFTs out of the same lock stretch. Each spectrum is produced by an 18 minutes integration. As shown in the plot, there was one spectrum which is polluted by some kind of glitch. Otherwise, the shape of noise stayed almost unchanged over 3 hours. Also fig files are available.

Images attached to this report
Non-image files attached to this report
Comments related to this report
kiwamu.izumi@LIGO.ORG - 11:15, Monday 03 October 2016 (30176)

There was a question of whether the cross-spectrum noise was from readout electronics or not. I have checked it by looking at dark noise from this past weekend in which laser happened to be off.

I conclude that the excess noise we see at around 400 Hz is not from dark noise or similar readout noise. In fact the dark noise level above 100 Hz was found to be consistent with a measurement a year ago (20526). Things look good to me. The attached is a plot of the dark noise spectra.

DCPD settings:

  • First stage of the whitenings is engaged.
  • High-Z (400 Ohms)
Images attached to this comment
H1 PSL
edmond.merilh@LIGO.ORG - posted 16:46, Friday 30 September 2016 - last comment - 17:37, Friday 30 September 2016(30118)
PSL tripped off

@ ≈23:45 UTC

Comments related to this report
edmond.merilh@LIGO.ORG - 17:37, Friday 30 September 2016 (30120)

The Diode Chiller was in error - Flow Sensor 1. With Jason's phone guidance I was able to restart the LASER with no issues. The thought is that this is a pre-cursor to a control panel failure on the Diode chiller. I was informed by Jason that there is one on it's way. It should be here some time late next week.

H1 General
edmond.merilh@LIGO.ORG - posted 16:10, Friday 30 September 2016 (30114)
Shift Summary - Eve Transition
 
 
TITLE: 09/30 Day Shift: 15:00-23:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Commissioning
OUTGOING OPERATOR: None
CURRENT ENVIRONMENT:
    Wind: 7mph Gusts, 3mph 5min avg
    Primary useism: 0.02 μm/s
    Secondary useism: 0.11 μm/s 
QUICK SUMMARY:
LHO General (OpsInfo)
corey.gray@LIGO.ORG - posted 16:07, Friday 30 September 2016 (30113)
Shift Summary

Summary:  Morning was spent recovering from Power Glitch.  Afternoon H1 was handed over for Commissioning.  Here are some notable activities from shift:

Notes:

Locking Notes:

H1 CDS (DAQ)
david.barker@LIGO.ORG - posted 15:08, Friday 30 September 2016 (30112)
CDS model and DAQ restart report, Thursday 29th September 2016

model restarts logged for Thu 29/Sep/2016
2016_09_29 03:35 h1nds0
2016_09_29 14:10 h1nds0
2016_09_29 14:27 h1nds0
2016_09_29 14:32 h1nds0

installed more memory in h1nds0 to make it the same as h1nds1, no further unexpected restarts of h1nds0 for the rest of the day (and none on Friday at time of writing).

LHO VE
chandra.romel@LIGO.ORG - posted 13:55, Friday 30 September 2016 - last comment - 16:45, Friday 30 September 2016(30108)
CP4 experiment
Overfilled CP4 again:

1. Opened exhaust bypass valve
2. Doubled LLCV (66% open)
3. Took ~17 min. to fill reservoir from 92% to 100%.
4. Took another hour to see LN2 pour out the exhaust. 
5. TC 252B did not respond to temp. change (and I broke the other one yesterday)
6. Set LLCV to nominal at 32% open in manual mode after the overfill
7. Would like to see how long it takes CP to recover to 92% at nominal LLCV (but may not happen this time since it's the weekend)

I used the borescope to look at the TC junction on the exhaust to see if it's measuring the pipe or the fluid flow. I couldn't see much but I suspect it's measuring just the pipe since the time delay on CP3 is long and temps never drop below -12degC on CP3 (response is faster when heating pipe with heat gun). 

I would like to drill and tap TCs directly into the pipe and use the existing signal lines to measure a more direct temp. for CP3 automation.

Images attached to this report
Comments related to this report
chandra.romel@LIGO.ORG - 13:59, Friday 30 September 2016 (30109)
Attached is temp and pressure trend for a CP3 overfill
Images attached to this comment
chandra.romel@LIGO.ORG - 16:45, Friday 30 September 2016 (30117)
CP4 is now in PI mode with lower limit set to 32%. Need to set this back to 20% on Monday. Want to see how long it takes to fall to 92% full at this nominal value.